MAURY USCG vessel records
← All vessels

BY THE WAY

BY THE WAY is a 2020 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2020, most recently in December 2025, along with 19 deficiencies.

Records from 2020 to 2025. Most recent: inspection, 3 December 2025.

Built
2020
Last inspected
3 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDL6999
1602542
Flag
UNITED STATES
Maury page id
psix-1602542

Inspections, by type

Years with a record 6 calendar years (2020–2025)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2020
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Net Ton
29 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 11

3 December 2025 Examination of Repairs · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8276648
24 June 2025 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8160382
11 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7999945
11 December 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7833973
20 September 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7782411
23 December 2022 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7612409
21 September 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7543172
6 December 2021 Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7363287
13 September 2021 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7311010
19 August 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7037191
1 July 2020 Simplified Stability Test · Initial Certification · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6994540

Deficiency record · 19

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 June 2025 Resolved
Each hatch exposed to the weather must be watertight. Forward collision bulkhead and stern steering compartment hatches are exposed to the weather, and found not to be watertight during hydro-test. 46 CFR 174.220 Code 17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2025
Resolution: Corrected on the spot by adjusting the hatches.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 June 2025 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are suitable condition and fit for the service intended. Steering hydraulic ram was found to be leaking hydraulic fluid through seals, and the fittings of the hydraulic hoses were found corroded. 46 CFR 176.814 Code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 23 July 2025
Resolution: New seals have been installed in the hydraulic bottle, and new fittings installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 24 June 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 3 July 2025
Resolution: New EAP Placard for 2025 installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 June 2025 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Top Jim-buoy type life-float was found fractures and peeling-off. Conduct proper repairs. 46 CFR 180.175 Code 50C.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2025
Resolved 30 July 2025
Resolution: A coat of vinyl was applied to the fractured surfaces, extending its serviceable life to 1 or thee years.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 September 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Audio and visual high water bilge alarms were found inoperable. Prove proper operation to the satisfaction of an attending USCG Marine Inspector. 46 CFR 182.530.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2024
Resolution: Engine room high bilge water float switch was replaced, new ring bell for audio alarm was installed, tested all 03 high water bilge alarms for both audio and visual and all were found operating properly.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 September 2024 Resolved
A vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables. Vessel must provide up-to-date U.S. Coast Pilot [name withheld] Lists, all dated YR2023; and current tables. 46 CFR 184.420.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 12 September 2024
Resolution: Updated publications were provided for the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2024 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Pre-engineered fire suppression systems was serviced SEPT2024 and provided did not provided servicing certificate with a service report of test or inspection. 46 CFR 176.810.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 25 September 2024
Resolution: Master provided satisfactory evidence of the required servicing report to the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2024 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Two "U" type bolts securing both throttle cables (starboard side) underneath the controls at the operating station were found corroded and in need for replacement. 46 CFR 176.840.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 25 September 2024
Resolution: "U" type bolts securing both throttle cables underneath the controls at the operating station were replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2024 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Four dead-end electrical wires were found underneath the operating station. Properly reconnect the equipment it was in connection with, remove, or secure them inside of a electrical junction box. 46 CFR 176.840.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 25 September 2024
Resolution: Four dead-end electrical wires removed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 September 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Top lifefloat retroreflective material was found wasted. 46 CFR 176.830.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 25 September 2024
Resolution: LF retro-tape replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 September 2024 Resolved
A submersible electric bilge pump shall be permanently mounted. Engine room submersible bilge pump was found to be glued instead of permanently secured to the bottom of the hull. 46 CFR 182.520 (e)(3).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 12 September 2024
Resolution: Pump was secured permanently to the hull.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 11 September 2024 Resolved
Each life float and buoyant apparatus must be stowed as required under this section: (b) The float-free link required by § 180.130(a)(1) with a proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Port side lifefloat weak-link needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 25 September 2024
Resolution: Weak-link replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 September 2024 Resolved
A hatch exposed to the weather must be watertight. Clean all deck hatches rubber gaskets, found with debris and oily substance. 46 CFR 179.330.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 12 September 2024
Resolution: Hatches were cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2023 Resolved
Each life ring buoy on a vessel must be approved in accordance with section 160.050. Life ring buoy inner seal is loose and not serviceable. 46 CFR 180.70(b)(2) 46 CFR 160.050
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 2 October 2023
Resolution: New life buoy purchased to renew.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 September 2023 Resolved
Buoyant apparatus with plastic foam buoyancy external protective covering must be: (1) Fibrous-glass-reinforced plastic, constructed of a polyester resin listed on the current Qualified Products List for MIL–P–21607E(SH) or accepted by the Commandant (CG–ENG–4) as meeting MIL-P-21607; (2) Elastomeric vinyl accepted by the Commandant (CG–ENG–4) as meeting § 160.055–3(j) of this chapter; (3) Any other material accepted by the Commandant (CG–ENG–4) as providing equivalent protection for the body of the apparatus. 46 CFR 180.200(a)(2) 46 CFR 160.027-2(a) 46 CFR 160.010-5(c) 705-Prior to completion of next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2023
Resolved 23 December 2023
Resolution: Life floats were painted with approved FLEXABAR bouy paint.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 20 September 2023 Resolved
Operator must secure each Type III device in a manner which prevents discharge of sewage. Overboard discharge valve assembly is leaking (steady slow drip) sewage into the bilge. 46 CFR 184.704 33 CFR 159.7 (c)(2) 705c - Prior to pumping sewage
Action required: 705 - Other - as specified
Resolved 2 October 2023
Resolution: Sewage valve renewed. Pump out completed with no leaks noted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 September 2022 Resolved
On each container for life jackets, the number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers at least 2 inches high. The stowage containers for the adult and child life jackets must be marked in accordance with the regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 19 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 September 2022 Resolved
The color of the bouyant apparatus must be primarily vivid reddish orange. The life floats were discolored and had minor cracks around the corners.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 23 December 2022
Resolution: Vessel owner sent images of newly restored and painted life floats as per instruction from OCMI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 July 2020 Resolved
Contact cognizant OCMI to conduct a New to Zone Inspection prior to the carriage of passengers. Vsl was constructed in Sector New Orleans OCMI zone. Vsl will depart Sector New Orleans OCMI zone and will be home ported in Sector San [name withheld] zone, where the VSL will coordinate and conduct the New To Zone COI inspection. 46 CFR 176.840 701 C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2020
Resolution: Conducted New To Zone Inspection. All satisifactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.