MAURY USCG vessel records
← All vessels

ICON OF THE SEAS

ICON OF THE SEAS is a 2023 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2023, most recently in June 2026, along with 6 deficiencies and 1 operational control.

Records from 2023 to 2026. Most recent: inspection, 13 June 2026.

Built
2023
Last inspected
13 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9829930
1602780
Flag
BAHAMAS, THE
Maury page id
psix-1602780

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2023–2026)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it21513 - Dead Weight, Ton
114291 - Displacement, Ton
248663 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 13

13 June 2026 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8402918
13 December 2025 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8276082
19 September 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8237677
28 June 2025 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8168050
28 December 2024 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8051150
25 September 2024 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8009193
29 June 2024 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7943693
19 January 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7851507
14 January 2024 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7849198
5 January 2024 PSC A · COC-CVE Initial
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7843910
4 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7845180
11 August 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7765697
1 May 2023 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7689430

Deficiency record · 6

14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 13 December 2025 Resolved
To enable pipes of reception facilities to be connected with the ship's discharge pipeline for residues from machinery bilges and from oil residue (sludge) tanks, both lines shall be fitted with a standard discharge connection. PSCOs observed sludge manifolds did not meet the six bolt requirement of MARPOL annex I. MARPOL 2017 Annex I/13 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2026
Resolved 13 January 2026
Resolution: Received class report attesting to the installation of standard discharge connections.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 December 2025 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purposes of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCOs observed combustible materials stowed in IT locker on D12MVZ6 and in A/C space on D6MVZ2. 74 SOLAS 20 II-2/9.2.2.3.2.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 December 2025
Resolved 13 December 2025
Resolution: Combustibles were rapidly removed form the aformentioned spaces and properly disposed of during the exam.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 25 September 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on borad. PSCO's were informed diesel generator #4 experienced engine breakdown and no root cause analysis was provided. 74 SOLAS (20) I / Reg 11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2024
Resolved 19 December 2025
Resolution: See documents from class and technical reports.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 June 2024 Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and lifraft embarkation deck. For this purpose, the following functional requirements shall be met: additional aids for escape shall be provided as necessary to ensure accessibility, clear marking, and adequate design for emergency situations. Emergency escape signage was not adequate in the steering gear room, center azipod space, as well as in the deck 6, comedy club room where one of the two means of escape was obstructed. 74SOLAS 20 CH. II-2 / REG 13.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 June 2024
Resolution: Staff installed signage in areas to ensure vision of emergency exit signage was visible
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 June 2024 Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. Stores were blocking escape route on I-95 aft. 74 SOLAS 20 CH. II-2 / REG 13.1.2
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 29 June 2024
Resolution: Staff cleared the pathway before departure
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 January 2024 Resolved
Electrical installations shall be such that: safety of passengers, crew and ship from electrical hazards will be ensured. The electrical wiring in the aquadome jewelery store, and main theater was out and disconnected. 74 SOLAS (20) II-1 / 40.1.3 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2024
Resolved 8 January 2024
Resolution: Sector Miami received documentation from class attesting to the required repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.