DISCOVERY PRINCESS

DISCOVERY PRINCESS is a 2022 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 2021, most recently in April 2026, along with 17 deficiencies and 1 operational control.

Records from 2021 to 2026. Most recent: inspection, 26 April 2026.

Built
2022
Last inspected
26 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9837468
1602781
Flag
BERMUDA
Maury page id
psix-1602781

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (2021–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it145281 - Convention (Subpart B), Gross Ton
11992 - Dead Weight, Ton
71587 - Displacement, Ton
122695 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 44

26 April 2026 PSC A · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8354962
2 September 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8225641
8 March 2025 COC-CVE Annual · PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8090391
9 September 2024 PSC B · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7999679
14 May 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7929772
25 April 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7917960
23 April 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7900007
15 April 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7895224
28 March 2024 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7887148
14 March 2024 MARPOL Annex VI Survey · Administrative Inspection · COC-CVE Annual · PSC A
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7878960
2 March 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7879814
15 February 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7872343
27 January 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7874048
6 January 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7875846
26 October 2023 COC-CVE Quarterly · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7814511
12 July 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7833594
28 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7805662
28 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7805665
7 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7760406
7 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7785719
24 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7745282
24 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7745774
10 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7742051
10 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7742057
12 April 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667429
16 March 2023 COC-CVE Annual
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7652483
13 March 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7650158
10 March 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7648984
13 February 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7636134
30 December 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7614666
21 November 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7598162
12 October 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7576270
21 September 2022 PSC B · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7562367
23 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542022
20 August 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7542531
8 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7528570
29 July 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7519791
23 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7485452
21 June 2022 In-Service Inspection · Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7483234
21 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7483369
15 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7478759
13 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476554
21 March 2022 PSC A · ISPS Exam · Ballast Water Examination · COC-CVE Initial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7406118
24 September 2021 COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 7319437

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 September 2025 Resolved
Fire doors in main vertical zones bulkheads, galley boundaries and stairway enclisures, double leaf doors equipped with a latch necessary for their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. PSCO observed when released, on the sides of the double leaf fire screen door 6.6.01 did not secure properly. 74 SOLAS 20 II-2/9.1.1.5.12
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 September 2025
Resolution: Rectified.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 September 2024 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. During the ships drill several stairway guides were asked to show the where the nearest fire extinguisher was, several did not know and when they were found the majority of them were unfamiliar with how to deploy the fire extinguisher. 74 SOLAS 20 II-2/15.2.2.1 , 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2024
Resolution: Crew training to 21 personnel was provided prior to inspectors departing vessel.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 September 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, double-leaf doors equipped with a latch necessary for their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. When released, one of the sides of the double leaf fire screen door 05.6.13 did not secure properly.74 SOLAS 20 II-2/9.4.1.1.5.12, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 September 2024
Resolution: Fire door mechanical components were adjusted. Door was tested and was able to latch close as designed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 March 2024 Resolved
The construction of doors and door frames in “A” class division, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. STBD side EGEN door did not fully close. 07105 74SOLAS (20) II-2/9.4.1.2 16ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 March 2024
Resolution: Vessel rectified deficiency prior to inspection team departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 March 2024 Resolved
Doors and door frames in “B” class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of divisions. Fire door 9201 did not fully close. 07105 74 SOLAS (20) II-2/9.4.1.2.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2024
Resolved 28 March 2024
Resolution: Vessel provided class report attesting to rectification of faulty door.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 March 2024 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Electrical panel in Princess Theater control center is taped in a partially open position. 09209 74 SOLAS (20) II-1/40.1.3 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2024
Resolved 28 March 2024
Resolution: Vessel provided class report attesting to rectification of electrical panel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 March 2024 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. Teen Center (CAT 8 space) on deck 17 has twist locks and twist handles on both escape routes. 07120 74 SOLAS (20) II-2/13.3.2.6.2 50ac
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2024
Resolved 15 April 2024
Resolution: Rectified to satisfaction of vessels flag administration.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 March 2024 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. Broadcasting center (9505) has permanent accommodation changing space categorization. 07101 74 SOLAS (20) II-2/9.2.2.3.1 50ac
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2024
Resolved 23 April 2024
Resolution: Vessels flag state has attested to proper space categorization for broadcasting center.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 March 2024 Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. Escape route located within galley space in way of cold room 17401 is partially obstructed. Partially blocked egress behind Princess theater. 07120 74 SOLAS (20) II-2/13.1.2 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 15 March 2024
Resolution: Vessel cleared obstructions in both Egress routes prior to exam team departing vessel.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 March 2024 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. 02 stairway guides on deck 8 fwd stairway were not familiar with ships emergency procedures allowing passengers to return to estate rooms during emergency. 02 passenger muster accountability personnel were unfamiliar of procedures if check-in tablet did not function. Vessel provided immediate crew training to members. 04110 74SOLAS (20) III/19.2.1 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 15 March 2024
Resolution: Crew members were provided immediate training prior to exam crew departing vessel.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 March 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more then 40 s and no less than 10 s from the beginning of their movement. Fire door FSD 05.7.02 closed in less then 10 seconds. 07105 74 SOLAS (20) II-2/9.4.1.1.5.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 March 2024
Resolution: Vessels crew rectified door closure time prior to exam team departing vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 13 March 2023 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATION TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO WAS INFORMED OF INOPERABLE PORT ANCHOR DUE TO TRANVERSE PIN OUT OF POSITION AND LOST HEAD PIN.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 12 April 2023
Resolution: Class cleared Def.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 21 September 2022 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. The Company should establish procedures, plans, and instructions for key shipboard operations concerning the safety of the personnel, ship and protection of the environment, Marine Inspector observed multiple unattended housekeeping carts on several decks, demonstrating lack of training or procedures for maintaining adequate means of egress.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 18 October 2022
Resolution: Received notification of def clearance from Bermuda
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 September 2022 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Marine inspector observed foam nozzle utilized for fire drill team leaking water and unale to fully close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 4 October 2022
Resolution: Received statement from fire servicing technician.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 September 2022 Resolved
In addition to emergency lighting required...The markings must enable passengers to identify the routes of escape and readily identify the escape exits. Marine Inspector observed insufficient signage for escape from the casino on deck 6 and from women's changing room vestibule in the spa on deck 5.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 18 October 2022
Resolution: Received letter of acceptance regarding exit signage
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 21 September 2022 Resolved
In addition to emergency lighting...The means of escape including stairways and exits shall be marked by lighting or photo luminescent strip indicators not more than 300mm above the deck. Marine Inspector observed furniture, storage equipment, and decorations blocking low level lighting at deck 5 spa, deck 8 corridor, and deck 4 main corridor.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 September 2022
Resolved 21 September 2022
Resolution: The furniture, storage equipment, and decorations on the specified decks were all relocated out of the way of the low level lighting.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 September 2022 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with an equivalent unit. Marine Inspector observed a pallet of construction materials blocking acces to fire extinguisher on deck 4.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 September 2022
Resolved 21 September 2022
Resolution: The pallet of construction materials on deck 4 was relocated as to unblock access to the fire extinguisher and allow it to be readily available for immediate use.