MAURY USCG vessel records
← All vessels

VIKING MISSISSIPPI

VIKING MISSISSIPPI is a 2022 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2020, most recently in July 2026, along with 9 deficiencies, 1 operational control and 2 casualty investigations between 2023 and 2025.

Records from 2020 to 2026. Most recent: inspection, 17 July 2026.

Built
2022
Last inspected
17 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 July 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN2333
1603153
Flag
UNITED STATES
Maury page id
psix-1603153

Documentation record

Registered dimensions (L × B × D)452.6 ft × 76.1 ft × 14.1 ft
Registered tonnagegross 7,116 / net 6,460
ITC dimensions (L × B × D)452.6 ft × 76.1 ft × 14.1 ft
ITC tonnagegross 12,621 / net 3,786
BuilderLA SHIP LLC · HOUMA, LA, UNITED STATES · built 2022
Hull materialSteel
PropulsionDiesel Electric
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12621 - Convention (Subpart B), Gross Ton
7116 - Regulatory (Subpart C or D), Gross Ton
3786 - Convention (Subpart B), Net Ton
6460 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 34

17 July 2026 Re-Inspection · MTSA Verification · Vessel Attendance
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8440712
15 April 2026 Re-Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8349627
5 February 2026 MTSA Verification · Vessel Attendance · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8304795
16 December 2025 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8284310
3 December 2025 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8276933
11 November 2025 Security Breach · Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8267054
28 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8259766
8 October 2025 Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8249670
20 September 2025 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8237753
20 September 2025 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8238169
20 September 2025 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8271069
22 August 2025 Damage Survey
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8227980
31 July 2025 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8210076
15 July 2025 MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8186491
29 April 2025 MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8123244
5 February 2025 MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8074953
30 September 2024 Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8011475
22 July 2024 Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7964223
8 July 2024 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7954343
3 April 2024 Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7889531
5 January 2024 Load Line/Change of Employment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7836185
4 October 2023 MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7803508
3 October 2023 Construction Oversight · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7803266
12 August 2023 Administrative Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7766245
2 August 2023 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7786295
21 July 2023 Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7748419
3 May 2023 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7680073
1 May 2023 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7678535
25 January 2023 Exemption · MTSA Verification · Damage Survey · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7632999
24 January 2023 Load Line/Change of Employment
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7626556
3 December 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7610200
17 October 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7578672
17 August 2022 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7536519
6 August 2020 Initial Certification · Administrative Inspection · Construction Oversight · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7025916

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2025 Resolved
Doors in Class "A" bulkheads shall have a latch with a minimum throw of 3/4 inch which can be operated from either side of the door. The Class A door leading to the engine room had a door handle missing leading to an opening in the door. Replace door or handle too meet class A standards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2025
Resolved 16 December 2025
Resolution: Received photos attesting to the installation of a latch and handle for door used to enter the engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2025 Resolved
Electric installations on vessels must ensure:(1) Maintenance of services necessary for safety under normal and emergency conditions. The vessel suffered a complete loss of 07 generators, causing a total blackout and loss of propulsion. Diagnose the cause of the failure and complete all necessary repairs prior to moving from the vessel's current location.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 September 2025
Resolved 21 September 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 September 2025 Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 70.35 of this subchapter, will be considered satisfactory evidence of the structural efficiency of the vessel. Vessel grounded on the bow as a result of a loss of propulsion. Verify the structural integrity of the hull in the vicinity of the grounding location prior to movement from the vessel's current location.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 20 September 2025
Resolved 21 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 May 2025 Resolved
Fire boundary doors shall be of the self-closing type capable of closing against a 3 1/2 degree list. The Class A-0 fire rated door in the main laundry room did not have a door closure attached. Install closure and test to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2025
Resolved 5 May 2025
Resolution: Door closure installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 February 2025 Resolved
Bulkheads or decks of the “A” Class shall be constructed that, if subjected to the standard fire test, they would be capable of preventing the passage of smoke and flame for 1 hour. Doors in bulkheads required to be Class A-60, A-30, or A-15 shall be of hollow steel or equivalent metal construction solidly filled with approved structural insulation capable of meeting the requirements for a Class A-15 bulkhead. 5 doors would not automatically close once released from holdback. Repair and test.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2025
Resolved 6 February 2025
Resolution: All doors adjusted and operating properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 February 2024 Resolved
Various means of escape and electrical distribution rooms were significantly impeded by hotel equipment, stores & shelving. Areas are to be kept clear as to not block/impede these areas.
Action required: 10 - Deficiency Rectified
Due 14 February 2024
Resolved 15 February 2024
Resolution: Areas cleared prior to issuance of COI.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 May 2023 Resolved
All doors, except those that are kept normally closed, shall be of a type which are capable of release from the control station and from a position at the door. The release mechanism shall be designed so that the door will automatically close in the event of disruption to the control system. Main passage fire door on Deck 3 was not fully closing when activated. Repair door to ensure full closure.
Action required: 10 - Deficiency Rectified
Resolved 1 May 2023
Resolution: Door was adjusted during inspection and fully closes when release is activated.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 May 2023 Resolved
Doors in "B" Class bulkheads shall meet the requirements of 46 CFR 72.05-25(c). A door in a Class "B" Fire Boundary on the periphery of the galley had been removed for convenience. Removal of door was unauthorized. Re-fit Class "B" door into boundary prior to getting underway with passengers.
Action required: 10 - Deficiency Rectified
Resolved 1 May 2023
Resolution: Class B door has been replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 December 2022 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. On December 3, 2022 while moored at Mardi Gras World in New Orleans, LA the gangway fell from the 02 deck which resulted in injuring passengers. Provide procedures and training for vessel's crew on proper placement and rigging of the vessel's gangway to the satisfaction of attending Marine Inspector from Sector New Orleans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2023
Resolved 30 March 2023

Casualty record · 2

2 August 2023Routine · role: Involved in a Marine Casualty · activity 7786295
20 September 2025Routine · role: Involved in a Marine Casualty · activity 8271069
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.