Records from 2020 to 2026. Most recent: inspection, 25 February 2026.
Inspection history · 14
25 February 2026
Administrative Inspection · PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8316674
6 February 2025
PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8073873
6 February 2024
COC-GAS Renew · PSC B · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7861598
8 March 2023
COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7644324
7 September 2022
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7553353
1 March 2022
PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7401262
12 June 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7223012
12 June 2021
ISPS Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7223043
12 June 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7225012
11 June 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7223143
29 March 2021
COC-GAS Annual · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7165095
30 May 2020
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6964042
20 February 2020
PSC A · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6905006
20 February 2020
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7089466
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 20 February 2020
Resolved
On ships carrying flammable and/or toxic products, a water spray system, for cooling fire prevention and crew protection shall be installed to cover exposed lifeboats, liferafts, and muster stations facing the cargo area, regardless of distance to cargo area.
Forward most life raft is not covered by deck water spray system; the deck water spray system is not piped/constructed for coverage over forward most life raft.
74SOLAS (14) VII/13.1
ref. 2016 IGC Code 11.3.1.7
50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 30 May 2020
Resolution: Received class report rectifying the deficiency.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 20 February 2020
Resolved
Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products.
PSCO observed incorrect electrical cable termination/blank cap on 02 lighting fixtures (one in SOPEP locker, one in aft most deck store). These fixtures do not have certified safe blank caps and lie within the gas dangerous/hazardous area.
74 SOLAS (14) VII/13.1
ref. 2016 IGC Code 10.2.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 9 March 2020