MAURY USCG vessel records Sign in
← All vessels

ESCAPADE

ESCAPADE is a 1978 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1993, most recently in May 2016, along with 232 deficiencies — 1 with no resolution recorded —, 1 operational control and 4 casualty investigations between 2006 and 2010.

Records from 1993 to 2016. Most recent: inspection, 9 May 2016.

Built
1978
Last inspected
9 May 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7802689 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB8251
160339
Flag
UNITED STATES
366955610, 367456070, 367543420 (licence lapsed)
Maury page id
psix-160339

Inspections, by type

…with no type recorded32
…past their stated due date1
Years with a record 20 calendar years (1993–2016)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it1320 - Convention (Subpart B), Gross Ton
847 - Displacement, Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
396 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDG5110MMSI 367543420 · expired · compulsorily equipped · granted 24 August 2012, cancelled 29 October 2022
WDF4808MMSI 367456070 · expired · compulsorily equipped · granted 8 June 2010, cancelled 8 August 2020
WDB8251MMSI 366955610 · expired · compulsorily equipped · granted 11 June 2004, cancelled 16 August 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCA7945MMSI not assigned · expired · compulsorily equipped · granted 13 December 1994, cancelled 12 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GOLDEN RETRIEVER Commercial Fishing Vessel · MISLE 152179 · 29 April 2007 · activity 2919042

Inspection history · 94

9 May 2016 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5874585
7 December 2015 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5780040
25 August 2015 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5226144
23 June 2014 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4914346
22 September 2011 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4151845
14 January 2011 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3929976
13 September 2010 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3848803
9 February 2010 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3680978
4 December 2009 Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3659630
17 September 2008 COI Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3330215
6 December 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3111469
26 November 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3104435
29 April 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2919042
26 January 2007 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2862120
9 January 2007 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2852846
2 October 2006 Administrative Inspection · MTSA Verification
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2792010
1 August 2006 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2732455
24 July 2006 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2723521
18 April 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2627495
30 March 2006 In-Service Inspection · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2634622
8 December 2005 MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2548148
15 November 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2535056
18 January 2005 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2276371
11 August 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2162855
10 November 2003 Inclining Experiment · Hull Examination · Internal Structural Exam · MTSA Verification · COI Inspection · Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1946945
14 July 2000 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1369764
17 May 2000 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1399389
27 January 2000 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1404877
28 October 1999 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1384283
7 September 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 42606
9 August 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1436281
16 July 1999 COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1338625
20 April 1999 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1360927
25 January 1999 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1455662
20 October 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1453524
26 August 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 798504
17 July 1998 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1468870
15 June 1998 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1472663
26 January 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116381
27 August 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1123483
22 August 1997 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1121318
7 July 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1371893
30 June 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1112740
23 June 1997 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 776628
18 March 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 86260
18 March 1997 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1100583
10 March 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1374903
2 December 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1383382
20 August 1996 Deficiency Check · Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1446393
5 August 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1357696
3 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 166819
6 July 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 166525
19 May 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 180474
10 May 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 25987
3 March 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 65171
13 February 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1385712
28 November 1995 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1424170
5 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 24565
31 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 226186
15 August 1995 COI Inspection · Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1363342
18 July 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877831
3 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 77478
30 May 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874276
18 May 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 90415
4 April 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839751
28 February 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 867955
29 November 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1144077
27 November 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 53471
10 November 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 865301
4 October 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 141066
3 October 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 34755
16 September 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1178443
10 September 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 46625
6 September 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1178444
15 August 1994 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1024990
27 June 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1332925
28 April 1994 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1458152
16 March 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1165566
1 February 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 856409
29 January 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 63916
25 January 1994 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1162018
20 January 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 216158
28 December 1993 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1161113
21 December 1993 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1444778
7 December 1993 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1161596
30 November 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1159145
24 November 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 696106
16 November 1993 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1428283
1 November 1993 Damage Survey · Examination of Repairs
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1431277
29 October 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 11157
29 October 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 222410
29 October 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 226637
14 September 1993 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1148029
14 September 1993 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1471097

Deficiency record · 232

Operations/Management › Drills/Instruction › Not Conducted
Issued 7 December 2015 No resolution recorded
Prior to operating with passengers the vessel must undergo an in-service CG inspection to ensure all safety & security plans are properly activated & all equipemnt is ready for service. To include conducting drills to the satisfaction of attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2015 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 June 2014 Resolved
Install guard on #2 air compressor in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 June 2014 Resolved
Replace expired items in first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2014
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 June 2014 Resolved
Replace expired publications on bridge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2014
Resolution: New pubs were provided.
Lifesaving › Lifefloat › Float Free
Issued 23 June 2014 Resolved
Store lifefloats in a float free arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2014
Lifesaving › Lifefloat › Serviceable
Issued 23 June 2014 Resolved
Repair or replace (6) lifefloats or take reduction in passenger count.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2014
Lifesaving › Lifefloat › Lifeline
Issued 23 June 2014 Resolved
Repair all parted lifelines for lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2014
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 23 June 2014 Resolved
Replace all lines from lifefloats to floating waterlights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 June 2014 Resolved
Repair wiring in both of the stacks on the third deck stern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2014
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 September 2011 Resolved
Renew the missing door latch in the galley fire door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2011
Resolved 7 November 2011
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 September 2011 Resolved
Place fire stop and seperate cables penetrating the fwd structural fire boundary on the STBD side main deck.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 December 2011
Resolved 24 August 2012
Resolution: Fire stop installed and cables separated at penetration in the fwd structural fire boundary on the STBD main deck.
Electrical › Electrical Distribution System (service) › Conductor
Issued 22 September 2011 Resolved
Separate 5 volt signal cables from main power cables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2011
Resolved 7 November 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 22 September 2011 Resolved
Renew missing grommets in Roxtec BHD penetration located on the STBD side of the engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2011
Resolved 7 November 2011
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 September 2011 Resolved
With the exception existing magnetic door hold backs. All holdback mechanisms on fire doors are to be removed.
Condition: Improper Installation
Due 30 December 2011
Resolved 7 November 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 22 September 2011 Resolved
Replace portable chemical fire extinguisher in the bracket located on the main deck aft the last BHD.
Condition: Improper Installation
Due 30 December 2011
Resolved 7 November 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 September 2011 Resolved
Repair the CO2 shut down on the bow thruster engine.
Due 30 December 2011
Resolved 22 November 2011
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 September 2011 Resolved
Ensure fire doors on the second deck are installed with appropriate closure delay device to ensure the proper door closes first.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2011
Resolved 25 August 2012
Resolution: fire doors on the second deck are installed with appropriate closure delay device ensuring the proper door closes first.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 22 September 2011 Resolved
Ensure SFP is installed in the stairwell in accordance with approved SFP plan.
Condition: Improper Installation
Due 30 December 2011
Resolved 24 August 2012
Resolution: Verified SFP is installed in the stairwell in accordance with approved SFP plan.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 September 2011 Resolved
Perform all drills prior to carraige of passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 November 2012
Resolved 24 August 2012
Resolution: Witnessed satisfactory fire, abandon ship, and man overboard drills.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 22 September 2011 Resolved
Hydrostaticaly test the air receivers located in the engineroom. And pressure test the relief valves for these receivers
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 January 2012
Resolved 17 August 2012
Resolution: Air receivers externally inspected during exam and internally inspected in 2010 as per the COI. Hydrostatic test not required.
Engineering › Bilge Water Management System › Valve
Issued 22 September 2011 Resolved
Label bilge an ballast system valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2012
Resolved 1 October 2012
Resolution: Verified proper labelling of bilge and ballast manifold system.
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 22 September 2011 Resolved
Label 110 volt circuit breaker pannels that ar attached to 220 volt switch boards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2012
Resolved 26 September 2012
Resolution: 110 volt circuit breaker panels properly labelled.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 September 2011 Resolved
Ensure all circuit breakers are properly labeld through out the vessel.
Condition: Improper/Lack of Maintenance
Due 22 January 2012
Resolved 26 September 2012
Resolution: All circuit breakers and distribution panels properly labelled throughout the vessel.
Fire Fighting › Ventilation Systems › Ducts
Issued 22 September 2011 Resolved
Repair/Renew CO2 activated servo on ventilation damper in bow thruster room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2012
Resolved 24 August 2012
Resolution: CO2 activated servo on ventilation damper in bow thruster room renewed in kind.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 22 September 2011 Resolved
Reattach water light to life floats in way of stbd running light.
Action required: 705 - Other - as specified
Due 22 January 2012
Resolved 24 August 2012
Resolution: Verified water light was reattached to lifefloats in way of stbd running light.
Lifesaving › Lifefloat › Float Free
Issued 22 September 2011 Resolved
Ensure life floats are float free prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 January 2012
Resolved 24 August 2012
Resolution: Lifefloats have been made float free.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 22 September 2011 Resolved
Place locking mechanism on all bolted connections in both switch boards e.g. lock nuts
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 January 2012
Resolved 24 August 2012
Resolution: Locking mechanisms placed on all bolted connecitons in both swith boards.
Construction/Loadline › Hull › Bottom Plating
Issued 14 January 2011 Resolved
Replace wasted stbd keel cooler deck plating located in void forward of the main engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2011
Resolution: Verified satisfactory replacement of wasted section of stbd keel cooler deck plating. Witnessed satisfactory NDT air test at 1.5 PSI.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 January 2011 Resolved
Replace worn/holed areas of the stbd ballast wing tank in bulkheads 49 and 58.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2011
Resolution: Verified satisfactory replacement of wasted section of stbd ballast wing tank in bulkheads 49 and 58. Witnessed satisfactory NDT air test at 1.5 PSI.
Construction/Loadline › Hull › Hull Plating
Issued 14 January 2011 Resolved
Replace worn hull plating on port side near amidships between WTB 49 and 58. Hole located in bottom plating outboard of the engine room to bow thruster room tunnel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2011
Resolution: Verified satisfactory replacement of worn hull plating on port side near amidships b/w WTB 49 and 58. Witnessed satisfactory NDT air test at 1.5 PSI.
Construction/Loadline › Structures › Scuttle
Issued 14 January 2011 Resolved
Replace/repair water tight hatches on the main deck leading to lazarette, port ballast tank and stbd ballast tank. None are currently water tight due to wastage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2011
Resolution: The lazarette water tight hatch gasket was replaced (temporary repair - hatch needs replaced) and the port and stbd ballast tank water tight hatches made approved temporary repairs to the hatch covers by welding steel plate over the existing man holes.
Engineering › Bilge Water Management System › Pump
Issued 14 January 2011 Resolved
Prove proper operation of lazerette bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2011
Resolution: Witnessed proper operation of bilge alarm.
Fire Fighting › Ventilation Systems › Ducts
Issued 9 February 2010 Resolved
Draft damper is designed with fusable link and Pull wire. Current connection of link to the weighted arm of the fire damper is tied with a plastic wire tie. Pull wire and link to be re configured to original installation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2010
Resolved 1 July 2010
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 9 February 2010 Resolved
Ensure all internal combustion engines in the engineroom that have air intakes in the compartment shut down upon release of fire supression medium.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2010
Resolved 1 July 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 December 2009 Resolved
All drills, Logs and associated records to be accepted by cognizant OCMI prior to sailing with passengers.
Action required: 705 - Other - as specified
Due 4 December 2010
Resolved 9 February 2010
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 4 December 2009 Resolved
Fire detection system to be tested to the satisfaction of the cognizant OCMI prior to operating with passengers on board.
Action required: 705 - Other - as specified
Due 4 December 2010
Resolved 1 July 2010
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 4 December 2009 Resolved
Install structural fire protection on overhead in way of the number 1 SSG prior to operation with passengers on board.
Action required: 705 - Other - as specified
Due 9 February 2010
Resolved 9 February 2010
Documentation › Certificates/Documents › FCC SSL
Issued 4 December 2009 Resolved
Provide and post a current FCC SSL and a Communications Act Safety Certificate prior to operation with passengers onboard.
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 9 February 2010
Electrical › Electrical Distribution System (service) › Switchboard
Issued 4 December 2009 Resolved
Make internals of switchboard available for inspection by a marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 1 July 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 November 2008 Resolved
All logs, drills, security, operations, manning, training and licenses to be accepted by the cognisant OCMI prior to carraige of passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2009
Resolved 4 December 2009
Resolution: Re-issued due to vessle in layup status.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 November 2008 Resolved
Stencil Port engine room escape scuttle on bulkhead on main deck with 2 ' letters "EMERGENCY EXIT KEEP CLEAR"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2008
Resolved 15 December 2008
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 20 November 2008 Resolved
Ensure self closing engineroom door closes when engineroom ventilation is operational.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 15 December 2008
Lifesaving › Launching Appliances › Falls
Issued 20 November 2008 Resolved
Resize cables for rescue boat winch to fit throat radius of sheeves and handle weight of boat.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2008
Resolved 15 December 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 20 November 2008 Resolved
Provide UL Marine light fixtures in lieu of the existing Halogen Lamps on the exterior of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2008
Resolved 15 December 2008
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 26 September 2008 Resolved
Renew the improperly sized toilet seat in the main deck women's toilet with the appropriate sized split toilet seat.
Condition: Unknown
Due 31 October 2008
Resolved 2 October 2008
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 26 September 2008 Resolved
Ensure all fire doors located in structuraly fire protection boundaries have latches with a .75 " throw.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 15 December 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 September 2008 Resolved
Repair/renew emergency light in way of scullery door.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 2 October 2008
Documentation › Certificates/Documents › FCC SSL
Issued 17 September 2008 Resolved
Provide a current FCC Radio certificate.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2009
Resolved 15 December 2008
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 17 September 2008 Resolved
Renew or repair flushometers on urinals in the mens head on the second deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 2 October 2008
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 17 September 2008 Resolved
Repair or renew fire detection unit in scullery
Condition: Unknown
Due 31 October 2008
Resolved 1 July 2010
Electrical › Electric Generation Source (service) › Generator
Issued 17 September 2008 Resolved
Repair number 3 Ship Service Generator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 15 December 2009
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 17 September 2008 Resolved
Install structural Fire protection insulatioin on the engine room soft patch .
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 15 December 2008
Engineering › Pressure Vessel › Relief Valve
Issued 17 September 2008 Resolved
Renew pressure relief valves on the hot water heaters with relief valves rated at 100 PSI or less at 250 degrees F.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 15 December 2008
Construction/Loadline › Structures › Deck Plating
Issued 17 September 2008 Resolved
Replace section of deck plate immediately forward of engineroom ladder to protect personnel fromstepping into starboard shaft.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 15 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 September 2008 Resolved
Rewire engine room exhaust fan with marine cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 15 December 2008
Engineering › Fuel Oil Service System › Gauge
Issued 17 September 2008 Resolved
Provide quick acting self closing valves on the fuel tank sight glasses at next dry dock availability. Valves to be kept closed except when guaging tanks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2010
Resolved 1 July 2010
Fire Fighting › Firemans Outfit › Axe
Issued 9 January 2007 Resolved
Paint vessel's fireaxes red or re-stencil.
Condition: Improper Installation
Due 25 January 2007
Resolved 25 January 2007
Resolution: Fire axes painted red.
Engineering › Generator (propulsion-electric) › Indicator Circuitry
Issued 9 January 2007 Resolved
Repair or Replace #1GenSet KW gauge.
Condition: Improper/Lack of Maintenance
Due 25 January 2007
Resolved 4 April 2007
Resolution: Observed proper operation of #1 Kw gauge.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 9 January 2007 Resolved
Properly secure coffee machines on 2nd & 3rd deck bars to prevent movement.
Condition: Improper Installation
Due 25 January 2007
Resolved 25 January 2007
Resolution: Coffee machines secured with pieces of aluminum angle stock.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 January 2007 Resolved
Provide non-corrosive clips for all life buoy lights.
Condition: Improper Installation
Due 25 January 2007
Resolved 25 January 2007
Resolution: Clips installed on all waterlight lanyards.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 1 August 2006 Resolved
see narrative
Condition: Unknown
Due 10 September 2006
Resolved 24 August 2006
Resolution: Dive survey completed by Davidson Diving (Charleston).
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 March 2006 Resolved
CO2 tanks for bowthruster had not been hydrotested in 12 yrs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2006
Resolution: Tanks were tested and system was inspected and serviced.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 30 March 2006 Resolved
Ensure smoke detection sys. has adequate zones for each level of ship, and is operating properly.
Condition: Unknown
Due 15 May 2006
Resolved 8 January 2007
Resolution: Fire detection zones tested with satisfactory results.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 30 March 2006 Resolved
Provide a 2006 copy of local tides & currents
Condition: Unknown
Due 30 April 2006
Resolved 27 April 2006
Resolution: Copies of tides and currents onboard.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 30 March 2006 Resolved
Vessel shall remain in its current arrangement until plans are submitted and approved by the USCG MSC.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 13 June 2006
Resolution: provided new approved arrangement plan.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 30 March 2006 Resolved
Provide a valid copy of EPIRB registration.
Condition: Improper/Lack of Maintenance
Due 15 May 2006
Resolved 13 June 2006
Resolution: provided new registration.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 30 March 2006 Resolved
Ensure all draft marks are permanently marked at each end per USCG stability letter dated July 8,2004 AT NEXT VESSEL DRYDOCK.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 June 2006
Resolution: repaired original markings.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 30 March 2006 Resolved
Provide a copy of an approved certificate from SC DHEC before food service to passengers.
Condition: Unknown
Due 30 April 2006
Resolved 27 April 2006
Resolution: Certificate from SC DHEC provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 March 2006 Resolved
Provide proper battery boxes for all batteries in engine room
Condition: Unknown
Due 30 April 2006
Resolved 27 April 2006
Resolution: Battery boxes provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 March 2006 Resolved
Provide shatter guards for all lighting fixtures.
Condition: Improper Installation
Due 30 April 2006
Resolved 27 April 2006
Resolution: Shatter guards provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 March 2006 Resolved
Provide guard for emergency generator crackshaft balancer/rotating mass.
Condition: Improper/Lack of Maintenance
Due 30 April 2006
Resolved 27 April 2006
Resolution: Guard provided and installed
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 March 2006 Resolved
Properly affix charger wires to batteries behind emergency generator.
Condition: Improper/Lack of Maintenance
Due 14 April 2006
Resolved 14 April 2006
Resolution: Wiring properly connected.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 30 March 2006 Resolved
Prove proper operation of stbd MDE low lube oil level alarms.
Condition: Improper/Lack of Maintenance
Due 15 May 2006
Resolved 13 June 2006
Resolution: properly repaired.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 March 2006 Resolved
Prove proper operation of installed OWS.
Condition: Improper/Lack of Maintenance
Due 15 May 2006
Resolved 13 June 2006
Resolution: Removed OWS
Fire Fighting › Fire Main › Valves
Issued 30 March 2006 Resolved
Repair of replace fire main valve above main firepump
Condition: Improper/Lack of Maintenance
Due 15 May 2006
Resolved 13 June 2006
Resolution: fully repaired valve to prevent leakage.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 30 March 2006 Resolved
Remove all oil from bilges and provide a management proposal for condition.
Condition: Unknown
Due 15 May 2006
Resolved 13 June 2006
Resolution: cleaned bilges.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 March 2006 Resolved
Properly install wiring on gauge cluster of emergency generator.
Condition: Improper/Lack of Maintenance
Due 14 April 2006
Resolved 14 April 2006
Resolution: Wiring properly installed
Lifesaving › Visual Distress Signals (General) › Expired
Issued 30 March 2006 Resolved
Provide proper number of valid flares for rescue boat.
Condition: Improper/Lack of Maintenance
Due 14 April 2006
Resolved 30 April 2006
Resolution: Flares on board.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 30 March 2006 Resolved
Provide valid updated fire response plan for stern location
Condition: Unknown
Due 14 April 2006
Resolved 14 April 2006
Resolution: FRP provided and stored in designated tube.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 30 March 2006 Resolved
Repair or remove autopilot system.
Condition: Improper/Lack of Maintenance
Due 30 April 2006
Resolved 27 April 2006
Resolution: Autopilot system was removed from vessel.
Communications › Alarms/Indicators › High Water Alarm
Issued 30 March 2006 Resolved
Securely affix high water alarm switches in all bilges.
Condition: Improper Installation
Due 14 April 2006
Resolved 14 April 2006
Resolution: indicator switches were affixed to bulkheads.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 March 2006 Resolved
repair and/or secure are loose wiring in lazarette
Condition: Improper Installation
Due 30 April 2006
Resolved 27 April 2006
Resolution: Loose ended wiring has been removed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 30 March 2006 Resolved
Replace all plastic trash cans w/ non-combustible recepticles
Condition: Improper Installation
Due 15 May 2006
Resolved 13 June 2006
Resolution: Provided all metal receptacles.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 30 March 2006 Resolved
Update hailing port on all of vessel's lifesaving gear.
Condition: Improper/Lack of Maintenance
Due 30 April 2006
Resolved 27 April 2006
Resolution: Lifesaving gear markings updated.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 March 2006 Resolved
Properly label all distribution panels.
Condition: Improper Installation
Due 30 April 2006
Resolved 27 April 2006
Resolution: all panels labeled to identify zone.
Electrical › Electric Generation Source (emergency) › Conductor
Issued 30 March 2006 Resolved
Clean all emergency battery terminals.
Condition: Improper/Lack of Maintenance
Due 30 April 2006
Resolved 27 April 2006
Resolution: terminals cleaned.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 30 March 2006 Resolved
Replace all deteriorated retro tape on BA's
Condition: Improper/Lack of Maintenance
Due 30 April 2006
Resolved 27 April 2006
Resolution: tape replace w/ new material
Lifesaving › Buoyant Apparatus › Painter
Issued 30 March 2006 Resolved
Remove all wire ties from buoyant apparatus painters
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2006
Resolution: wire ties removed
Electrical › Electric Generation Source (emergency) › Generator
Issued 30 March 2006 Resolved
#2 (emergency) generator is to remain in emergency stand-by status until it does not pose a threat to the environment.
Condition: Improper/Lack of Maintenance
Due 15 May 2006
Resolved 13 June 2006
Resolution: Tuned up gen. to prevent any discharge of oil.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 March 2006 Resolved
Provide lagging for exhaust piping to turbo on #2 generator.
Condition: Improper/Lack of Maintenance
Due 15 May 2006
Resolved 13 June 2006
Resolution: Installed new lagging.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 March 2006 Resolved
Provide a suitable safe passenger loading arrangement for the embarkation/debarkation of passengers.
Condition: Improper Installation
Due 4 April 2006
Resolved 4 April 2006
Resolution: Loading station modified and secured for safety.
Fire Fighting › Fire Hoses › Number
Issued 30 March 2006 Resolved
Provide 02 fire hoses to replace burst units.
Condition: Improper/Lack of Maintenance
Due 4 April 2006
Resolved 4 April 2006
Resolution: 02 new units provided.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 30 March 2006 Resolved
Provide updated emergency contact numbers and ensure that vessel operation is in agreement with the Little River Mass Rescue Operation (MRO) plan.
Condition: Placed in Improper Service
Due 30 April 2006
Resolved 27 April 2006
Resolution: Updated info provided and amended vessel operations.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 December 2005 Resolved
Contact Marine Inspections office when next installed fire protection sysytem tested.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 6 June 2006
Resolution: complete.
Lifesaving › Launching Appliances › Davit
Issued 15 December 2005 Resolved
Provide a method of rotating (swivel) the rescue boat during launch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2006
Resolved 7 February 2006
Fire Fighting › Firemans Outfit › Gloves
Issued 15 December 2005 Resolved
Provide second pair of gloves for firemans outfit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 January 2006
Resolved 7 February 2006
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 15 December 2005 Resolved
Install new pressure gauge for upper air reciever and demonstrate proper operation of relief valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2006
Resolved 7 February 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 21 December 2004 Resolved
VARIOUS EXIT LIGHTS THROUGHOUT VESSEL FOUND INOPERTIVE
Due 21 January 2005
Resolved 28 December 2004
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 December 2004 Resolved
UPDATE AND POST EMER ERGRESS PLACARD
Due 21 January 2005
Resolved 21 December 2004
Resolution: PLANS POSTED
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 21 December 2004 Resolved
SFP MISSING IN SPOTS ENGINE ROOM, OBOVE RED GEAR
Due 21 January 2005
Resolved 27 December 2004
Resolution: SFP REPLACED IN ALL SPOTS IN ENGINE ROOM
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 December 2004 Resolved
DECK RAIL CUT AWAY AROUND RESCUE BOAT
Due 21 January 2005
Resolved 21 December 2004
Communications › Audible Communications › SPD (Other)
Issued 21 December 2004 Resolved
VESSEL SOUND POWER PHONE ARE NOT WORKING PROPERLY
Due 21 January 2005
Resolved 15 December 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 December 2003 Resolved
VESSEL TO CONDUCT SATISFACTORY DRILL PRIOR TO CARRIAGE OF PASSENGER
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2004
Resolved 27 December 2004
Resolution: CONDUCTED DRILL 27 DEC 2004 ALL SAT
Construction/Loadline › Structures › Deck Plating
Issued 10 November 2003 Resolved
Various deck, frames, bulkheads, stiffners, shelves, hull plating wasted. ask for gauge reading and approved plans to insure vessel is in complance with modifacation
Action required: 705 - Other - as specified
Resolved 15 December 2004
Fire Fighting
Issued 16 July 1999 Resolved
Update fire control (safety) plan to indicatefire boundaries and bulkhead classes.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Accommodation/Occupational Safety
Issued 16 July 1999 Resolved
Bow thruster room air receiver missing name plate data. Furnish name plateand test air receiver.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Accommodation/Occupational Safety
Issued 16 July 1999 Resolved
Potable water pressure tanks missing relief valves. Provide proper relief valves for air tanks.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Fire Fighting
Issued 16 July 1999 Resolved
Door closer missing from engineroom/main deck lounge door. Provide door closer.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Construction/Loadline
Issued 16 July 1999 Resolved
COMPLETE CREDIT DRY DOCK EXAMINATION TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO ANY FURTHER PASSENGER CARRYING SERVICE.
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Documentation
Issued 16 July 1999 Resolved
Low velocity fog applicators of the bored passage type. Provide approved open head type nozzles for all of the required low velocity fog applicators.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Accommodation/Occupational Safety
Issued 16 July 1999 Resolved
Bow thruster room air receiver missing relief valve. Install and test relief valve.
Condition: Unknown
Due 4 October 1999
Resolved 4 October 1999
Lifesaving
Issued 20 October 1998 Resolved
PROVIDE ONE IMMERSION SUIT FOR EACH MEMBER OF THE RESCUE BOAT CREW.
Condition: Unknown
Due 27 October 1998
Resolved 5 November 1998
Lifesaving
Issued 20 October 1998 Resolved
CLEARLY MARK EXITS FROM MACHINERY SPACE.
Condition: Unknown
Due 27 October 1998
Resolved 5 November 1998
Lifesaving
Issued 20 October 1998 Resolved
OUTFIT RESCUE BOAT AS PER TABLE 199.175 IN 46CFR.
Condition: Unknown
Due 27 October 1998
Resolved 5 November 1998
Electrical
Issued 20 October 1998 Resolved
SECURE MOUNT OF LIGHT FIXTURE ABOVE STBD AFT WORK BENCH.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Engineering
Issued 20 October 1998 Resolved
INSTALL HANDLE FOR FUEL SHUT-OFF ON PORT MAIN ENGINE.
Condition: Unknown
Due 27 October 1998
Resolved 5 November 1998
Unknown
Issued 15 June 1998 Resolved
Company to show proof of established drug testing policy with local points of contact.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Accommodation/Occupational Safety
Issued 15 June 1998 Resolved
Remove combustible furnishings from the following areas: Casino deck-aft stbd bar top & wall cabinets, port cashier cabinets & counter top. Main deck- aft stbd bar top & wall cabinets. Sun deck- both wood bars & base cabinets. E-gen rm- wood table & wall cabinets. Prior to carrying passngrs.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Lifesaving
Issued 15 June 1998 Resolved
Remove all plastic trash cans and replace with metal or noncombustible equivalent.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Accommodation/Occupational Safety
Issued 15 June 1998 Resolved
Install A-15 door for dumb waiter in emergency generator room (currently A-O) IAW SFP plans.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Accommodation/Occupational Safety
Issued 15 June 1998 Resolved
Make permanent repairs to stbd engine room exhaust fan.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Lifesaving
Issued 15 June 1998 Resolved
Conducted emergency drills with complete crew prior to carrying passengers.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Documentation
Issued 15 June 1998 Resolved
Provide evidence of 10 certificated lifeboatman prior to carrying passengers.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Unknown
Issued 15 June 1998 Resolved
Contact local OCMI upon arrival new operating area and prior to carrying passengers.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Navigation
Issued 15 June 1998 Resolved
Provide current deviation table.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Electrical
Issued 15 June 1998 Resolved
Remove all extension cord wiring in machy space.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Electrical
Issued 23 June 1997 Resolved
REPAIR EMERGENCY LIGHTING IN AFTER STEERING SPACE.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Electrical
Issued 23 June 1997 Resolved
SECURE LOOSE WIRING IN WAY OF STBD SIDE AFT ENGINE ROOM.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Electrical
Issued 23 June 1997 Resolved
PROVIDE PROPER BATTERY BOX FOR BATTERIES IN WAY OF #3 SHIP SERVICE GENERATOR.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Accommodation/Occupational Safety
Issued 23 June 1997 Resolved
CLEAR AND PROPERLY LIGHT EMERGENCY ESCAPES (PORT AND STARBOARD) FOR MAIN ENGINE ROOM.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Accommodation/Occupational Safety
Issued 23 June 1997 Resolved
CLEAR AREA IN WAY OF ACCESS TO HALON ACCUATION STATION.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Engineering
Issued 23 June 1997 Resolved
REPLACE PORT SHAFT PACKING BOLT.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Engineering
Issued 23 June 1997 Resolved
REPAIR RELIEF VALVE ON #2 AIR COMPRESSOR.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Electrical
Issued 18 March 1997 Resolved
PROVE PROPER OPERATION OF THE #2 GENERATOR AND THE GENERAL SERVICE PUMP.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Unknown
Issued 18 March 1997 Resolved
Prove proper operation of main engines, ship service generators, fire and bilge pumps and electrical system in the engine room (ie. switchboard).
Condition: Unknown
Due 19 March 1997
Resolved 20 May 1997
Documentation
Issued 18 March 1997 Resolved
PROVIDE A MARINE SURVEYORS REPORT ATTESTING TO THE CONDITION OF THE VESSEL.
Condition: Unknown
Due 7 April 1997
Resolved 20 May 1997
Engineering
Issued 18 March 1997 Resolved
PROVE PROPER OPERATION OF THE OILY-WATER SEPARATOR.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Lifesaving
Issued 2 December 1996 Resolved
Correct the muster list. No one is designated to be in charge of life raftnumber 9.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Engineering
Issued 2 December 1996 Resolved
Prove proper operation of the high temp jacketwater alarms for the port andstarboard main diesel engines.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Electrical
Issued 5 August 1996 Resolved
Test and replace fuel hoses for all ship service diesel generators as necessary prior to 19 August 1996.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Deck/Cargo
Issued 5 August 1996 Resolved
Replace as original the first quarter shot of anchor chain in way of the first shot. The smaller size chain now installed is being damaged by the wildcat. The smaller chain links ae being twisted & bent out of shape. The smaller links are also slipping through the wildcat.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Navigation
Issued 5 August 1996 Resolved
Repair packing in rudder stock and lip seal in hatch to steering space prior to 19 August 1996.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Engineering
Issued 5 August 1996 Resolved
Prove proper operation of all main engine and ship service generator engineinhibitors IAW manufacturer's specifications.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Lifesaving
Issued 5 August 1996 Resolved
Renew 406MHz EPIRB hydrostatic release.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Engineering
Issued 5 August 1996 Resolved
Empty containment box at bunker station prior to bunkering.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Fire Fighting
Issued 5 August 1996 Resolved
Properly lable co2 and galley fire suppression pull stations prior to 19 August 1996.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Engineering
Issued 5 August 1996 Resolved
Permanently post oil transfer procedures at bunker station prior to bunkering.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Electrical
Issued 13 February 1996 Resolved
PROVIDE SUITABLE BATTERY TRAY FOR EMERGENCY DGEN IN ACCORDANCE WITH 46CFR 111.15-5.
Condition: Unknown
Due 13 February 1996
Resolved 13 February 1996
Navigation
Issued 13 February 1996 Resolved
PROVIDE UPDATE COMPASS DEVIATION CARD.
Condition: Unknown
Due 13 February 1996
Resolved 13 February 1996
Electrical
Issued 13 February 1996 Resolved
PROVIDE SUITABLE F/O VALVE TO SHUTOFF THE FUEL OIL SUPPLY TO THE EMERGENCY DGEN IAW 46CFR56.50-75(A)(2).
Condition: Unknown
Due 13 February 1996
Resolved 13 February 1996
Lifesaving
Issued 28 November 1995 Resolved
In accordance with 46CFR 75.15-10, provide safety measures to protect the crew from injury or going over the side during launching LRAs' from the topdeck. Submit this proposal in writing; if the proposal is accepted it_x001C_ shall be added to the vessel's emergency and safety manual as an amendment.
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Lifesaving
Issued 28 November 1995 Resolved
Provide suitable light covers for the engine room work bench.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Lifesaving
Issued 28 November 1995 Resolved
Provide screens for vent duct on engine room port side.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Lifesaving
Issued 28 November 1995 Resolved
Provide suitable ladders for amidships embarkation areas, per 46CFR75.50.7_x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Lifesaving
Issued 28 November 1995 Resolved
Provide hot water heater relief valve discharge piping directed toward the deck.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Lifesaving
Issued 28 November 1995 Resolved
Provide reefer alarms in accordance with 46CFR 113.45.5.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Electrical
Issued 28 November 1995 Resolved
Repair electrical breakers in galley panel for deep fat fryer and left slowcook oven.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Lifesaving
Issued 28 November 1995 Resolved
Provide a suitable "E" light in way of port aft embarkation area, muster station.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Fire Fighting
Issued 28 November 1995 Resolved
Repair fire screen door-galley to main stair tower_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Construction/Loadline
Issued 15 August 1995 Resolved
SUBMIT WRITTEN PROPOSAL FOR REPAIRS TO WASTED PLATING IWO NO 4 P VOID LOCATED ADJACENT TO AFT BULKHEAD AND ANY OTHER AREAS SHOWING WASTAGE GREATER THAN 25% ORIGINAL THICKNESS FOR REVIEW BY [name withheld] PRIOR TO DEPARTURE.
Condition: Unknown
Due 15 August 1995
Resolved 18 August 1995
Construction/Loadline
Issued 15 August 1995 Resolved
SUBMIT GAUGINGS REPORT FOR BOTTOM HULL PLATING FOR EVERY 10 SQUARE FT FOR VOID TANK 4 P/S ALONG WITH ORIGINAL SCANTLINGS FOR REVIEW BY [name withheld] PRIOR TO DEPARTURE.
Condition: Unknown
Due 15 August 1995
Resolved 5 October 1995
Construction/Loadline
Issued 15 August 1995 Resolved
No later than 16 Feb 1996, the port and stbd number 4 voids are to be made available for examination by a Coast Guard marine inspector. Based on the findings of this examination, the due date of item 1 may be required to be completed sooner.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Construction/Loadline
Issued 15 August 1995 Resolved
A review of temporary repairs will be made prior to 16 February 1996 to ensure they are still satisfactory. If repairs are not sat, vessel is to be drydocked. In no case will temp repairs be allowed beyond 16 August 1996, at which time drydocking is required to complete permanent repairs.
Condition: Unknown
Due 15 August 1995
Resolved 15 August 1995
Navigation
Issued 30 May 1995 Resolved
Repair sound powered phone ringer from steering space to bridge.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Engineering
Issued 30 May 1995 Resolved
Repair #2 reduction gear oil pressure gage on bridge panel and repair #2 shaft tachometer.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Construction/Loadline
Issued 30 May 1995 Resolved
Repair ballast pump.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Electrical
Issued 30 May 1995 Resolved
Repair engine surging/hunting #2 SSD Generator. Generator currently inoperable.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Engineering
Issued 30 May 1995 Resolved
Submit plan to repair/modify holed keel coolers for main engines.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Fire Fighting
Issued 28 February 1995 Resolved
MAKE SELF CLOSURE OPERABLE FOR CASINO DECK EMERGENCY GEAR DOOR.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Fire Fighting
Issued 28 February 1995 Resolved
PROVIDE A-0 DOOR SILL FOR EMERGENCY SWITCHBOARD ROOM DOOR.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Fire Fighting
Issued 28 February 1995 Resolved
PROVIDE A-0 DOOR SILL FOR DOOR LOCATED IMMEDIATELY AFT OF PILOTHOUSE STAIRWAY ENCLOSURE.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Fire Fighting
Issued 28 February 1995 Resolved
PROVIDE A-0 DOOR SILL FOR MAIN DECK DINING ROOM STBD SIDE DOOR.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Fire Fighting
Issued 28 February 1995 Resolved
MAKE SELF CLOSURE OPERABLE FOR MAIN DECK DINING ROOM PORT SIDE DOOR.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Fire Fighting
Issued 28 February 1995 Resolved
PROVIDE A-15 CLOSURE FOR SLOT ROOM DUMB WAITER OPENING.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Fire Fighting
Issued 28 February 1995 Resolved
PROVIDE A-0 DOOR SILL FOR MAIN DECK SURVEILLANCE ROOM DOOR.
Condition: Unknown
Due 28 February 1995
Resolved 28 February 1995
Engineering
Issued 15 August 1994 Resolved
PROVIDE PROPER OPERATION OF THE PORT MAIN DIESEL ENGINE OVERSPEED DEVICE PRIOR TO DEPARTING THE PORT OF JACKSONVILLE, FL.
Condition: Unknown
Due 16 September 1994
Resolved 18 August 1994
Lifesaving
Issued 15 August 1994 Resolved
PROVIDE GENERAL ALARM AND LOUDSPEAKER ON SUN DECK PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Electrical
Issued 15 August 1994 Resolved
PROVE PROPER OPERATION OF #2 SHIPS SERVICE GENERATOR PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Electrical
Issued 15 August 1994 Resolved
PROVE PROPER OPERATION OF #2 SS GENERATOR. DEMONSTRATE OVERSPEED TRIP, LOWL/O ALARM, AND STOP TOGGLE SWITCH PRIOR TO DEPARTING THE PORT OF JACKSONVILLE, FL.
Condition: Unknown
Due 16 September 1994
Resolved 18 August 1994
Fire Fighting
Issued 15 August 1994 Resolved
PROVIDE EVIDENCE OF SERVICING FOR FIXED FIRE SYSTEMS PRIOR TO DEPARTING THEPORT OF JACKSONVILLE, FL.
Condition: Unknown
Due 16 September 1994
Resolved 18 August 1994
Engineering
Issued 15 August 1994 Resolved
PRESENT UPPER AIR RECEIVER FOR INSPECTION PRIOR TO DEPARTING THE PORT OF JACKSONVILLE, FL.
Condition: Unknown
Due 16 September 1994
Resolved 18 August 1994
Fire Fighting
Issued 15 August 1994 Resolved
CONDUCT FIRE AND BOAT DRILL WITH FULL CREW IN THE PRESENCE OF A USCG MARINEINSPECTOR PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Engineering
Issued 15 August 1994 Resolved
PROPERLY MOUNT FLOATING PC CARD IN PORT MAIN ENGINE ALARM J-BOX.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Fire Fighting
Issued 15 August 1994 Resolved
PROVIDE FIRE CONTROL PLAN TO [name withheld] FRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Documentation
Issued 15 August 1994 Resolved
PROVIDE RANDOM DRUG TESTING DOCUMENTATION WITH NEW VESSEL NAME.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Documentation
Issued 15 August 1994 Resolved
PROVIDE EMERGENCY EVACUATION PLAN TO [name withheld] PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Electrical
Issued 15 August 1994 Resolved
PROVE PROPER OPERATION OF ENGINEROOM FAN ENMERGENCY SHUTDOWN.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Accommodation/Occupational Safety
Issued 15 August 1994 Resolved
PROVIDE PLANS FOR ENGINEROOM VENTILATION MODIFICATION FOR APPROVAL.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Fire Fighting
Issued 15 August 1994 Resolved
INSTALL FIRE DAMPER IN BOW THRUSTER EXHAUST TRUNK.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Lifesaving
Issued 15 August 1994 Resolved
PRESENT FOR INSPECTION THE EMERGENCY EQUIPMENT REQUIRED BY 46 CFR 77.30.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Fire Fighting
Issued 15 August 1994 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH REQUIREMENTS OF 46 CFR 76.10-10 REGARDING LOW VELOCITY WATER SPRAY APPLICATORS.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Documentation
Issued 15 August 1994 Resolved
PROVIDE EVIDENCE OF VALID USCG DOCUMENTATION WITH NEW VESSEL NAME.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Documentation
Issued 15 August 1994 Resolved
PROVIDE EVIDENCE OF VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY PRIOR TO MOVING VESSEL.
Condition: Unknown
Due 16 September 1994
Resolved 18 August 1994
Fire Fighting
Issued 25 January 1994 Resolved
PROVIDE FIXED FIRE EXTINGUISHING SYSTEM FOR BOW THUSTER SPACE AS REQUIRED BY 46 CFR 76.05-20.
Condition: Unknown
Due 25 January 1994
Resolved 25 January 1994
Engineering
Issued 21 December 1993 Resolved
PROVIDE INSULATION FOR EMERGENCY GENERATOR EXHAUST AND TUBO-CHARGER.
Condition: Unknown
Due 21 December 1993
Resolved 21 December 1993
Engineering
Issued 21 December 1993 Resolved
MAKE REPAIRS TO PORT SIDE FUEL OIL REMOTE SHUTOFF.
Condition: Unknown
Due 21 December 1993
Resolved 21 December 1993
Lifesaving
Issued 21 December 1993 Resolved
PROVIDE CREW FOR FIRE DRILL, ABANDON SHIP DRILL AND MAN OVERBOARD DRILL.
Condition: Unknown
Due 30 December 1993
Resolved 4 January 1994
Engineering
Issued 21 December 1993 Resolved
PROVIDE INSULATION FOR BOW THUSTER ENGINE EXHAUST PIPING.
Condition: Unknown
Due 21 December 1993
Resolved 21 December 1993
Electrical
Issued 21 December 1993 Resolved
REMOVE DEAD END WIRING AND PROVIDE COVER FOR OPEN ELECTRIC BOX.
Condition: Unknown
Due 21 December 1993
Resolved 21 December 1993
Engineering
Issued 21 December 1993 Resolved
PROVIDE INSULATION FOR FORWARD GENERATOR EXHAUST IN ENGINE ROOM.
Condition: Unknown
Due 21 December 1993
Resolved 21 December 1993
Engineering
Issued 21 December 1993 Resolved
HAVE BOTH MAIN ENGINES READY FOR TESTING.
Condition: Unknown
Due 30 December 1993
Resolved 4 January 1994
Lifesaving
Issued 21 December 1993 Resolved
MAKE REPAIRS TO GALLEY VENT CLOSURE ON 01 DECK.
Condition: Unknown
Due 21 December 1993
Resolved 21 December 1993
Accommodation/Occupational Safety
Issued 14 September 1993 Resolved
demonstrate to the satisfaction of the cognizant OCMI the placement of tables and chairs for proper aisle width.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Documentation
Issued 14 September 1993 Resolved
Provide on baord a stamped approved copy with command letter of EEP.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Lifesaving
Issued 14 September 1993 Resolved
Hold fire and abandon drill in presence of Coast Guard Inspector
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Lifesaving
Issued 14 September 1993 Resolved
Provide on board to the satisfaction of the cognizant OCMI a motorized rescue boat.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Engineering
Issued 14 September 1993 Resolved
Provide a fixed container or enclosed deck area around the fuel oil fill onthe main deck aft in accordance with 33 CFR 155.360. The containment must have a capacity of at least one-half barrel.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Engineering
Issued 14 September 1993 Resolved
Provide Oil Transfer Proceduces that meet the requirements of 33 CFR 155.720.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Construction/Loadline
Issued 14 September 1993 Resolved
Provide an oil pollution discharge placard in a conspicuos place in each machinery space or at the bilge and ballast pump control station in accoradance with 33 CFR 155.450.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Lifesaving
Issued 14 September 1993 Resolved
Provide 53 CG appoved Type I child's PFD in accordance with 46 CFR 75.40-5 or Vessel's COI will be amended to allow adult passengers only.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Lifesaving
Issued 14 September 1993 Resolved
Secure all galley, bar, food serving and gaming equipment to prevent shifting when vessel is underway.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Electrical
Issued 14 September 1993 Resolved
Provide illumination for inflatable liferafts lanching operations in accordance with 46 CFR 75.50-15 and 111.75-16.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Fire Fighting
Issued 14 September 1993 Resolved
Provide instructions for the operation of the fixed Halon fire extinguishing system which includes schematic diagram of the system and alterate methods of dischargeing in accordance with 46 CFR 76.15-10.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Fire Fighting
Issued 14 September 1993 Resolved
Provide a wrench at the fixed Halon fire extinguishing system pull box located in the main deck dinning area for the hatch leading into the Halon bottle stowage area.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Engineering
Issued 14 September 1993 Resolved
Provide in the wheelhouse and at the engineroom control station a propellerspeed and direction indicatior for each shaft in accordance with 46 CFR 113.37-5(a).
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Construction/Loadline
Issued 14 September 1993 Resolved
Provide equipment for the control of oil discharges from machinery space bilges in accordance with 33 CFR 155.360. This includes an oily-water seperator, oily residue tank and the piping for discharge to a reception facility.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Accommodation/Occupational Safety
Issued 14 September 1993 Resolved
Provide positive means to ensure closure of the sewage overboard discharge valve, to prevent the discharge of untreated sewage into the waters of the United States, including the territirial seas in accordance with 33 CFR 159.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Documentation
Issued 14 September 1993 Resolved
Submitt stability caluculations for use of port/stbd void tanks FR 12-22 for use as ballast tanks.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Construction/Loadline
Issued 14 September 1993 Resolved
Provide a standard discharge shore connection for the discharge to reciption facilities, or oily wastes from machinery space bilges in accordance with 33 CFR 155.430.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Lifesaving
Issued 14 September 1993 Resolved
Provide ten (10), fifty (50) person inflatable liferafts with launching appliances as required by the Safety Plan (Dwg No 180-SAFE) which was appoved by MSO Mobile, Al on 14 Sept 1993 and in accordance with 46 CFR 75.10-25.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Lifesaving
Issued 14 September 1993 Resolved
Provide on board a Coast Guard appoved copy of The Emergency Evacuation Plan with comment letters in accordance with Navigation and Vessel Inspection Circular No. 14-91 (NVIC 14-91).
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Engineering
Issued 14 September 1993 Resolved
Gas Free and provide Gas Free Certificate of former fuel oil tank FR 58-69.Blank off all fill connections to tank and connections to fuel oil system.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Lifesaving
Issued 14 September 1993 Resolved
Provide on board a motorized rescue boat capable of being readily launched and easily maneuvered. The embarkation and launching area shall meet the lighting requirements of 46 CFR 75.50-15.
Condition: Unknown
Due 14 October 1993
Resolved 26 October 1993
Lifesaving
Issued 14 September 1993 Resolved
Demonstrate that the placement of the tables and chairs in the main deck passenger dinning area will allow for proper egress.
Condition: Unknown
Due 14 October 1993
Resolved 26 October 1993
Accommodation/Occupational Safety
Issued 14 September 1993 Resolved
Provide a waste management plan and placards in accordance with 33 CFR 151.57 and 151.59.
Condition: Unknown
Due 14 October 1993
Resolved 26 October 1993
Construction/Loadline
Issued 14 September 1993 Resolved
Seal opening in the fo'c'sle deck which leads into the main deck A/C room, to comply with the structural fire protection requirements of 46 CFR 72.05-10.
Condition: Unknown
Due 15 November 1993
Resolved 26 October 1993
Documentation
Issued 14 September 1993 Resolved
Provide a Station Bill that meets the requirements of 46 CFR 78.13.
Condition: Unknown
Due 14 October 1993
Resolved 25 October 1993
Fire Fighting
Issued 14 September 1993 Resolved
Double swing fire doors in "A" Class bulkheads shall have a maximum clearance of 1/8 inch at the tops, sides and between doors in accordance with 46 CFR 72.05-25(b)(7).
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Construction/Loadline
Issued 14 September 1993 Resolved
Demonstrate that closures/dampers are installed in the ventalation trunk that connects the engine room space and the forward machinery space which comply with the requirements of 46 CFR 72.05-50 and 76.15-35.
Condition: Unknown
Due 14 October 1993
Resolved 26 October 1993
Lifesaving
Issued 14 September 1993 Resolved
Hold satisfactory fire, abandon ship and person overboard drills in the presence of a Coast Guard Inspector.
Condition: Unknown
Due 14 October 1993
Resolved 26 October 1993
Fire Fighting
Issued 14 September 1993 Resolved
All fire doors opening into the stairway enclosure on the main foo'c'sle_x001C_ and upper deck and the galley fire doors must meet the latch requiements of46 CFR 72.05-25(b).
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Navigation
Issued 14 September 1993 Resolved
Repostion Navigation lights to comply with the horizontal positioning and the spacing of lights in accodance with International Navigation Rules 33 CFR 81 Appendix A, Annex I 3.(a).
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993

Casualty record · 4

24 July 2006Routine · role: Involved in a Marine Casualty · activity 2723521
1 November 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3855678
29 April 2007Routine · role: Involved in a Marine Casualty · activity 2919042
13 September 2010Routine · role: Subject to Marine Inspection · activity 3848803
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DIAMOND GIRL II (2006–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.