Records from 2019 to 2026. Most recent: inspection, 8 January 2026.
Inspection history · 15
8 January 2026
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8289997
17 September 2025
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8237671
11 December 2024
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8049621
12 November 2024
Hull Examination · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8029902
6 February 2024
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7861624
30 January 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7857133
20 November 2023
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7826554
11 January 2023
Annual Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7621728
18 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579716
11 August 2022
In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7529888
12 January 2022
Internal Structural Exam · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7378654
16 December 2021
Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7368610
15 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7174295
15 January 2020
Drydock Exam · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6888980
13 December 2019
Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6885525
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 November 2023
Resolved
One portable fire extinguisher is not sufficiently charged, two portable fire extinguishers have not been properly maintained. Portable extinguishers must be inspected and maintained in accordance with NFPA 10. Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers.
46CFR176.810
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 November 2023
Resolution: All required portable fire extinguishers are now sufficiently charged, and have been properly maintained in accordance with NFPA 10.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 November 2023
Resolved
One of three fire buckets are inoperable due to cracking. A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2-1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
46CFR181.610
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 November 2023
Resolution: Vessel now has three 9.5 liter (2-1/2 gallon) buckets, with an attached lanyard, with the words “FIRE BUCKET” stenciled in a contrasting color on each bucket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 November 2023
Resolved
Vessel is missing one child size life jacket, adult and
child size life jackets are not separated, and not the
life jacket stowage areas are not properly marked.A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
46CFR180.71
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 November 2023
Resolution: Vessel now has required quantity of child size life jacket, adult and child size life jackets are now separated, and the life jacket stowage areas are now properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 November 2023
Resolved
The condition of the ring life buoy allows for water saturation on the interior of the ring life buoy, the ring life buoy life line is 50' in length, the floating light is non operational and in non-serviceable condition, the floating light line in worn and requires replacement. A vessel must have one or more ring life buoys as follows: (1) A vessel of not more than 7.9 meters (26 feet) in length must carry a minimum of one life buoy of not less than 510 millimeters (20 inches) in diameter; Each lifeline must be buoyant, be at least 60' in length, non-kinking, be at least 5/16" diameter, have a breaking strength of at least 1124 pounds, and be resistant to UV light. Each floating waterlight must be approved in accordance with § 161.010. Each ring life buoy with a floating waterlight must have a lanyard of at least 3' in length, but not more than 6' securing the waterlight around the body of the ring life buoy and floating water light must be attached to lanyard w/corrosion resistant clip.
46CFR180.70
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 November 2023
Resolution: Vessel replaced properly marked ring life buoy with correct 60' lifeline and floating water light with correct lanyard and clip.