Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it44999 - Dead Weight, Metric Ton 56664 - Displacement, Metric Ton 29991 - Convention (Subpart B), Gross Ton 12836 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 March 2020Resolved
The fixed gas detection equipment shall be so designed that it may be readily tested. The ship's crew attempted to test the fixed gas detection system several times using 50% LEL Gas (Methane) supplied to the gas-analyzing cabinet sample pick-up. The system shuts down, as designed, when it detects 30% LEL in the cabinet. Therefore, the crew is unable to show the analyzer correctly measures gas supplied to it. - 74 SOLAS ('14 cons.) II-2/4.5.7.3.1 & FSS Code Ch. 16/2.2.3.4
Action required: 15 - Rectify deficiencies by next port
Resolved 24 March 2020
Resolution: Received, reviewed, and accepted a class report from ABS stating that the two deficiencies identified during the COC exam were rectified. The class report is uploaded into "documents".
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 March 2020Resolved
The company should establish procedures to ensure the ship is maintained in conformity with relevant rules and regulations. The company requires the crew to conduct monthly function test of the fixed gas-detection system. The crew does not have procedures to make the test. - ISM Code (2018 ed.) Part A/10.1
Action required: 15 - Rectify deficiencies by next port
Resolved 24 March 2020
Resolution: Received, reviewed, and accepted a class report from ABS stating that the two deficiencies identified during the COC exam were rectified. The class report is uploaded into "documents".
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.