AMERICAN MELODY

AMERICAN MELODY is a 2021 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2020, most recently in March 2026, along with 5 deficiencies.

Records from 2020 to 2026. Most recent: inspection, 28 March 2026.

Built
2021
Last inspected
28 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 March 2026
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM4300
1603793
Flag
UNITED STATES
Maury page id
psix-1603793

Documentation record

Registered dimensions (L × B × D)302.3 ft × 57.0 ft × 12.3 ft
Registered tonnagegross 99 / net 99
ITC dimensions (L × B × D)302.3 ft × 57.0 ft × 12.3 ft
ITC tonnagegross 5,062 / net 1,518
BuilderCHESAPEAKE SHIPBUILDING CORP · Salisbury, MD, UNITED STATES · built 2021
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 5 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2184 - Displacement, Gross Ton
5062 - Convention (Subpart B), Gross Ton
1518 - Convention (Subpart B), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
99 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

28 March 2026 In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8333998
17 March 2026 MTSA Verification · COI Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8323121
22 May 2025 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8141606
8 April 2024 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7891546
14 June 2023 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7715026
11 May 2022 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7448490
20 August 2021 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7257001
16 August 2021 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7288154
1 June 2020 Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7218666

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 May 2025 Resolved
THE CONSTRUCTION AND ARRANGEMENT OF A VESSEL MUST ALLOW THE SAFE OPERATION OF THE VESSEL IN ACCORDANCE WITH THE TERMS OF THE CERTIFICATE OF INSPECTION GIVING CONSIDERATION TO PROVISIONS FOR A SEAWORTHY HULL, PROTECTION AGAINST FIRE, MEANS OF ESCAPE IN CASE OF A SUDDEN UNEXPECTED CASUALTY, GUARDS AND RAILS IN HAZARDOUS PLACES, VENTILATION OF ENCLOSED SPACES, AND NECESSARY FACILITIES FOR PASSENGERS AND CREW. MI WITNESSED THE A60 DOOR TO ENTER THE ENGINE ROOM WAS INCAPABLE OF OPENING AND CLOSING AS INTENDED. THE VESSEL IS AUTHORIZED TO MAKE TEMP REPAIRS AND PERMANENT REPAIRS MUST BE CONDUCTED AT NEXT DRY DOCK.
Action required: 705 - Other - as specified
Resolved 17 March 2026
Resolution: Fire door was permanently fixed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 June 2023 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in spaces listed in 46 CFR 119.530. Due to concrete ballast installed in the bow thruster space, high water cannot be detected in the forward of the space or between the tunnels. Install alarms to indicate high water by next required dry dock exam.
Action required: 705 - Other - as specified
Due 31 July 2026
Resolved 27 May 2025
Resolution: Three separate bilge alarms were installed forward, aft, and between the thruster tunnels. MI's witnessed successful test of all alarms.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 May 2022 Resolved
Each inlet that penetrates the hull below the waterline must have a means to prevent water from entering the vessel and to make them watertight. Although the penetration has a valve installed, there is no attached piping or system to the valve that would prevent water intrusion if the valve is opened or fails. Ensure watertight integrity by installing a blank flange to the open end of the hull penetration piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 16 May 2022
Resolution: Blank flange installed on penetration/valve.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 May 2022 Resolved
The owner or managing operator shall provide satisfactory evidence of required servicing of portable fire extinguisher. Two portable extinguishers in forward machinery space had not been serviced. Service fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 16 May 2022
Resolution: Fire extingusihers serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2022 Resolved
Each life jacket must be marked clearly legible block capital letters with the vessel's name. Several life jackets were found to be missing labels. Label life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 16 May 2022
Resolution: Life jackets labeled.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.