MAURY USCG vessel records
← All vessels

CREOLE SUN

CREOLE SUN is a 2019 tank ship. The Coast Guard has recorded 11 inspections since 2020, most recently in June 2026, along with 5 deficiencies and 2 operational controls.

Records from 2020 to 2026. Most recent: inspection, 1 June 2026.

Built
2019
Last inspected
1 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9850214
1603804
Flag
PANAMA
Maury page id
psix-1603804

Documentation record

Tonnage as PSIX records it49760 - Dead Weight, Metric Ton
60787 - Displacement, Metric Ton
29987 - Convention (Subpart B), Gross Ton
13587 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

11 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

1 June 2026 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8375389
20 June 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8150907
15 May 2025 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8136540
5 September 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7996651
28 April 2024 Administrative Inspection · PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7901201
14 August 2022 COC-CHEM & TVE Annual
Type not classified · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7528692
1 March 2022 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7403892
8 February 2022 In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7393008
9 August 2021 COC-CHEM & TVE Renew
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7273947
22 January 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7129279
22 April 2020 COC-CHEM & TVE Renew · PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6940338

Deficiency record · 5

04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 15 May 2025 Resolved
Seafarers, on being assigned to any of its ships, are familiarized with their specific duties and with all ship arrangements, installations, equipment, procedures and ship characteristics that are relevant to their routine or emergency duties. Crew was unable to demonstrate adequate knowledge and familiarization of their specific duties and ship arrangements in regards to the fuel handling and delivery system as required per IGF Code. STCW 1/14.1.5 (Code 17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2025
Resolved 18 May 2025
Resolution: PSCO received objective evidence that additional crew training was conducted and verified the crews knowledge of the system and emergency duties during inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 15 May 2025 Resolved
The technical and/or operational nature of deficiencies 02, 03, 04, and 05 provide objective evidence of a serious failure, or lack of effectiveness, of the implementation of the ISM Code. A safety management audit carried out by the Administration or the RO, with a corresponding report of findings satisfactory to the OCMI must be submitted prior to clearance of this deficiency and release from detention. 74 SOLAS IX.3.1, ISM Code 10.2.2 (Code 30abc)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 18 May 2025
Resolution: A safety management audit was completed by the RO on 16MAY. A copy of the report has been uploaded under documents for this Activity.
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 15 May 2025 Resolved
Suitable control, alarm, monitoring and shutdown systems shall be provided to ensure safe and reliable operation. Crew was unable to demonstrate to the PSCO satisfactory operation or testing of emergency shutdowns, alarms, and equipment as a part of the fuel handling and delivery system as required per IGF Code. SOLAS (20) II-1/57, IGF 3.2.13 (Code 30ac)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 18 May 2025
Resolution: PSCO observed satisfactory operation of tank high level alarms, emergency shutdowns, flame/fire detection, and gas detection during inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 15 May 2025 Resolved
Drills and emergency exercises on board shall be conducted at regular intervals. The PSCO identified multiple emergency situations/drills that shall be carried out every 3 months in accordance with their Safety Management System, including MEOH pipe burst and leakage, gas detection, accidental MEOH spill in the engine room, and gas detection in double wall piping. The PSCO was not provided documentation that the drills required by the SMS were being conducted. 74 SOLAS (20) II-1/57, IGF 17 (code 30ac)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 18 May 2025
Resolution: The PSCO received objective evidence that a satisfactory MEOH drill was conducted. Additionally, the SMS was updated to reflect additional requirements for these drills to be completed on a quarterly basis.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 15 May 2025 Resolved
Maintenance procedures and information for all gas related installations shall be available on board. The vessel’s Safety Management System (SMS) required spray test gas (vapor) appropriate for methanol to test sensors in installed double wall piping. The PSCO was not provided any proof that the test gas was onboard or that testing would conducted in accordance with the SMS and maintenance plan. SOLAS (20) II-1/57, IGF 18.2.2 (Code 17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2025
Resolution: PSCO received objective evidence that test gas was present on board and verified during the inspection the functionality of methanol sensors throughout the fuel system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.