APL CYPRINE

APL CYPRINE is a freight ship. The Coast Guard has recorded 36 inspections since 2001, most recently in May 2017, along with 18 deficiencies — 1 with no resolution recorded —, 1 operational control and 7 casualty investigations between 2010 and 2015.

Records from 2001 to 2017. Most recent: inspection, 17 May 2017.

Built
Not recorded
Last inspected
17 May 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9139725 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE8293
Flag
SINGAPORE
367403790 (licence lapsed)
Maury page id
psix-16039

Inspections, by type

…with no type recorded11
…past their stated due date1
Years with a record 11 calendar years (2001–2017)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it65475 - Convention (Subpart B), Gross Ton
0 - Simplified, Gross Ton
0 - Simplified, Net Ton
28825 - Convention (Subpart B), Net Ton
61664 - Dead Weight, Ton
84629 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE8293MMSI 367403790 · cancelled · compulsorily equipped · granted 9 April 2009, cancelled 5 January 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

APALACHEE WARRIOR Commercial Fishing Vessel · MISLE 164790 · 30 December 2011 · activity 4233068

Inspection history · 36

17 May 2017 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6148290
21 December 2015 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5785227
4 December 2015 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5775137
26 October 2015 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 5750546
21 October 2015 Type not recorded
No type recorded · Activities Europe · Activity 5747476
14 October 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5742175
28 September 2015 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5731108
11 August 2015 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5212401
28 August 2014 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4968804
17 June 2014 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4891083
3 March 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4808863
3 July 2012 Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4366104
9 January 2012 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4221275
30 December 2011 Damage Survey
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4218761
30 December 2011 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4233068
24 December 2011 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4213532
22 December 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4212567
21 August 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4118736
14 February 2011 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3937140
13 February 2011 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3944347
10 February 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3942601
19 December 2010 Underwater Inspection in lieu of Drydock
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3915201
7 November 2010 Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 3873416
17 October 2010 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3873832
7 October 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3865529
27 September 2010 Type not recorded
No type recorded · Activities Europe · Activity 3860891
11 December 2009 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3648418
4 May 2009 Reflagging & Initial Certification · MTSA/ISPS Verification · MARPOL Annex VI Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3463664
4 May 2009 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3467144
14 November 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3362828
4 November 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3092942
19 August 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1663068
8 July 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1642435
12 April 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1604299
3 March 2002 Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1490677
24 March 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 288481

Deficiency record · 18

Lifesaving › Launching Appliances › Winch
Issued 14 October 2015 Resolved
Make the approved repairs needed to the davit/raising system for the #1 lifeboat so the lifeboat can be raised and cradled as designed prior to departure from Singapore.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2015
Resolved 23 October 2015
Resolution: Vessel made necessary repairs to #1 Life-boat winch and proved proper lowering and cradling operations in witness of attending ABS Class Surveyor. Class Survey Report embedded within this activity.
Deck/Cargo › Ballast › Piping
Issued 11 August 2015 No resolution recorded
The #2 ballast pump discharge piping has a 1" hole. Vessel has made temporary repairs to the satisfaction of a Coast Guard Marine Inspector. Vessel is now required to make permanent repairs to the satisfaction of a Coast Guard Marine Inspector.
Due 31 December 2015 — due date passed with no resolution recorded
Construction/Loadline › Structures › Superstructure
Issued 28 August 2014 Resolved
Forwardmost supporting stanchion of Deck "A" platform (stbd side) was found to have fractures at the longitudinal hatch coaming web plate. Fractures were also found in the connection of the bunker hose support to the stanchion and in the transversal bracket located below the longitudinal hatch coamings web plate. Provide repair proposal and repair back to equal support or as original.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 23 September 2014
Resolution: Cleared; received ABS class report.
Construction/Loadline › Structures › Superstructure
Issued 28 August 2014 Resolved
Fowardmost supporting stanchion of the Deck "A" platform, located on the upper deck, (port side) was found fractured in the lower connection to the longitudinal hatch coamings web plate. Provide repair proposal and repair back to equal support or as original. Make available to the satisfaction of attending CG marine inspector.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 23 September 2014
Resolution: Cleared; received ABS class report.
Engineering › Compressed Air System (start air) › Compressor
Issued 28 August 2014 Resolved
Start air compressor foundations #1 and #3 show visible cracks where the motor meets the compressor. Properly repair and make available to attending CG marine inspector.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 2 September 2014
Resolution: Recieved ABS final report testifying to repairs made to both support pads.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 March 2014 Resolved
Renew A-60 self closing door to Engine Control Room. Door, in current state, can no longer provide required structural fire protection as initially intended.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 17 June 2014
Resolution: Door installed ABS aslo in attendence
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 30 December 2011 Resolved
4 Holes have been drill stopped and a doubler plate installed over damaged area in Bay 45-47 Port side Fr # 74 and Fr # 84 approximately 50 and 45 ft port of centerline. ABS has issued a condition of Class and will determine ETR for permanant repairs at a later date.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 January 2012
Resolution: Rcvd ABS Class report of permanant repairs
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 14 February 2011 Resolved
Provide documentation for periodically unmanned machinery spaces and approved periodic test procedures. Vessel engine room shall be manned 24 hours a day until periodic test procedures have been approved and verified by the Cognizant officer in Charge, Marine inspections.
Action required: 705 - Other - as specified
Resolved 8 April 2011
Resolution: CG 835 rescinded pending MSP guidance from CG headquarters.
Accommodation/Occupational Safety › Heating › Piping
Issued 11 December 2009 Resolved
Hole in hot water tank condensate line starboard side lower level in engineroom overhead. Make permanent repairs prior to sailing foreign.
Due 17 December 2009
Resolved 17 December 2009
Resolution: Received fax dated 12/17/09 from ABS attesting to repair by crew and found satisfactory. Deficiency cleared.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 December 2009 Resolved
OWS inoperable. Make permanent repairs prior to sailing foreign. Repair guard on OWS pump.
Due 17 December 2009
Resolved 17 December 2009
Resolution: Received fax from ABS dated 12/17/09 attesting to calibration of OCM on 10DEC09. ABS tested OWS/OCM and found in good working order. Deficiency cleared.
Engineering › Pressure Vessel › Support
Issued 11 December 2009 Resolved
Three refrigerant bottles located in the engineroom aer not properly stowed. Bottles are tied off using line and not mounted in rack having potential as a missle hazard.
Due 17 December 2009
Resolved 17 December 2009
Resolution: Received fax from ABS dated 12/17/09 attesting to proper securing of all refrigerant bottles. Deficiency cleared.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 11 December 2009 Resolved
The 220 volt emergency panel showed a ground. Ground detected on elevator shaft emergency lighting. Repair ground prior to sailing foreign.
Due 17 December 2009
Resolved 17 December 2009
Resolution: Received fax from ABS dated 12/17/09 attesting to correction of fault and proper operation of ground detection system. Deficiency cleared.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 4 May 2009 Resolved
In compliance with waiver issued by Comdt, postponing hydro testing of vessel's CO2 bottles until next scheduled dry-dock (31DEC2012), the 6 pilot bottles shall be hydro-tested NLT 6JUL09.
Condition: Unknown
Due 9 July 2009
Resolved 3 June 2009
Resolution: Received report from 3rd party company that cylinders were hydro tested satisfactorily.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 May 2009 Resolved
Having complied with the stipulations contained in USCG HQ (CG-543) letter dated 08May09, the hydrostatic testing of the vessel's high pressure CO2 bottles is extended until the next scheduled dry-docking period.
Condition: Unknown
Due 28 February 2013
Resolved 20 March 2013
Resolution: All of the CO2 cylinders were hydro tested, vessel retains documentation from 3rd party.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 November 2007 Resolved
Several emergency lights leading to the lifeboats were non-operational. This poses a safety hazard. SOLAS 97 Chap III Reg 11.5. 10c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2007
Resolution: Crewmembers changed out light bulbs prior to inspectors departing.
Operations/Management › Drills/Instruction
Issued 12 April 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2002
Resolved 13 April 2002
Resolution: CREW CONDUCTED PROPER ABANDON SHIP DRILL TO THE SATISFACTION OF MARINE INSPECTOR.
Operations/Management › Drills/Instruction › Fire
Issued 12 April 2002 Resolved
CREW FAILED FIRE DRILL TWICE DUE TO THE LACK OF FAMILIARITY WITH THEIR DUTIES DURING FIRE DRILL IN ACCORDANCE WITH SOLAS 74 XI/4. VESSEL WAS DETAINED UNTIL CREW CAN CONDUCTED SATISFACTORILY FIRE DRILL.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2002
Resolved 12 April 2002
Resolution: CREW CONDUCTED A PROPER FIRE DRILL AS APPROVED BY MARINE INSPECTOR.
Lifesaving › Lifeboat › Stability
Issued 12 April 2002 Resolved
LIFEBOAT UNABLE TO BE LAUNCHED AS REQUIRED BY SOLAS 74 III/18.3.6. VESSEL MUST HAVE LIFEBOAT SURVEYED BY CLASS PRIOR TO USCG REINSPECTION IN LONG BEACH.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2002
Resolved 13 April 2002
Resolution: CREW WAS ABLE TO LAUNCH LIFEBOAT SAFELY AND IN ACCORDANCE WITH SOLAS DURING ABANDON SHIP DRILL

Casualty record · 7

26 June 2010Routine · role: Involved in a Marine Casualty · activity 3788451
27 September 2010Routine · role: Involved in a Marine Casualty · activity 3860891
30 December 2011Routine · role: Involved in a Marine Casualty · activity 4233068
1 March 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4544206
27 August 2013Routine · role: Involved in a Marine Casualty · activity 4780714
2 September 2013Routine · role: Involved in a Marine Casualty · activity 4783655
21 October 2015Routine · role: Involved in a Marine Casualty · activity 5747476
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.