Records from 2019 to 2026. Most recent: inspection, 10 June 2026.
Documentation record
Registered dimensions (L × B × D)54.0 ft × 17.0 ft × 4.0 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE BOATS INC · CRISFIELD, MD, UNITED STATES · built 2020
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portWASHINGTON, DC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2026
Resolved
13104 - A visual and audible alarm must be provided at the operating station to indicate a high water level. The visual indicator for the high water level alarm in the fuel room was inoperable.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2026
Resolution: MI witnessed proper operation of bilge alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 28 March 2023
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant OCMI. Vessel has anchor and line unsecured and not properly stowed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: Vessel has anchor and line secured and properly stowed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. E-Fuel shutoffs were not labeled.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: E-Fuel shutoffs were labeled.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 March 2023
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Labeling was incorrect.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: Corrected upper deck labeling.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 March 2023
Resolved
Masthead light means a white light placed over the fore and aft centerline of the vessel showing an unbroken light over an arc of the horizon of 225 degrees, except that on a vessel of less than 12 meters in length. Sternlight means a white light placed as nearly as practicable at the stern showing an unbroken light over an arc of the horizon of 135 degrees. Vessel is required to have both. It only had an all around light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: Nav lights repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 March 2023
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Vessel had no container.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: Proper container for distress signals, onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 March 2023
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel was carrying the wrong type of flares.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: Proper flares were onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. There were no viable closures for the engine compartment vents.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: closures for the engine compartment vents were established.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 March 2023
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Fire pump pressure gauge was inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: Fire pump pressure gauge was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 March 2023
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. (02) Waterlight lines were not the right type or size.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: (02) lines for ring buoy water light was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 March 2023
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, each hose must Have fittings of brass or other suitable corrosion-resistant material that comply with NFPA 1963. Hose does not have proper fitting connection to the vessel deck, and spanner wrench is missing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: A new proper fitting connection to the vessel's deck, and spanner wrench were added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 December 2019
Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Vessel was missing 01 Child life jacket.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: Vessel added 01 additional child life jacket.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 December 2019
Resolved
A pre-engineered fixed gas fire extinguishing system must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space and Be installed in accordance with the manufacturer's instructions. Pre-engineered system did not shut down Port/STBD MDEs.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
Resolution: Pre-engineered system was properly set up.