SCF LA PEROUSE is a tank ship. The Coast Guard has recorded 6 inspections since 2020, most recently in May 2021, along with 4 deficiencies and 1 operational control.
Records from 2020 to 2021. Most recent: inspection, 12 May 2021.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it92923 - Dead Weight, Metric Ton 116779 - Convention (Subpart B), Gross Ton 35033 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 6
12 May 2021Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7195429
16 April 2021PSC B · Ballast Water Examination · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7174111
16 April 2021Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7180415
15 March 2021Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7156534
20 May 2020Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6957183
24 March 2020COC-GAS Renew · PSC A
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6928179
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2021Resolved
The deck water spray system shall be capable of covering all areas mentioned in regulation 11.3.1. PCO found that the water spray system covering the forward lifraft was inoperable. 74SOLAS(20)VII/13.1 & 2016 IGC 11.3.2.1
Action required: 10 - Deficiency Rectified
Resolved 16 April 2021
Resolution: Vessel found rusted out restricted orifice and rust build-up; replaced restricted orifice and repoved rust accumulation from piping. Witnessed satisfactory test of water spray system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2021Resolved
Electrical installations shall be in accordance with recognized standards. PSCO found that junction box 10 (JB10) of the reliquification plant was missing certified cable gland/plug. 74SOLAS(20)VII/13.1 & 2016 IGC 10.2.2
International Certificate of Fitness shall be drawn up in the form corresponding to the model given in appendix 2. PSCO found that the certificate was missing tank plan. 74SOLAS(20)VII/13.1 & 2016 IGC 1.4.4.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 May 2021
Resolution: Vessel provided a copy of approved tank plan; ICOF was amended to reflect and the RO stamped approved.
The ship shall be provided with copies of suitably detailed Cargo System Operational Manuals approved by the Administration. PSO found that the Cargo Operations Manual was not approved by the Administration. 74SOLAS(20)VII/13.1 & IGC 2016 18.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 May 2021
Resolution: Vessel's RO approved the Cargo Operations Manual.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.