SILVER MOON is a passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2020, most recently in May 2026, along with 6 deficiencies and 1 operational control.
Records from 2020 to 2026. Most recent: inspection, 11 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it40844 - Convention (Subpart B), Gross Ton 5119 - Dead Weight, Ton 812 - Displacement, Ton 14170 - Convention (Subpart B), Net Ton 40844 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
11 May 2026PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8361196
1 June 2025Ballast Water Examination · COC-CVE Quarterly · PSC B
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 May 2026Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed flammable liquids stored in the Deck 5 Carpenter workshops (Cat. 13), which is prohibited without approved storage cabinets.
74 SOLAS 20 II-2/9.2.2.3.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2026
Resolution: Corrected prior to conclusion of the exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 May 2026Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. PSCO observed the following doors do not latch fully closed: A60.11.04, A60.5.34.
74 SOLAS 20 II-2/9.4.1.1.5.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2026
Resolution: Vsl corrected prior to conclusion of exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2026Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed exposed wiring on low location lighting on multiple levels in crew stairway #4.
74 SOLAS 20-II-1/40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2026
Resolved 12 June 2026
Resolution: Vessel provided proof via e-mail of replacement end caps for low location lighting.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 December 2024Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO observed multiple double leaf doors throughout the vessel failed to properly close, thus not meeting the time requirements provided above. FD A60 4.12, FD A0 4.14, and FD A60 5.10.
74 SOLAS 20 II-2/9.4.1.1.5.2
Action required: 10 - Deficiency Rectified
Due 6 December 2024
Resolved 6 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 November 2022Resolved
Doors required to be self closing shall not be fitted with hold back hooks. Several A and B class doors through the vessel had hold back devices to include hooks, wedges and tied with line preventing the door from self closing. 02 doors to launderette spaces had magnetic holdbacks that needed to be manually released. Additionally the fire door leading from the forward mooring area had a large carpet installed which caught, preventing the door form closing.
74SOLAS 20 II-2/9.4.2.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 5 January 2023
Resolution: Hold backs and carpeting were removed during examination.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 November 2022Resolved
Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler system of an approved type complying with the requirements of the FSS Code in all control stations, accomodation and service spaces, including corridors and stariways. A guage indicating the pressure in the system shall be provided at each section stop valve. Guage at section valve A08-3 was not indicating the correct pressure.
74 SOLAS 20 II-2/10.6.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 January 2023
Resolution: Replaced gauge.