← All vessels
SILVER MOON
Passenger (Inspected) · Passenger Ship class · USCG Arctic District (CGD-A) · Other hulls named SILVER MOON
SILVER MOON is a passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2020, most recently in May 2026, along with 6 deficiencies and 1 operational control.
Records from 2020 to 2026. Most recent: inspection, 11 May 2026.
- Built
- Not recorded
- Last inspected
- 11 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9838618 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6DM6
1606083
Flag
BAHAMAS, THE
—
Maury page id
psix-1606083
Inspections, by type
…with no type recorded1
Years with a record
7 calendar years (2020–2026)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it40844 - Convention (Subpart B), Gross Ton
5119 - Dead Weight, Ton
812 - Displacement, Ton
14170 - Convention (Subpart B), Net Ton
40844 - Simplified, Gross Ton
5119 - Dead Weight, Ton
812 - Displacement, Ton
14170 - Convention (Subpart B), Net Ton
40844 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
11 May 2026
PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8361196
1 June 2025
Ballast Water Examination · COC-CVE Quarterly · PSC B
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8149114
6 December 2024
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8043029
5 January 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7616746
2 January 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7615305
28 November 2022
COC-CVE Annual
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7600275
7 March 2022
Bulk Liquid Transfer Monitor
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7407010
29 November 2021
COC-CVE Initial · PSC A · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7358664
26 October 2021
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7340024
12 February 2020
COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 6907539
Deficiency record · 6
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 May 2026
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed flammable liquids stored in the Deck 5 Carpenter workshops (Cat. 13), which is prohibited without approved storage cabinets.
74 SOLAS 20 II-2/9.2.2.3.2.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 May 2026
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. PSCO observed the following doors do not latch fully closed: A60.11.04, A60.5.34.
74 SOLAS 20 II-2/9.4.1.1.5.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2026
Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed exposed wiring on low location lighting on multiple levels in crew stairway #4.
74 SOLAS 20-II-1/40.1.3
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 December 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO observed multiple double leaf doors throughout the vessel failed to properly close, thus not meeting the time requirements provided above. FD A60 4.12, FD A0 4.14, and FD A60 5.10.
74 SOLAS 20 II-2/9.4.1.1.5.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 November 2022
Resolved
Doors required to be self closing shall not be fitted with hold back hooks. Several A and B class doors through the vessel had hold back devices to include hooks, wedges and tied with line preventing the door from self closing. 02 doors to launderette spaces had magnetic holdbacks that needed to be manually released. Additionally the fire door leading from the forward mooring area had a large carpet installed which caught, preventing the door form closing.
74SOLAS 20 II-2/9.4.2.2
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 November 2022
Resolved
Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler system of an approved type complying with the requirements of the FSS Code in all control stations, accomodation and service spaces, including corridors and stariways. A guage indicating the pressure in the system shall be provided at each section stop valve. Guage at section valve A08-3 was not indicating the correct pressure.
74 SOLAS 20 II-2/10.6.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.