MAURY USCG vessel records
← All vessels

LIBERTY NATIONAL I

LIBERTY NATIONAL I is a 2020 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2019, most recently in November 2025, along with 3 deficiencies.

Records from 2019 to 2025. Most recent: inspection, 3 November 2025.

Built
2020
Last inspected
3 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDP3295
1606098
Flag
UNITED STATES
Maury page id
psix-1606098

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 7 calendar years (2019–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 15.0 ft × 4.3 ft
Registered tonnagegross 13 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE USA INC · PORT ANGELES, WA, UNITED STATES · built 2020
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portJERSEY CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

3 November 2025 COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8258234
18 November 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8036217
13 November 2024 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8034022
7 November 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8032040
2 November 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7819349
2 November 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7579240
24 October 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7579235
1 November 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7343169
24 November 2020 COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7097957
15 August 2019 Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7038743

Deficiency record · 3

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 November 2024 Resolved
(1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years; and This vessel was due for drydock no later than 31 OCT 2024 as indicated on page 2 of COI. Schedule a USCG Drydock Inspection through [email withheld] to clear. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2024
Resolution: Completed credit drydock.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2023 Resolved
"Fire extinguishers shall be subjected to maintenance at intervals of not more than 1 year, at the time of hydrostatic test, or when specifically indicated by an inspection or electronic notification." Vessel's fire extinguishers were last insp[ected on 31OCT2022, making them overdue for an inspection. Vessel is prior to passengers until fire extinguishers are properly serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2023
Resolution: Vessel had Sea Safety come service fire extinguishers on 06NOV2023. Deficency has been cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 November 2020 Resolved
Emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions mounted at or near the operating station. The emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in 46 CFR 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of the vessel.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2020
Resolved 2 December 2020
Resolution: Received satisfactory instructions.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.