ESPERANZA "HOPE" ANDRADE

ESPERANZA "HOPE" ANDRADE is a 2023 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2020, most recently in January 2026, along with 12 deficiencies and 1 casualty investigation in 2024.

Records from 2020 to 2026. Most recent: inspection, 7 January 2026.

Built
2023
Last inspected
7 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1086867
WDN3051
1609726
Flag
UNITED STATES
Maury page id
psix-1609726

Documentation record

Registered dimensions (L × B × D)280.0 ft × 66.0 ft × 16.0 ft
Registered tonnagegross 1,365 / net 1,111
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 1,522 / net 456
BuilderGULF ISLAND SHIPYARDS LLC · HOUMA, LA, UNITED STATES · built 2023
Hull materialSteel
PropulsionDiesel Electric
Hull shapeShip
Hull configurationMonohull
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1522 - Convention (Subpart B), Gross Ton
1365 - Regulatory (Subpart C or D), Gross Ton
456 - Convention (Subpart B), Net Ton
1111 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

7 January 2026 Examination of Repairs · Internal Structural Exam · Drydock Exam · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8291457
8 September 2025 Re-Inspection · MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8229803
5 September 2025 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8227664
12 June 2025 Re-Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8158827
15 April 2025 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8112257
3 April 2025 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8104838
6 March 2025 In-Service Inspection · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8089394
5 February 2025 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8074919
2 January 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8057258
3 November 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8028833
3 November 2024 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8032011
26 September 2024 COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7997660
23 May 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7923187
25 April 2024 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7901493
23 April 2024 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7900359
1 April 2024 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7888125
20 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7882314
25 January 2024 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7855560
25 September 2023 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7797811
21 June 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7720114
13 July 2020 Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7005601

Deficiency record · 12

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2025 Resolved
Each power bilge pump must have the capacity to develop a suction velocity of not less than 400 feet per minute through the size of bilge main piping required by § 56.50-50(d)(1) of this part under ordinary conditions. Vessel crew could not demonstrate proper operation of the main or emergency bilge pumps. Demonstrate operation the satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 October 2025
Resolved 24 September 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 September 2025 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. MI's observed oil soaked lagging on the "B" end generator nearest to the control booth. Renew all oil soaked lagging to satisfaction of USCG prior to operation of that engine.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 18 October 2025
Resolved 24 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 September 2025 Resolved
All valves and closing appliances, or other mechanisms which may be required to be operated for damage control purposes in case of emergency shall be conspicuously marked with letters at least 1 inch high identifying the control and the direction of operation. In all cases indication shall be provided to show whether the control is open or closed. The valves associated with the bilge system from the pump to the overboard discharge are not all marked or labeled as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2025
Resolved 1 October 2025
Resolution: Vessel rep submitted photos of temporarily labeled valves. Permanent labels are on order and will be installed upon arrival.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 April 2025 Resolved
The Material, design, construction, workmanship, and arrangement of main propulsion machinery and each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS steel vessel Rules (incorporated by reference, see 46 CFR 58.03-1), except as otherwise provided by this sub chapter, the A end experienced a failure resulting in a reduction in propulsion. Vessel is authorized to conduct sea trial with out passengers/cargo to determine the cause. enact repairs to the satisfaction of the classification society. Provide a Technician's report of cause of failure and statement detailing the events surrounding the casualty from the Master and Chief Engineer to [email withheld] 46CFR 58.05-1 def code 13108 action code 701a
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2025
Resolved 25 April 2025
Resolution: replaced blown fueses see attached reports
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 April 2025 Resolved
The Material, design, construction, workmanship, and arrangement of main propulsion machinery and each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS steel vessel Rules (incorporated by reference, see 46 CFR 58.03-1), except as otherwise provided by this sub chapter, the A end experienced a failure resulting in a reduction in propulsion. Vessel is authorized to conduct sea trial with out passengers/cargo to determine the cause. enact repairs to the satisfaction of the classification society. Provide a Technician's report of cause of failure and statement detailing the events surrounding the casualty from the Master and Chief Engineer to [email withheld] 46CFR 58.05-1 def code 13108 action code 701a
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2025
Resolved 4 April 2025
Resolution: conducted reboot of the system inspected for loose wires conducted a 3 hr sea trial. issue resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 November 2024 Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), except as otherwise provided by this subchapter.
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2024
Resolved 8 November 2024
Resolution: Marine Inspector [name withheld] GS-12 attented vessel to witness retro-fitted alarm strobes on all three chiller units with oeprational alarm test conducted. Vessel also posted signs and changed watch procedures to include rounds of chiller units. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2024 Resolved
Fixed fire extinguishing systems must be checked as noted in table 71.25-20(a)(2). MI's were provided with no evidence of any of the vessels NOVAC systems being tested within the last year as prescribed in the manufacturers instructions. Have system inspected and tested as per manufacturers instruction manual.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2024
Resolved 27 April 2024
Resolution: Annual inspection reports were provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 April 2024 Resolved
Each power bilge pump must have the capacity to develop a suction velocity of not less than 400 feet per minute through the size of bilge main piping required by § 56.50-50(d)(1) of this part under ordinary conditions. Vessel crew could not demonstrate proper operation of the main bilge pump. Demonstrate operation the satisfaction of attending class surveyor.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2024
Resolved 27 April 2024
Resolution: ABS provided a report attesting to the repair and witnessing of the bilge pump operating properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 September 2023 Resolved
Any vessel of atleast five net tons which engages in coastwise trade must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel does not have a Certificate of Documentation. Provide evidence that the Certificate of Documentation has been applied for and is being processed
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2023
Resolved 3 November 2023
Resolution: TXDOT submitted copy of valid COD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2023 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Electrical distribution panels are fitted with secondary door that is unlocked and allows access to live electrical components. Ensure that main secondary panel is locked while not being serviced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2023
Resolution: Electrical distribution panels observed to be properly secured.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2023 Resolved
Small rooms or spaces having a secondary means of escape which is not obviously apparent shall have a suitable sign in red letters “Emergency Exit” directing attention to escape. VOITH spaces A and B are fitted with an emergency escape that are not clearly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 2 November 2023
Resolution: Proper labeling observed to be in place for VOITH emergency exits.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2023 Resolved
Operator must crew vessel and familiarize them with safe operation. Local OCMI to witness required safety drills after TXDOT takes control of the vessel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2024
Resolution: Witnessed satisfactory fire fighting and man overboard drills

Casualty record · 1

3 November 2024Routine · role: Involved in a Marine Casualty · activity 8032011
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.