Inspections, by type

Years with a record 3 calendar years (2020–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it80860 - Dead Weight, Metric Ton
95136 - Displacement, Metric Ton
44403 - Convention (Subpart B), Gross Ton
27336 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

11 December 2025 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8281926
29 November 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7595511
12 April 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7429593
15 October 2020 PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7074907

Deficiency record · 4

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 December 2025 Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of the deficiencies noted in deficiency #2 below provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency. 74SOLAS(24) IX/3.1 ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2026
Resolved 20 February 2026
Resolution: Received satisfactory audit report from RO.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 11 December 2025 Resolved
Enclosed space entry and rescue drill should be planned and conducted in a safe manner, taking into account, as appropriate, the guidance provided in the recommendations developed by the organization. Vessel's safety management system requires a minimum of 03 personal multi-gas meters to be carried by personnel entered enclosed spaces. Vessel had zero personal multi-gas meters onboard. 74SOLAS(24) III/3.6.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2025
Resolution: Received class report attesting to multi-gas meters being supplied on board and tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 11 December 2025 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems. PSCO observed that when vessel's crew was questioned, the crew was unfamiliar with the vessel's CO2 time delay. 74SOLAS(24) II-2/15.2.2.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 12 December 2025
Resolution: Received class report attesting to crew training and familiarization being carried out.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 11 December 2025 Resolved
General arrangements plan shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions. PSCO observed posted fire control plan had incorrect door labeling for engine room to steering gear room.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 February 2026
Resolution: Received class report attesting to corrected deficiency.

Ownership record