← All vessels
CL DAYANG HE
CL DAYANG HE is a 2020 freight ship. The Coast Guard has recorded 4 inspections since 2020, most recently in December 2025, along with 4 deficiencies.
Records from 2020 to 2025. Most recent: inspection, 11 December 2025.
- Built
- 2020
- Last inspected
- 11 December 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9880283 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5TY8
1610501
Flag
LIBERIA
—
Maury page id
psix-1610501
Inspections, by type
The 4 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it80860 - Dead Weight, Metric Ton
95136 - Displacement, Metric Ton
44403 - Convention (Subpart B), Gross Ton
27336 - Convention (Subpart B), Net Ton
95136 - Displacement, Metric Ton
44403 - Convention (Subpart B), Gross Ton
27336 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 4
11 December 2025
PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8281926
29 November 2022
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7595511
12 April 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7429593
15 October 2020
PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7074907
Deficiency record · 4
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 December 2025
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of the deficiencies noted in deficiency #2 below provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency.
74SOLAS(24) IX/3.1
ISM Code 10.1
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 11 December 2025
Resolved
Enclosed space entry and rescue drill should be planned and conducted in a safe manner, taking into account, as appropriate, the guidance provided in the recommendations developed by the organization. Vessel's safety management system requires a minimum of 03 personal multi-gas meters to be carried by personnel entered enclosed spaces. Vessel had zero personal multi-gas meters onboard.
74SOLAS(24)
III/3.6.1
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 11 December 2025
Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems. PSCO observed that when vessel's crew was questioned, the crew was unfamiliar with the vessel's CO2 time delay.
74SOLAS(24)
II-2/15.2.2.1
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 11 December 2025
Resolved
General arrangements plan shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions. PSCO observed posted fire control plan had incorrect door labeling for engine room to steering gear room.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.