This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it66374 - Convention (Subpart B), Net Ton 146214 - Dead Weight, Metric Ton 190594 - Displacement, Metric Ton 145136 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
11 July 2023PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7728587
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 11 July 2023Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so desgined, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed active leak from steam pipe heating return line in purifier space.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 July 2023
Resolved 21 July 2023
Resolution: Received class report attesting to proper operation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 July 2023Resolved
The following functional requirements shall be met: (.2) means of control for flammable liquids in the space shall be provided. PSCO observed lube oil leak from gasket on number one generator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 July 2023
Resolved 11 July 2023
Resolution: Ship's engineers were able to change out the gasket and stop the leak while PSC examiners were still on board.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.