MAURY USCG vessel records
← All vessels

GARRINCHA

GARRINCHA is a 2019 tank ship. The Coast Guard has recorded 5 inspections since 2021, most recently in December 2025, along with 7 deficiencies.

Records from 2021 to 2025. Most recent: inspection, 11 December 2025.

Built
2019
Last inspected
11 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9547702
PY2021
1610806
Flag
BRAZIL
Maury page id
psix-1610806

Inspections, by type

Years with a record 4 calendar years (2021–2025)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it61426 - Regulatory (Subpart C or D), Gross Ton
114442 - Dead Weight, Ton
35855 - Regulatory (Subpart C or D), Net Ton
61426 - Convention (Subpart B), Gross Ton
35855 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

11 December 2025 COC-TVE Renew
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8276109
20 August 2024 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7985591
29 July 2024 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7956813
5 January 2023 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7612764
15 June 2021 COC-TVE Renew · PSC A
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7222201

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 July 2024 Resolved
The following fire protection system shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions. PSCO observed fire boundary insulation above ECR removed. 74SOLAS(20) II-2 14.2.1.1.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2024
Resolved 20 August 2024
Resolution: The subject insulation was repaired and considered satisfactory. It was confirmed that crew training for the structural fire protection was carried out on 8 Aug 2024.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 July 2024 Resolved
In tankers, electrical equipment shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO observed 01 cracked/ open light at the bottom of the pump room. 74SOLAS(20) II-1 45.11 10c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 29 July 2024
Resolved 29 July 2024
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 29 July 2024 Resolved
Oil tankers of 20,000 tons deadweight and above, constructed on or after 1 January 212, shall be provided with a fixed hydrocarbon gas detection system complying with the Fire Safety Systems Code for measuring hydrocarbon gas concentrations in all ballast tanks and void spaces adjacent to cargo tanks. PSCO observed the LEL sensor continuously reading 1% LEL in all ballast and void spaces and per the crew, it can only be calibrated shore side. 74SOLAS(20) II-2 4.5.7.3.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2024
Resolved 31 July 2024
Resolution: Received 3rd party report that the system was calibrated.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 29 July 2024 Resolved
Suitable portable instruments for measuring oxygen and flammable vapor concentrations in double-hull spaces and double-bottom spaces shall be provided. PSCO observed the vessel's portable detectors constantly reading 1% LEL and the vessel does not have the required equipment to calibrate. 74 SOLAS (20) II-2 4.5.7.2.1 16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2024
Resolved 31 July 2024
Resolution: Received 3rd party report that the system was calibrated.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 29 July 2024 Resolved
Any discharge into the sea of oil or oily mixtures from the cargo area of an oil tanker shall be prohibited except when the following conditions are satisfied: the tanker has in operation an oil discharge monitoring and control system. PSCO observed discharge rates exceeding the recorded rates in the ORB part II in the vessel's ODME logs. MARPOL ANNEX I / 34.6 16AC
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 12 August 2024
Resolved 20 August 2024
Resolution: The subject ODME, Modell: OILCON MARK 6M/VAF was recalibrated by Mackay marine and no abnormal condition was found. It was confirmed that crew training for the operation of ODME was carried out on 02 Aug 2024.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 29 July 2024 Resolved
The ORB Part II shall be completed on each occasion whenever any of the following cargo/ballast operations take place on the ship: discharge of water from slop tanks. PSCO observed recorded discharge rates differing from ODME logs as well as exceeding the vessel's pump's maximum operating capacity, specifically on March 8th, 9th, and April 18th. MARPOL ANNEX I / 36.2.7 10C
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 July 2024
Resolved 29 July 2024
Resolution: Error in ORB acknowledged.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 29 July 2024 Resolved
The company should ensure that all personnel involved in the company's SMS have an adequate understanding of the relevant rules, regulations, codes, and guidelines.[6.4] the technical nature of the deficiencies listed above provide objective evidence of a serious failure of the implementation of the ISM Code, and an internal audit of the vessel's SMS focusing on ODME discharges, confined space entry, and portable and fixed gas detection maintenance is required. 74 SOLAS (20) IX/3.1 ISM CODE 6.4 16AC
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2024
Resolved 20 August 2024
Resolution: Owner reported that additional audit was carried out on 04 Aug 2024 and the subsequent dates. Per the audit report, the audit was focusing on the deficiencies listed in the USCG Form B dated 29 July 2024 and the vessel's SMS and no further non-conformity

Ownership record