ATLANTIC PRINCE

ATLANTIC PRINCE is a tank ship. The Coast Guard has recorded 4 inspections since 2020, most recently in July 2024, along with 3 deficiencies.

Records from 2020 to 2024. Most recent: inspection, 3 July 2024.

Built
Not recorded
Last inspected
3 July 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9874662
V7A2789
1610820
Flag
MARSHALL ISLANDS
Maury page id
psix-1610820

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 3 calendar years (2020–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it13876 - Convention (Subpart B), Net Ton
50000 - Dead Weight, Metric Ton
55483 - Displacement, Metric Ton
29356 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

3 July 2024 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7948431
21 June 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7939087
28 February 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7403074
10 June 2020 COC-TVE Annual · PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6970300

Deficiency record · 3

10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 21 June 2024 Resolved
THE VOYAGE DATA RECORDER SYSTEM, INCLUDING ALL SENSORS, SHALL BE SUBJECTED TO AN ANNUAL PERFORMANCE TEST. THE TESTS SHALL BE CONDUCTED BY AN APPORVED TESTING OR SERVICING FACILITY TO VERIFY THE ACCURACY, DURATION AND RECOVERABILITY OF THE RECORDED DATA. A COPY OF THE CERTIFICATE OF COMPLIANCE ISSUED BY THE APPLICABLE PERFORMANCE STANDARDS, SHALL BE RETAINED ON BOAR DHTE HSIP. VDR BATTERY PACK EXPIRED AND CERTIFICATE OF COMPLIANCE ISSUED IS EXPIRED. 74 SOLAS(20)v/18.8 40AC
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2024
Resolved 3 July 2024
Resolution: PSCO received survey report that states: Completed, VDR backup battery replacement with satisfactory. Configred, new battery backup expiry date to read 01 Apr 2028. FURUNO/VR-7000 VDR IS OPERATIONAL. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 June 2024 Resolved
WHERE "A" CLASS DIVISION ARE PENETRATED, SUCH PENETRATIONS SHALL BE TESTED IN ACCORDANCE WITH THE FIRE TEST PROCEDURES. SUCH PENETRATIONS SHALL BE SUITABLY INSULATED BY EXTENSION OF THE INSULATION AT THE SAME LEVEL OF THE DIVISION. PSCO OBSERVED MISSING INSULATION ON ELECTRIC PANEL IN THE CO2 ROOM. 74 SOLAS(20 CONS.) II-2/9.3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 June 2024
Resolved 21 June 2024
Resolution: Crew quickly replaced the missing insulation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 June 2024 Resolved
THE GAS DETECTION EQUIPMENT SHALL BE DESIGNED TO SAMPLE AND ANALYSE FROM EACH SAMPLING LINE OF EACH PROTECTED SPACE, SEQUENTIALLY AT INTREVALS NOT EXCEEDING 30 MIN. PSCO OBSERVED EMPTY BALLAST TANKS GAS DETECTION TO BE DISCONNECTED. 74 SOLAS(20 CONS.)II-2/7.2.2 FSS CODE 16.2.2.3.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2024
Resolved 21 June 2024
Resolution: Chief officer turned the gas sampling back on for the ballast tanks.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.