← All vessels
ATLANTIC PRINCE
ATLANTIC PRINCE is a tank ship. The Coast Guard has recorded 4 inspections since 2020, most recently in July 2024, along with 3 deficiencies.
Records from 2020 to 2024. Most recent: inspection, 3 July 2024.
- Built
- Not recorded
- Last inspected
- 3 July 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9874662 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A2789
1610820
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1610820
Inspections, by type
Years with a record
3 calendar years (2020–2024)
The 4 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it13876 - Convention (Subpart B), Net Ton
50000 - Dead Weight, Metric Ton
55483 - Displacement, Metric Ton
29356 - Convention (Subpart B), Gross Ton
50000 - Dead Weight, Metric Ton
55483 - Displacement, Metric Ton
29356 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 4
3 July 2024
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7948431
21 June 2024
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7939087
28 February 2022
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7403074
10 June 2020
COC-TVE Annual · PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6970300
Deficiency record · 3
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 21 June 2024
Resolved
THE VOYAGE DATA RECORDER SYSTEM, INCLUDING ALL SENSORS, SHALL BE SUBJECTED TO AN ANNUAL PERFORMANCE TEST. THE TESTS SHALL BE CONDUCTED BY AN APPORVED TESTING OR SERVICING FACILITY TO VERIFY THE ACCURACY, DURATION AND RECOVERABILITY OF THE RECORDED DATA. A COPY OF THE CERTIFICATE OF COMPLIANCE ISSUED BY THE APPLICABLE PERFORMANCE STANDARDS, SHALL BE RETAINED ON BOAR DHTE HSIP. VDR BATTERY PACK EXPIRED AND CERTIFICATE OF COMPLIANCE ISSUED IS EXPIRED. 74 SOLAS(20)v/18.8 40AC
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 June 2024
Resolved
WHERE "A" CLASS DIVISION ARE PENETRATED, SUCH PENETRATIONS SHALL BE TESTED IN ACCORDANCE WITH THE FIRE TEST PROCEDURES. SUCH PENETRATIONS SHALL BE SUITABLY INSULATED BY EXTENSION OF THE INSULATION AT THE SAME LEVEL OF THE DIVISION. PSCO OBSERVED MISSING INSULATION ON ELECTRIC PANEL IN THE CO2 ROOM. 74 SOLAS(20 CONS.) II-2/9.3.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 June 2024
Resolved
THE GAS DETECTION EQUIPMENT SHALL BE DESIGNED TO SAMPLE AND ANALYSE FROM EACH SAMPLING LINE OF EACH PROTECTED SPACE, SEQUENTIALLY AT INTREVALS NOT EXCEEDING 30 MIN. PSCO OBSERVED EMPTY BALLAST TANKS GAS DETECTION TO BE DISCONNECTED. 74 SOLAS(20 CONS.)II-2/7.2.2 FSS CODE 16.2.2.3.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.