MAURY USCG vessel records
← All vessels

ULTRA OCELOT

ULTRA OCELOT is a 2020 freight ship. The Coast Guard has recorded 7 inspections since 2020, most recently in February 2026, along with 2 deficiencies and 2 operational controls.

Records from 2020 to 2026. Most recent: inspection, 3 February 2026.

Built
2020
Last inspected
3 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 February 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9871191
9V2607
1610829
Flag
SINGAPORE
Maury page id
psix-1610829

Documentation record

Tonnage as PSIX records it41241 - Convention (Subpart B), Net Ton
81901 - Dead Weight, Metric Ton
95462 - Displacement, Metric Ton
45432 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

3 February 2026 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8305570
14 October 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8253355
21 August 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8205997
20 November 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7827515
1 September 2023 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7777042
26 August 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7777092
4 June 2020 PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6963967

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 August 2025 Resolved
A fixed fire detection and fire alarm system and a sample extraction smoke detection system required in this regualtion and other regulations in this part shall be of an approved type and comply with the fire safety systems code. Any required system shall be capable of continuous operation at all times... PSCO observed a fault displayed on the smoke extraction system panel. The chief engineer explained that the system was not operational due to water damage. The display screen read Fault: detector -01 -02 -03 -04 -05 -06 74 SOLAS (2020) II-2/7.2.2 FSS Code 10/2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2025
Resolution: Smoke detectors are only required while carrying dangerous goods. Vessel is currently only carrying corn. Ship will receive spare parts to make permanent repairs in Japan.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 August 2025 Resolved
Fire doors in... stairway enclosures... shall satisfy the following requirements: The doors shall be self-closing PSCO observed the main stairway doors on A and B decks not closing and latching. 74 SOLAS (2020) II-2/9.4.1.1.5.1
Action required: 10 - Deficiency Rectified
Resolved 21 August 2025
Resolution: Corrected on the spot

Ownership record