Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it38026 - Dead Weight, Metric Ton 46314 - Displacement, Metric Ton 12101 - Convention (Subpart B), Net Ton 23232 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
14 October 2025Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8249431
7 October 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8249056
5 October 2025PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8242069
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 5 October 2025Resolved
FIRE PROTETION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. PSCO OBSERVED A RUST SPOT AND ACTIVE LEAKING IN PIPELINE WHILE EMERGENCY FIRE PUMP WAS RUNNING LEAKING SECTION OF THE PIPE LINE WAS UNABLE TO BE MECHANICALLY ISOLATED FROM THE EMERGENCY FIREMAIN.
SOLAS 74 am II-2/14.1 17ac
SOLAS (2014) II-2/14.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2025
Resolved 7 October 2025
Resolution: Received, reviewed and accepted Class report from NKK attesting to the permanent repair to the emergency fire line.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.