MAURY USCG vessel records Sign in
← All vessels

MTM KEY WEST

MTM KEY WEST is a 2020 tank ship. The Coast Guard has recorded 4 inspections since 2023, most recently in April 2026, along with 1 deficiency.

Records from 2023 to 2026. Most recent: inspection, 21 April 2026.

Built
2020
Last inspected
21 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9790672 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V6013
1611353
Flag
SINGAPORE
—
Maury page id
psix-1611353

Inspections, by type

Years with a record 4 calendar years (2023–2026)
The 4 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it21242 - Convention (Subpart B), Gross Ton
35894 - Dead Weight, Metric Ton
44861 - Displacement, Metric Ton
10288 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 4

21 April 2026 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8353278
21 April 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8111798
21 March 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7881028
17 January 2023 PSC A · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7618821

Deficiency record · 1

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 April 2026 Resolved
The venting system shall be provided with devices to prevent the passage of flame into the cargo tanks. PSCO Observed that the flame screens on the PV Valves 8S and 7P were excessively corroded. SOLAS (20) II-2/4.5.3.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2026
Resolution: Crew satisfactorily replaced the flame screens in the presence of PSCO.