EMPIRE STATE is a 2023 school ship. The Coast Guard has recorded 19 inspections since 2020, most recently in June 2026, along with 75 deficiencies — 3 with no resolution recorded —.

Records from 2020 to 2026. Most recent: inspection, 26 June 2026.

Built
2023
Last inspected
26 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 June 2026
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9910313
WDO2002
1611813
Flag
UNITED STATES
Maury page id
psix-1611813

Documentation record

Registered dimensions (L × B × D)505.3 ft × 88.6 ft × 36.5 ft
Registered tonnagegross 25,985 / net 7,795
ITC dimensions (L × B × D)505.3 ft × 88.6 ft × 36.5 ft
ITC tonnagegross 25,985 / net 7,795
BuilderPHILLY SHIPYARD INC · Philadelphia, PA, UNITED STATES · built 2023
Hull materialSteel
PropulsionDiesel Electric
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25985 - Convention (Subpart B), Gross Ton
7795 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

26 June 2026 Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8418450
25 June 2026 Administrative Inspection · Deficiency Check · Vessel Attendance
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8418437
3 November 2025 COI Inspection · Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8262271
27 October 2025 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8259092
29 September 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8243206
18 August 2025 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8212781
23 July 2025 Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8192572
10 February 2025 Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8077509
10 February 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8098599
19 December 2024 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8049494
14 August 2024 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7984600
30 July 2024 Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7970537
5 July 2024 In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7953841
27 June 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7944241
7 February 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7861329
25 January 2024 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7855674
17 January 2024 Administrative Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7850260
24 October 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7813456
1 May 2020 Initial Certification · Construction Oversight · MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7032830

Deficiency record · 75

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2025 Resolved
A safety system shall be provided to ensure that serious malfunction in machinery or boiler operations, which presents and immediate danger , shall initiate an automatic shutdown of the plant and that an alarm shall be given. During the fuel leak-off test on the #3 MDE the fuel oil sensor failed to activate during the test in the seated position. Vessel to repair the fuel oil sensor and test to the satisfaction of the OEM (Cummins servicing technician) and submit the technician's report attesting to proper repairs/operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2025
Resolution: Received Cummins - PTSP REPORT EMPIRE STATE- Nov - Dec 2025 attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 November 2025 Resolved
Fire-extinguishing appliances shall be readily available. The system may be; A fixed gas fire extinguishing system complying with the code. During the 6-month interval testing the pressure test of the cylinders revealed (02) inergen bottles that revealed a severe pressure drop due to leak-off. Servicing company to provide service report attesting to the total number of cylinders failed; attest to renewal of the cylinders that failed during pressure testing and a causal analysis of the cylinder heads attached to the failed cylinders along with a summary of findings from the manufacturer and recommended preventative measures.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2025
Resolution: Reviewed and accepted technician's report attesting to renewal of the (02) empty cylinders identified during the 6-month servicing.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 March 2025 Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and life raft embarkation deck. The Deck Officer’s offices are considered to be a “room-in-room” arrangement and are not provided with direct access to an acceptable means of escape. An equivalent level of safety should be provided for escape purposes. Specifically, in lieu of an acceptable means of escape, we will accept an arrangement where crew in these areas are given immediate and clear notification of a fire in the surrounding space. 74 SOLAS (20 Amended) Ch. II-2 Reg. 13.1.1 MSC PRG SOLAS-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2025
Resolved 24 April 2025
Resolution: Doors have been fixed with signage reading “Door to remain open when office is occupied.”
09 - Working and Living Conditions › 091 - Living Conditions › Other (food)
Issued 24 March 2025 Resolved
In a visible location in each washing space, and in each crew berthing area, the owner or operator of a vessel must display information regarding procedures and resources to report crimes that occur upon the vessel, including sexual assault and sexual harassment, and vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage. Provide the proper signs per Policy Letter 23-04 “Guidance on Statutory Information Requirements Within Accommodation Spaces on Merchant Vessels” Title 46, United States Code (U.S.C.) § 11101
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2025
Resolved 28 April 2025
Resolution: Crew reports having installed signage. Spot checked, all sat.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 March 2025 Resolved
Within the perimeter of stairway enclosures, only public toilets, lockers of noncombustible material providing storage for non-hazardous safety equipment and open information counters are permitted. MARAD to propose a remedy for the door that led to the elevator electrical space in the aft stairway 02 deck, approximately frame 75/80 74 SOLAS (20 Amended) Ch. II-2 Reg. 13.3.2.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2025
Resolved 25 March 2025
Resolution: Fire Control Plan designates the door in question as an A-0 door within the staircase encllosure.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 March 2025 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photo-luminescent strip indicators in many of the spaces there are photo-luminescent signs that are not being charged because the lights are out. Prove that the photo-luminescent exit signs can provide at least 15 mcdlm measured 10 min after the removal of all external illumination sources. The system should continue to provide luminance values greater than 2 mcd/m 2 for 60 min. 74 SOLAS (20 Amended) Ch. II-2 Reg. 13.3.2.5.1 IMO Resolution A.752(18)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2025
Resolved 25 March 2025
Resolution: Functional test was completed with lights on in mass berthing spaces. Emergency escape signs verified to properly function with adequate charge.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 24 March 2025 Resolved
There was no training manuals laid out for the crew. A training manual complying with the requirements shall be provided in each crew mess room and recreation room or in each crew cabin Provide a training manual in each crew mess and recreational room. 74 SOLAS (20 Amended) Ch. III Reg. 35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 25 March 2025
Resolution: Training manuals now provided in the break rooms and recreational areas for the cadets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2025 Resolved
The purpose of this regulation is to suppress and swiftly extinguish a fire in the space of origin...the following functional requirements shall be met: fire-extinguishing appliances shall be readily available. During testing of the aft deck foam applicator system a breach in the fire main in the flange connection(s) iwo fire station #130 on deck three & flange connection on deck two were discovered. Observed both flange connection breaches allowing water to free-flow from the faulty gaskets in both locations compromising the systems pressure and creating a safety hazard impacting personnel and means of egress to port side lifeboats. The following requirements shall be met: 1.) Identify the cause of the breach in both flange connections on the fire main. Make repairs to original. 2.) Ensure an adequate pressure test is witnessed in the presence of a Coast Guard Marine Inspector. 74 SOLAS (2020) II-2 / 10.1.1.2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2025
Resolution: Fire Main repair is completed and pressure test witnessed by the attending MI.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 February 2025 Resolved
The purpose of this regulation is to suppress and swiftly extinguish a fire in the space of origin...the following functional requirements shall be met: fire-extinguishing appliances shall be readily available. During testing of the aft deck foam applicator system a breach in the fire main in the flange connection(s) iwo fire station #130 on deck three & flange connection on deck two were discovered. Observed both flange connection breaches allowing water to free-flow from the faulty gaskets in both locations compromising the systems pressure and creating a safety hazard impacting personnel and means of egress to port side lifeboats. The following requirements shall be met: 1.) Identify the cause of the breach in both flange connections on the fire main. Make repairs to original. 2.) Ensure an adequate pressure test is witnessed in the presence of a Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2025
Resolution: Observed satisfactory pressure test. System held pressure for 10 minutes and no visible leaks were discovered in the system. Repairs were deemed acceptable at the time of inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2025 Resolved
A fixed fire-extinguishing system required by...may be a fixed pressure water-spraying fire extinguishing system complying with the provisions of the FSS Code. During annual testing, automatic activation per the systems operations manual failed to activate the pump after the activation of both (02) detectors (flame & smoke) in 2 locations in the following machinery spaces: Incinerator Space and ER3. Provide the following: 1.) Servicing technicians report documenting the condition discovered during testing, the RCA root cause analysis and any corrective action carried out. 2.) Crew shall demonstrate automatic activation of the system (activation of 2 detector heads in the effected space) in all respective spaces covered by the Fain system in the presence of an attending Marine Inspector. 74 SOLAS 2020 II-2/4.1.1.3 FSS CODE
Action required: 705 - Other - as specified
Resolved 18 March 2025
Resolution: Witnessed satisfatory test of the #1 Fire Pump pressure differential adjusted to start at 6.5 BAR and cut-out at 8.5 BAR.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 February 2025 Resolved
During annual testing of the Fixed Firefighting System (Inergen) the Inergen space/control space filled with Inergen, causing the room to become oxygen deficient (15-19.5%) thus creating a dangerous situation for personnel. Provide root cause analysis of this issue. Additionally the system has been rebuilt due to debris in lines and miscellaneous parts, the vessel must prove the system is back together as per the approved plans and conduct approved pressure testing on effected system and piping in the presence of a Coast Guard Marine Inspector. No further testing will be conducted until all parties are satisfied with results of the RCA and proper system verification has been conducted as described above.
Action required: 705 - Other - as specified
Resolved 27 February 2025
Resolution: System is intalled correctly, safety concern remains.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 February 2025 Resolved
Fire protection systems and firefighting systems and appliances shall be maintained and ready for use, fire protection systems, firefighting systems and appliances shall be properly tested and inspected. During annual testing of the installed fixed firefighting system (Inergen), a safety relief valve discharged Inergen into the control space. Due to the uncertainty of the system to properly operate as designed, no internal combustion equipment may be operated in the following spaces— Zone 1: Engine Room 1, Control Room 1, & HV Room Zone 2: Engine Room 2, Control Room 2, & HV Room 2. Zone 3: Motor Room 1 & Frequency Converter Room 1. Zone 4: Motor Room 2 & Frequency Converter Room 2. Zone 6: Incinerator Room. Emergency Diesel Generator may be only used in case of an emergency.
Action required: 705 - Other - as specified
Resolved 27 February 2025
Resolution: System correctly installed. Reports received by Ansul and Tote.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 January 2025 Resolved
No fire detection is provided in the Reefer Provisions Storage 1 and 2 on the 2nd Deck. SOLAS II-2/7.5.2 requires fire detection and alarm system in service spaces, control stations and accommodation spaces. Per the fire risk categorization labels under SOLAS II-2/9.2.2.3.2, refrigerated chambers fall under category (11) ("auxiliary machinery spaces, cargo spaces, cargo and other oil tanks and other similar spaces of moderate fire risk"). As these two spaces were correctly categorized as category (11), rather than category (13) ("store-rooms, workshops, pantries, etc."), SOLAS II-2/9.2.2.3.2 was not applied. However, USCG MSC PRG SOLAS-37 requires fire detection and suppression to be installed within category (11) refrigerated storage spaces.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2025
Resolution: Reefer Heat Detectors (13) are installed and operating properly. Detector specifications provided with servicing technician's report.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 November 2024 Resolved
During a recent blackout of the ship, there was an area that was totally blacked out during the transitional power. Demonstrate at nighttime that the vessels transitional power lighting in all service and accommodation alleyways, stairways and exits is adequate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2025
Resolution: Emergency Lighting walk-through of the vessel is completed. Two small vestibule areas were missed in construction in narrative. The deficiency is cleared based on the complete evaluation of the emergency lighting system on all 4 load centers.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 4 November 2024 Resolved
General alarm bells shall be marked in not less than 1/2-inch red letters: ‘‘General Alarm — When Bell Rings Go to Your Station". Mark all general alarm indicators (visual/audible).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2025
Resolution: Cleared to the satisfaction of the attending MI
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 November 2024 No resolution recorded
During plan review of Patriot State, it was found that the aft mooring deck (SFP Plan NSMV-635-B801, Rev.6, Sheet 23 of 34) is shown as a Category 5 open deck space. For this categorization to be correct it must be at least 30% open to the outside of the ship and the overhang must be no more than 10m.Based on the 25% opening, the aft mooring deck is an enclosed space and is to be protected by a manual or automatic deluge system. Provide a plan to come into compliance to the satisfaction of the local OCMI. Prior to sailing, provide a satisfactory risk mitigation plan subject to approval of the cognizant OCMI.
Action required: 705 - Other - as specified
Due 30 September 2028
Resolution: Rectify at next out-of-water drydocking.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 November 2024 Resolved
It was reported that the fire pump doesn’t start up automatically. Demonstrate that at least one effective jet of water is immediately available from any hydrant by the automatic starting of one required fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2025
Resolution: Witnessed proper auto start of the #1 Fire Pump at 6.5 Bar. Kongsberg servicing report attached to this activity. Adjusted pressure differential presssure setting to shutdown at 8.5 bar.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 November 2024 Resolved
Prove that if the ship is under unfavorable conditions of trim of up to 10° and listed up to 20° either way that there will be no damage to the lifeboats if the following occur; (a) Damage to the hull of lifeboats by striking the embarkation ladder handrails (b) damage to the forward and aft ends of the boats from striking the gripe
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2025
Resolution: MARAD rep provided documents showing that, IAW SOLAS, launching of the lifeboats in unfavorable conditions was considered during Plan Review.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 November 2024 Resolved
Hydrants shall be so placed that the fire hoses may be easily coupled to them. It was found that fire stations #13 #66 appear to be installed in a position that could cause the hoses to kink, in addition some of the stations are not hooked up, in interior locations fire hoses shall be always connected to the hydrants. Demonstrate to the attending USCG that the hoses can be easily charged with out kinking and can easily be changed out if needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2025
Resolution: Deficiency resolved. ABS witnessed pressure test of the hoses in question and verified adequate pressure was provided at the nozzle.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 November 2024 No resolution recorded
11/4/24 - MISLE #7984600: A request for equivalency was submitted by ABS Global Engineering to USCG MSC for "MINIMUM CLEAR DOOR WIDTHS IN ESCAPE PATHS" and "MEANS OF QUICK RELEASE FROM PUBLIC SPACES" (ABS Work Order WO0004882-G). The request was denied by USCG MSC, as there was insufficient justification (MSC Ltr H2-2403559). While the request for exemption pends, provide a satisfactory risk mitigation plan subject to approval of the cognizant OCMI.
Action required: 705 - Other - as specified
Due 30 September 2028
Resolution: CLEAR DOOR WIDTHS IN ESCAPE ROUTES exemption received. MEANS OF QUICK RELEASE FROM PUBLIC SPACES still valid and requires rectification at next out-of-water drydocking.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 October 2024 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained and ready for use, fire protection systems, fire-fighting systems and appliances shall be properly tested and inspected. During annual testing of the installed fixed firefight system (INERGEN) the selector valve failed to open. Due to the uncertainty of the systems to properly operate as designed, no internal combustion equipment may be operated in the following spaces— Zone 1: Engine Room 1, Control Room 1, & HV Room Zone 2: Engine Room 2, Control Room 2, & HV Room 2. Zone 3: Motor Room 1 & Frequency Converter Room 1. Zone 4: Motor Room 2 & Frequency Converter Room 2. Zone 6: Incinerator Room. Emergency Generator may be only used in case of an emergency
Action required: 705 - Other - as specified
Resolved 30 January 2025
Resolution: Witnessed satisfactory manual testing of INERGEN system.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 August 2024 Resolved
Fire protection systems and fire fighting systems and applicances shall be maintained and ready for use. Fire protection systems, fire fighting systems and appliances shall be properly tested and inspected. During annual testing of the installed fixed firefighting system (INERGEN) the selector valve failed to open. Due to the uncertainty of the system to work properly operate as designed, no internal combustion equipment may be operated in the following spaces Zone 1: Engine Room 1, Control Room 1 & HV Room 1. Zone 2: Engine Room 2, Control Room 2 & HV Room 2. Zone 3: Motor Room 1 & Frequency Converter Room 1. Zone 4: Motor Room 2 & Frequency Converter Room 2. Zone 6: Incinerator Room. Emergency Generator may be used only in case of emergency.
Action required: 705 - Other - as specified
Due 15 March 2025
Resolved 30 January 2025
Resolution: Attended vessel to complete final walk-through of manual release procedures for the inergen system. Annual testing still pending completion. This condition has been lifted.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 June 2024 Resolved
Periodic Safety Test Procedures (PSTP) must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Systems addressed must include fire detection and extinguishing, flooding safety, propulsion, maneuvering, electric power generation and distribution, and emergency internal communications. Prior to next annual inspection, provide objective evidence that all the PSTPs under document number NSMV-095-DT901 “Periodic Safety Test Procedures” were accomplished by a person designated by the owner of the vessel and witnessed to the satisfaction of a US Coast Guard Marine Inspector.”
Action required: 705 - Other - as specified
Due 8 September 2024
Resolved 19 May 2025
Resolution: Prior to next annual inspcetion.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 June 2024 No resolution recorded
Periodic Safety Test Procedure (PSTP) documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm setpoints, the procedure to be followed, and the expected test result. PSTPs were found to not reflect actual conditions aboard vessel nor accurately describe actual steps required to conduct the applicable tests. PSTPs are to be reviewed, updated as necessary, and submitted for approval to the vessels Recognized Organization (RO) and USCG prior to the next annual inspection to the satisfaction of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 25 March 2026 — due date passed with no resolution recorded
Resolution: Awaiting return from RO and MSC.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 June 2024 Resolved
During the demonstrated of the rescue boat in the water the boat was not able to be started. It appeared that the batteries were not fully charged. Before the ship leaves port and always during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Demonstrate the proper starting and operation of the rescue boat in the water prior to sailing to the satisfaction of the US Coast Guard, in addition determine the cause of the failure.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2024
Resolution: Received conformation along with pictures that the rescue boat operated in the water, batteries were just old
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2024 Resolved
The machinery, piping systems and fittings shall be adequate for the service for which they are intended. It was discovered that the fuel service systems in the Nr 1 Engine Room for Nr 1 MDG and Nr 2 MDG were contaminated with water from an unidentified source. Troubleshoot and repair/rectify to the satisfaction of a USCG Marine Inspector prior to vessel departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2024
Resolution: The fuel for the Service and Settler tanks in ER 1 has been filtered. DG 1 and DG 2 have been run off the Service tank with no issues observed. Purifiers 1 and 2 in ER 1 have been checked and are operating as designed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 May 2024 Resolved
The function of fixed fire detection and alarm systems shall be periodically tested by method established in the manufacturers recommended testing procedures. Crew provide evidence of testing of all and be able to demonstrate the same via testing of all heat/smoke/flame detectors and call points to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 May 2024 Resolved
Dampers shall have direct mechanical means of release, or, alternatively, be closed by electrical, hydraulic, or pneumatic operation. During PSTP 5.07.02 damper closed but failed to indicate in ECC. Associated vent fan continued to run against the closed damper. Further, multiple damper visual indications are displaying improper signals throughout the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 May 2024 Resolved
Means of Control shall be provided for stopping ventilating fans. During the PSTP 4.01.08 & 4.01.09 remote stops on WH (bridge) & TB for ventilation fans failed shutdown fans as required. Crew to ensure proper operation of all remote stops for ventil
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 May 2024 Resolved
Machinery shall be adequate for the service for which it is intended. During PSTP 1.12.05 observed seal failure on MGE 1 during the fuel pressure bleed off test spilling fuel oil into the engine room. Renew and submit report from Cummmins rep attesting to proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 May 2024 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. During a deck walk of the helo-deck the electric motor casing powering the port side aft capstan was found cracked. Replace as appropriate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
Resolution: Motor has been tagged out and a warranty claim has been submitted
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 May 2024 Resolved
Demonstrate operation of self-closing door upper deck to engine room casing #2. Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs including fire-resisting divisions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 May 2024 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs Battery room upper deck starboard side fixed fire fighting system nozzle covered by orange cap.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 May 2024 Resolved
Galleys are spaces with installed cooking appliances with surfaces that may exceed 121° C (250° F). Off the the multipurpose room there is a "Pantry" with heating surface that exceeds 121° C (250° F). Drawing NSMV-635-B801 Sheet 20-1 of 31 shows the space as a "Cat-13". With the type of equipment the space should be a "Cat-12". Have nav architects reexamine the space to ensure that the space has the proper structural fire protection around the space and re-class the space. ***STOVE TOP IS TAGGED OUT***
Action required: 705 - Other - as specified
Due 30 September 2024
Resolved 3 June 2024
Resolution: Cook top has been tagged out
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 May 2024 Resolved
Maintenance, testing and inspections shall be carried out based on manufacturer’s maintenance and inspection guidelines. Prior to sailing the vessel is to have an approved serving company conduct the 6-month servicing as per the Maintenance Manual page 10-1 (verify that INERGEN cylinders are at the proper pressure)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
Resolution: Service report received
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 May 2024 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. Prior to movement the crew is to demonstrate proficiency in the operation of the INERGEN system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
Resolution: Harris Firefighting gave training to Master, Chief Engineer and serval crewmembers
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 1 May 2024 Resolved
After looking at Lifeboat #2 Serial #20/2/7893 and discussing the issue of whether the fuel oil has leaked into the fiberglass, in addition not knowing the amount of fuel that has come from the fuel tank along with observing oil still leaking from the underside of the boat and due to the uncertainty of the condition of the hull, it has been decided that Lifeboat #2 in its present condition is not usable and will need to be removed from the ship. **Before Lifeboat #2 is removed from the vessel provide a plan for remove of the lifeboat due to the possibility of pollution from oil
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 April 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The vessel has self-reported that they had discovered fuel leaking outside boat plug strainer of lifeboat #2, and there appears to be an old epoxy repair of the molded structure beneath the fuel tank foundation at the joint. The boat needs to be taken out of service/possibly condemned as fuel could have leaked into the fiberglass sandwich. Replace the lifeboat prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2024
Resolution: Repairs made
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The vessel has self-reported that they have discovered cracking/delaminating around the exterior of the hatch (iwo of coxswain seat) of lifeboat #3. Make repairs using a qualified company, authorized by the manufacture of the lifeboat. Make repairs prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2024
Resolution: Repirs made only gelcoat crack
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The vessel has self-reported that they are not able to start the #5 lifeboat. The lifeboat engine is to be serviced by a qualified company, authorized by the manufacture of the lifeboat. Prior to sailing, demonstrate proper operation of the lifeboat in the water to the USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2024
Resolution: Bad stater
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The vessel has self-reported that they are not able to release the fast rescue boat when water borne. Possible cause could be the interlock does not unlock release handle. In addition, the indication lights do not appear to properly identify if the boat is water borne. Make repairs using a qualified company, authorized by the manufacture of the rescue boat. Prior to sailing, demonstrate proper operation of the fast rescue boat in the water to the USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 25 April 2024 Resolved
Ships shall be provided with means of embarkation on and disembarkation from ships for use in port and in port related operations, such as gangways shall meet the guidelines set out in MSC.1/Circ.1331. The ships gangway has a stanchion (wire support) on the inside of the gangway which reduces the clearance. Ensure that the clearance is no less than the standard set outlined in ISO 5488:1979. To the satisfaction of the attending USCG Marine Inspector. With in 2 weeks
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2024
Resolution: Post removed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2024 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The crew during monthly fire extinguishers checks have found that there are over 100 extinguishers which are either under or overweight. With in 2 weeks have an authorized serves company service all portable fire extinguishers to ensure that they are all in proper working condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2024
Resolution: Received copy of Sea Safety Report
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 March 2024 Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Systems addressed must include fire detection and extinguishing, flooding safety, propulsion, maneuvering, electric power generation and distribution, and emergency internal communications. Prior to sailing, provide proof that all the PSTSP under document number NSMV-095-DT901 “Periodic Safety Test Procedures” were witness by the US Coast Guard. If not, then person designated by the owner of the vessel shall conduct all Periodic Safety Tests which shall be witnessed to the satisfaction of a US Coast Guard Marine Inspector
Action required: 705 - Other - as specified
Resolved 3 June 2024
Resolution: Periodic Safety Test Procedures were commenced in the presence of the marine inspectors, but not fully completed. An adequate number of tests were conducted to provide reasonable assurance of the fuctionality and safe operation of the systems.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2024 Resolved
Each crew berthing and washing spaces must be equipped with information in a visible location regarding the information as listed in USCG Policy Letter 23-04, “Guidance of Statutory Information Requirements Within Accommodation Spaces on Merchant Vessels”. Vessel did not have CG reporting phone number on displayed signage in the crew berthing areas. Prior to sailing provide the proper signage in all berthing spaces and washing spaces.
Action required: 705 - Other - as specified
Resolved 3 June 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2024 Resolved
Video/audio surveillance equipment must be placed in passageways in which doors from staterooms open. Such equipment must be placed in a location/position, or multiple locations/positions, that can continually view every door in each passageway. The ships installed Closed-Circuit Television (CCTV) system is not able to cover all cabins. As per USCG Policy Letter 23-05 “Guidance on Surveillance Requirements for Certain Commercial Vessels that Do Not Carry Passengers”, at the next scheduled dry-dock but no later than 08 September 2026, video and audio surveillance equipment must be placed in passageways into which doors from staterooms open, and such equipment must be placed in a locations and positions that can continually view every door.
Action required: 705 - Other - as specified
Due 8 September 2026
Resolved 3 June 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2024 Resolved
Vessels must be equipped with a master key control system for physical, manual, or electronic keys or access systems, which provides controlled access to all copies of the vessel’s master key. In addition, only crew-members identified by position in the master key control system are allowed access and use of a master key. The list of crew-members with master key access must be kept on the vessel. The list must also be maintained within the vessel owner’s records and documented in the vessel’s Safety Management System (SMS). Prior to sailing, demonstrate that doors that have keys and Radio Frequency Identification (RFID) locks can lock. In addition, provide to the USCG for review the documents, logs, and records necessary to ensure compliance with key control requirements as provide in U.S Coast Guard Policy Letter 23-06 “Guidance on Master [name withheld] on Merchant Vessels.
Action required: 705 - Other - as specified
Resolved 3 June 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Noise, vibration and other ambient factors
Issued 1 March 2024 Resolved
Ships shall be constructed to reduce onboard noise and to protect personnel from the noise in accordance with the “Code on Noise Levels on Board Ships”, resolution MSC.337(91), hereinafter referred to as "the Code". On completion of the construction of the ship, or as soon as practicable thereafter, measurement of noise levels in all spaces specified in chapter 4 of Annex 1 of the Code shall take place under the operating conditions. Measurements taken must following Chapter 3 of Annex 1 of the Code; and to be taken with the ship in the loaded or ballast condition. The course of the ship shall be as straight as possible. The actual conditions during the measurements shall be recorded on the survey report. Provide a copy of the survey report of the measurements taken during the operational conditions of the vessel while at sea as per 3.3 of Annex 1 of the Code. To ensure an acceptable quality, the measurements need to be taken by a institute or expert which support a quality management system according to ISO 17025. Provide a plan for testing by 14 March 2024, accepted by USCG and American Bureau of Shipping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2025
Resolution: Converted to Special Note. Extended to 14Mar2030.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 February 2024 Resolved
It has been found during the installation of the INERGEN system on the next of the National Security Multi-Mission Vessel, (Patriotic State II) that the nozzles being installed were the wrong size (SECDELBAY notified SECNY). It was verified that the incorrect nozzles have also been installed on the Empire State. Fire-fighting systems shall be kept in good working order and readily available for immediate use. 705 Until the correct nozzles are installed you are to limit the operation of internal combustion machinery to one(01) generator, additionally you may not operate the incinerator.
Action required: 705 - Other - as specified
Resolved 26 March 2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 February 2024 Resolved
Structural fire protection including fire resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. 705 Prior to the closing of the areas where the wire runs for the fire door indicators, the effective draft stop and bulkhead penetrations are to be inspected to the satisfaction of the USCG
Action required: 705 - Other - as specified
Resolved 23 February 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2024 Resolved
All ships which undergo repairs, alterations, modifications and outfitting related thereto shall continue to comply with at least the requirements previously applicable to these ships. Wiring has been modified for the FAIN Water Based Local Water Mist system, which serves the 4 main generator engines, emergency generator, and incinerator. The modifications included the addition of relays & timers. These modifications require approval IAW NVIC 10-92. The modifications also affect the DVTPs and PSTPs for the FAIN Water Based Local Water Mist system, which will need to be amended and approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 3 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 7 February 2024 Resolved
Installation tests of the starboard marine evacuation systems (MES) was subjected to a harbor trial deployment in July 2023. The port MES deployment should be similarly deployed within 12 months of the installation date (March 2024). The operator has requested an extension of 5 months (from 03/2024 out to 08/2024) to place all MESs on the same schedule, in addition there are weather challenges in March, along with the logistical challenges associated with the mobilization of people and equipment for the deployment and servicing of these MESs. In addition, given the approximate 3-to-4-week turnaround time required to service these MESs, this reduces the time that the ship would be unavailable for deployment if a humanitarian assistance / disaster relief mission was requested. In addition, the servicing of MES shall not exceed intervals of 12 months, the Administration may extend this period to 17 months. An extension of 5 months of the deployment and servicing of the port MES is granted. To be conducted no later than 31 August 2024
Action required: 705 - Other - as specified
Due 24 August 2024
Resolved 12 November 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2024 Resolved
Vessel's safety management system (SMS)must contain documented policies and procedures to ensure compliance with the reporting and after-action summary requirements of 46 U.S.C. § 10104 related to harassment, sexual harassment, and sexual assault. The SMS must establish a program of drills and exercises at an interval that is appropriate for each identified risk. In addition, vessel policies and procedures for conducting and documenting training on SA/SH reports and surveillance associated with a report must be included in the SMS. Vessels that are required to maintain displayed information IAW 46 USC 11101 should incorporate processes and procedures within the SMS to ensure compliance with the Code and CVC Policy Letter 23-04. Prior to sailing, update vessel's SMS to include the required provisions for the display of signage and crew training for the requirements contained in 46 USC 4901 and 46 USC 10104.
Action required: 705 - Other - as specified
Resolved 3 June 2024
Resolution: Title 46, United States Code (U.S.C.) §4901 and Title 46, United States Code (U.S.C.) §10104,-CVC-WI-004(3)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 December 2023 Resolved
At all times, while the ship is in service, fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Prior to sailing demonstrate that the sprinkler system on the ro/ro deck is operational, the system has been drained, as there is a possibility of the lines freezing and is not ready for immediate use. Provide proof of operation in all/any weather conditions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
Resolution: System was charged and intentions are to install heater s in/on the ro/ro deck
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 December 2023 Resolved
The use of approved fire-fighting equipment, (approved means approved by the Commandant) which conforms to the specifications of the Coast Guard...may be accepted for use. The ship has foam applicators with a Coast Guard Approval Number: 162.163/1/0, with an expiration date of 02 November 2011, with an approval status of “Former may use”, which means that if that piece of equipment was purchased before 02 November 2011, it may still be used provided that the equipment is still serviceable. Any of these items place on-board after that date is not approved. Provide approved equipment on-board the ship prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
Resolution: MARAD was able to locate 1% foam acceptable to us by USCG Eng.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2023 Resolved
The condition of the ship shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. On the Platform (04) deck aft of the training bridge (frame160), electrical space there is a possible hazardous condition. When you step in the space there are 2 steps down but no handrail on the open side which is a drop of approximately 24” which possess a possible hazardous condition (falling). Install handrail. Note ensure other similar spaces/situations are remedied.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2024
02 - Structural Conditions › N/A - No Subsystem › Damage control plan
Issued 9 November 2023 Resolved
There shall be permanently exhibited, or readily available on the navigation bridge, for the guidance of the officer in charge of the ship, plans showing clearly for each deck and hold the boundaries of the watertight compartments, the openings therein with the means of closure and position of any controls thereof, and the arrangements for the correction of any list due to flooding. There is no Damage Control Plan on the bridge. Post an approved Damage Control Plan on the bridges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 November 2023 Resolved
Waste receptacles shall be constructed of noncombustible materials. On the ro/ro deck there are numerous plastic (Rubbermaid) trash cans. Provide proof that they are non-combustible or remove.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2023
Resolution: Received email with trash cans that are acceptable
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 November 2023 Resolved
Attention should be given to the effectiveness of escape routes by ensuring that escape routes shall be provided from every normally occupied space on the ship to an assembly station. Escape routes shall be arranged so as to provide the most direct route possible to the assembly station and shall be marked with symbols based on the guidelines developed by the Organization. Refer to the Symbols related to lifesaving appliances and arrangements adopted by the Organization by resolution A.760(18) Recalled by Resolution A.1116(30). There are many signs that are placed in incorrect positions, many spaces are difficult to locate the exits. The signs used throughout “Lobby” are not in compliance with the IMO Resolution. It appears the Lifesaving Plan is correct it is the labeling/marking that is incorrect. Recommend a qualified person is to go through the ship and ensure that the signage is correct and meets the Resolution A.1116(30).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 November 2023 Resolved
Illustrations and instructions in appropriate languages shall be posted in passenger cabins to inform passengers of their muster station, the essential actions they must take in an emergency; and the method of donning life-jackets. Many of the cabin instructions are incomplete and are mirror images of the instruction on the opposite side of the ship. In addition, as per the MSC/Circ. 699 Revised Guidelines for passenger safety instructions the passenger cabins on each deck should also be numbered, increasing from forward to aft of the ship. The cabin numbering is very confusing and should be easily to tell one’s location.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 November 2023 Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements which provide an equivalent level of safety. In the Auxiliary Machinery Room 1 (AMR1), a Grey Water Discharge Control to AMR1 Grey Water Lift Station Remote Operated Valve is not connected, connect the valve
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2024
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 November 2023 Resolved
Fire protection systems, structural fire protection including fire resisting divisions, and protection of openings and penetrations shall be kept in good order so as to ensure their required performance if a fire occurs in these divisions. In the Auxiliary Machinery Room 2 (AMR2), a section of the starboard forward overhead fire protection/ insulation is missing. As per the vessel provided, Fire Protection and Insulation Plan, drawing number NSMV-635-B801 Sheet 30-1 of 34, Revision 6, shows that A-15 should be installed in the area observed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 November 2023 Resolved
Fire protection systems, structural fire protection including fire resisting divisions, and protection of openings and penetrations shall be kept in good order so as to ensure their required performance if a fire occurs in these divisions. In the Air Handling Unit Room 1 (AHU rm 1), an upper bulkhead penetration is not made tight to prevent the passage of flame and smoke. SOLAS 2020 Consolidated II-2 14/2.1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 November 2023 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs, structural fire protection including fire resisting divisions, and protection of openings and penetrations in these divisions. "A" class divisions are those divisions formed by bulkheads and decks which comply with the following criteria…they are constructed as to be capable of preventing the passage of smoke and flame to the end of the one-hour standard fire test. You can feel drafts passing through many of the “A” Class sliding fire doors in the stairways. In the presence of a USCG Marine Inspector demonstrate by the use of a smoke machine that the doors meet the “A” Class Criteria.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2023
Resolution: It was found that the draft was coming from the air handlers not the doors
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 26 October 2023 Resolved
Where electrical power is necessary to restore propulsion, that capacity shall be sufficient to restore propulsion from dead ship condition within 30 minutes after black out. Prior to the carriage of cadets/passengers USCG Marine Inspectors to observe a “Transitional Power Test” at night, using the procedures attached to include the restoration of propulsion.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2023
Resolution: System is capable of restart within the 30 minute's as required after blackout
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 October 2023 Resolved
Indication whether each door on a stairway enclosure is closed shall be provided at the fire door indicator panel at the control station. Stairway doors currently do not indicate on the bridge. Permanent solution/installation due on March 7, 2024. However, monthly provide progress status of the installation to Sector New York Inspections department. Until indication system is permanently installed, monitor doors in accordance with "Tote Services - Risk Assessment for Sliding doors" dated September 6, 2023.
Action required: 705 - Other - as specified
Resolved 23 February 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2023 Resolved
Interior nozzles are 1.5", however the Water Fog Applicators fit nozzles 2.5" nozzle. Provide 1.5" to 2.5" adapter with each water fog applicator until the correct applicator is supplied.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 October 2023 Resolved
Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat and stowed in a state of continuous readiness so that two crew members can carry out preparations for embarkation and launching in less than 5 min. Due to the modifications made and the extra steps in place to launch the boats. Demonstrate to the USCG Marine Inspector a safe and timely launching of each lifeboat. Prior to carrying cadets/passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2023
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 26 October 2023 Resolved
Passenger ships shall be fitted with a suitably located means to recharge breathing air cylinders. Breaker on electrical outlet trips whenever SCBA compressor is used. Investigate cause and make permanent repairs/alterations. Prior to carrying cadets/passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 26 October 2023 Resolved
"A" class doors located in stairways, public spaces and main vertical zone in escape routes shall be equipped with a self-closing hose port. Many of the hose ports are difficult to open due to the height of the deck material. In addition, the hose ports have dead bolts installed to keep them closed. Before sailing with cadets/passengers demonstrate that the hose port doors can swing all the way open, and provide documented proof from the manufacture that the dead bolts have been approved by Class DNV Certificate of Conformity MEDB00006AU
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 October 2023 Resolved
At least two widely separated and ready means of escape shall be provided from all spaces and shall meet the following functional requirements. Doors leading out to the open deck port and starboard side main deck, in way of lifeboats #4 / #5 don’t swing open all the way and the emergency exit path is blocked by vents. Submit Evacuation Analysis Escape Plan NSMV-623-B101 for review of these areas to ensure that the exits are adequate. Prior to carrying cadets/passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 October 2023 Resolved
Passenger ships shall carry at least one rescue boat complying with the requirements of section 5.1 of the Code on each side of the ship and shall be capable of carrying a person lying on a stretcher. Demonstrate to the attending USCG Marine Inspector that a stretcher/patient can safely be placed inside lifeboat #7/rescue boat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 26 October 2023 Resolved
Means of escape markings must enable persons to identify the routes of escape and readily identify the escape exits. Throughout the vessels the present signage is insufficient to identify escape routes. Provide additional signage to ensure that the escape routes are easily identified.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 October 2023 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. On the port and starboard side main weather decks leading to the Bow/Forecastle, the overhead light fixture wiring is being cut/chafed by the overhead sheet metal where the wiring enters the overhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Helicopter landing and pick-up area
Issued 26 October 2023 Resolved
Before the helideck on the vessel can be used for landings or touch/goes, the vessel must meet the functional requirements; structure must be adequate to protect the ship from the fire hazards associated with helicopter operations; firefighting appliances shall be provided; refueling if available shall provide measures to protect the ship from the fire hazards associated with helicopter operations; and operation manuals and training shall be provided to the crew.
Action required: 705 - Other - as specified
Resolved 20 December 2023
Resolution: Recived letter from MARAD December 20, 2023 MEMORANDUM FOR NATIONAL SECURITY MULTI-MISSION VESSELS (NSMV) SUBJECT: Directive-type Memorandum (DTM) 23-001 – Helicopter/Aircraft Operations