Tonnage as PSIX records it34629 - Convention (Subpart B), Gross Ton 20170 - Convention (Subpart B), Net Ton 61087 - Dead Weight, Metric Ton 72395 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
17 October 2025PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8249912
29 January 2024PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7850964
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 January 2024Resolved
No direct access shall be permitted between the machinery space and the space containing the emergency fire pump and its source of power. When this is impracticable, the administration may accept the arrangement where the access is by means of an airlock with the door of the machinery space of "A-60" class standard and the other door being at least steel, both reasonably gastight, self-closing and without any hold back arrangements. PSCO observed self closing door leading to steering room not fully closing. Issue was fixed on the spot by ships crew. 74SOLAS (2020) 11-2/10.2.2.3.2.2
Action required: 10 - Deficiency Rectified
Due 29 January 2024
Resolved 29 January 2024
Resolution: Crew fixed while CG was on board.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 20 June 2020Resolved
"The function of the fixed fire detection and fire alarm system shall be periodocally tested to the satisfaction of the administration by the means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having range of density or particles size, or other phenomena associated with incipient fires to which the detector is designed to respond" Vessel does not have the means to test UV fire alarm under F/O purifier.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 June 2020
Resolved 17 July 2020
Resolution: Vessel acquired the equipement to conduct the test of the UV Fire detector.