ANCHOR FPU is a industrial vessel. The Coast Guard has recorded 6 inspections since 2019, most recently in November 2025, along with 1 deficiency.

Records from 2019 to 2025. Most recent: inspection, 12 November 2025.

Built
Not recorded
Last inspected
12 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2019–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1612421
Flag
UNITED STATES
Maury page id
psix-1612421

Documentation record

Tonnage as PSIX records it18830 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

12 November 2025 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8267416
23 May 2025 Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8144943
20 March 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7894305
6 May 2020 Administrative Inspection · Construction Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6956998
6 May 2020 Construction Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7582615
26 November 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7135112

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2020 Resolved
Each accessible space must be sprayed with at least two effective spray patterns of water from separate hydrants. Add two fire hydrants IWO NW/SW BSDV Platform Top Decks. 46 CFR 108.423 Prior to COI
Action required: 705 - Other - as specified
Resolved 30 March 2023
Resolution: Hose reels and FW piping system was added to each of the platform top decks.

Ownership record