Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it20839 - Convention (Subpart B), Net Ton 35835 - Convention (Subpart B), Gross Ton 63445 - Dead Weight, Metric Ton 74836 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
10 September 2025PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8230423
26 October 2023PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7811777
5 June 2023Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7692244
3 July 2020PSC A
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6979255
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 September 2025Resolved
"The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: .1 structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions". 05 self-closing doors did not fully secure. 74 SOLAS (20) II-2/ 14.1.1.1; Deficiency Rectified; To the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 September 2025
Resolved 10 September 2025
Resolution: Corretced on the spot.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.