Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it63682 - Dead Weight, Metric Ton 75276 - Displacement, Metric Ton 35906 - Convention (Subpart B), Gross Ton 32936 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 6
11 August 2025PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8207070
5 August 2025VRP Review
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8202605
16 June 2022Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7479049
14 June 2022PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7477048
30 May 2022Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7463322
29 March 2021PSC A
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7165064
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 June 2022Resolved
Boilers shall be provided with means to supervise and control the quality of the feed water. Suitable arrangements shall be provided to preclude, as far as practicable, the entry of oil or other contaminants which may adversely affect the boiler. PSCO observed oil accumulation in the vessel’s cascade and inspection tank.
74 SOLAS (20) II-1/32.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2022
Resolution: Inspected cascade and inspection tank and found no free floating oil or debris. Tested OCM and alarms for cascade tank; all found in good order.