Records from 1989 to 2016. Most recent: inspection, 7 October 2016.
Documentation record
Registered dimensions (L × B × D)71.5 ft × 32.0 ft × 6.8 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORS INC · HARVEY, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Net Ton
94 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 44
7 October 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6018341
21 October 2015
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5747859
8 August 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4947914
9 May 2012
Inclining Experiment · Drydock Exam · COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4307370
9 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4241218
1 December 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3642652
20 November 2008
Annual Inspection · Ballast Water Examination · Administrative Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3366755
28 December 2007
Annual Inspection · Deficiency Check · Examination of Repairs · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3121779
12 October 2006
Hull Examination · Ballast Water Examination · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2798964
29 March 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2611780
24 January 2006
Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2572378
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539865
15 December 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2259980
27 September 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2206672
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972230
3 December 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1958111
23 January 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1734259
3 October 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403428
1 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350279
6 August 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446816
21 October 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447876
19 August 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459335
20 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115719
22 October 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 764415
10 October 1996
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467487
10 September 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 204496
10 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 62143
20 July 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392275
13 March 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1175471
18 July 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422391
29 March 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405508
13 December 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 849518
9 June 1993
Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376988
7 June 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 827727
28 April 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373847
2 September 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1270483
28 May 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463738
11 April 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918254
27 December 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228609
24 September 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215404
1 May 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929701
2 February 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929756
30 November 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926940
20 March 1989
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205505
Stability › Incline Test › General
Issued 31 July 2012
Resolved
Vessel added new starboard crane and is scheduled to perform stability test on 03 Aug 2012. Pending MSC issuing new stability letter, vessel's variable deck load is decreased to 60.6 short tons.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 October 2015
Resolution: Company provided approved stability letter.
Accommodation/Occupational Safety › Ventilation › General
Issued 31 July 2012
Resolved
Galley range exhaust hood is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Resolution: Hood was replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 July 2012
Resolved
Galley range was missing sea rails.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Resolution: Sea rails were installed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 31 July 2012
Resolved
Coffee maker and milk dispenser were not secured.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Resolution: Items were secured.
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 July 2012
Resolved
Main deck valves were not labled.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Resolution: Labeled.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 July 2012
Resolved
Exhaust lagging on both main engines was missing in several areas.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Resolution: Lagging was installed as indicated.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 July 2012
Resolved
Several items in first aid lockers were expired. Crew to inventory.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Resolution: Lockers were inventoried and items replaced.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 31 July 2012
Resolved
Engineroom bilge alarm did not work.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Resolution: Bilge alarm replaced.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 20 November 2008
Resolved
Conduct Hydro test of Air receiver due to unauthorized welded repairs to tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 14 January 2009
Personnel › Training › Familiarization Training
Issued 28 December 2007
Resolved
Demonstrate proficiency of crew in performing basic shipboard drills, or provide alternate competent crew prior to vessel getting underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2008
Resolved 31 January 2008
Resolution: Replaced crew.
Lifesaving
Issued 6 August 1999
Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District's policy Ltr."Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Unknown
Issued 27 December 1990
Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Unknown
Issued 30 November 1989
Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO THE [name withheld] FOR APPROVAL AND PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Unknown
Issued 30 November 1989
Resolved
SUBMIT FOR APPROVAL PLANS SHOWING GENERAL ARRANGEMENT, INBOARD/OUTBOARD PROFILE, FIRE CONTROL AND STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld].
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Documentation
Issued 20 March 1989
Resolved
PROVIDE APPROVED STRUCTURAL AND ENGINEERING PLANS FOR THE VESSEL.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Documentation
Issued 20 March 1989
Resolved
PROVIDE APPROVED STABILTIY BOOKLET AND OPERATING MANUAL.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989