Records from 2020 to 2026. Most recent: inspection, 27 April 2026.
Inspection history · 9
27 April 2026
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8356881
20 April 2026
PSC B · COC-CVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8349712
9 March 2026
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8323420
20 October 2025
COC-CVE Quarterly · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8253080
11 September 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8231613
22 April 2025
COC-CVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8116528
26 October 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024713
23 April 2024
PSC A · COC-CVE Initial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7897686
23 June 2020
COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 6984548
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 April 2026
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed fire door 9.2.12 did not close and latch completely. 74 SOLAS 20 II-2/9.4.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 April 2026
Resolved 20 April 2026
Resolution: They were able to adjust the door on the spot to close.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 October 2025
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All lifeboats shall be capable of controlling the rudder or tiller. Observed life boat #8 unable to control rudder by primary means.
74 SOLAS 20 III/34
LSA Code 4.4.4.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2025
Resolved 21 October 2025
Resolution: Emailed proof to MI, cleared upon review.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 April 2024
Resolved
Alleyways, stairways and exits giving access to the muster and embarkation stations shall be lighted. Such lighting shall be capable of being supplied by the emergency source of electrical power. PSCO identified 03 inoperable emergency lights in the following locations: Deck 14-Stair 275, Deck 10-Stair 115, and Deck 8-Stair 340.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2024
Resolved 23 April 2024
Resolution: PSCO observed the functionality of all three lights prior to departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 April 2024
Resolved
The following functional requirements shall be met: additional aids for escape shall be provided as necessary to ensure accessibility, clear marking, and adequate design for emergency situations. PSCO identified exit sign in alternator room, deck c, did not indicate proper direction for exit.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 April 2024
Resolved 23 April 2024
Resolution: PSCO verified that the exit sign was replaced with one that pointed in the proper direction of egress prior to departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 April 2024
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO identified double leaf fire doors not properly closing and latching on doors 6.5.06 and 7.5.05.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2024
Resolved 23 April 2024
Resolution: PSCO witnessed proper operation of both doors prior to departing the vessel.