TED COOK is a 1998 towing vessel. The Coast Guard has recorded 3 inspections since 2021, most recently in December 2024, along with 11 deficiencies — 5 with no resolution recorded —.
Records from 2021 to 2024. Most recent: inspection, 18 December 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it101 - Regulatory (Subpart C or D), Net Ton 339 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2025No resolution recorded
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Existing grid cooler leak for the port main engine ring gear.
Vessel shall make repairs to the grid cooler at drydock. Recommend a CG marine inspector attend drydock to oversee repairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 January 2025No resolution recorded
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
Engine room escape hatch is seized closed. Make repairs to ensure emergency escape hatch functions as designed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025 — due date passed with no resolution recorded
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention.
The following alarms must be provided:
(1) Main engine low lubricating oil pressure;
(2) Main engine high cooling water temperature;
(3) Auxiliary generator engine low lubricating oil pressure;
(4) Auxiliary generator engine high cooling water temperature;
(5) High bilge levels;
(6) Low hydraulic steering fluid levels and
(7) Low fuel level, if fitted with a day tank.
Alarm set-points for the above mentioned alarms have not been tested. Bilge alarms could not be accurately identified and corresponded with the alarm panel.
Conduct alarm set-point testing and bilge alarm test with an operable panel in the presence of an attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 January 2025No resolution recorded
The following systems must be equipped with gauges at the machinery location:(1) Main engine lubricating oil pressure and main engine RPM;(2) Main engine cooling water temperature;
Digital panel on main engines does not display lubricating oil pressure, engine RPM, or cooling water temperature. There are no additional gauges installed to verify parameters.
Repair digital control panel to display applicable parameters or install required gauges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 January 2025No resolution recorded
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates.
Visual distress signals onboard are expired. Replace visual distress signals in accordance with the carriage requirements indicated in Table 141.370.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 October 2023Resolved
Ground found on phase "A".
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2023
Resolved 16 November 2023
Resolution: RCVD email that two Master Electricians tested and state its a false reading.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 October 2021Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: The system is installed, tested, and maintained in accordance with the manufacturer's design manual.
The Fire detection panel is inop and producing audible and visible alarm when power is applied to the panel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 October 2023
Resolution: Verified the fire detection panel is functioning as designed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 October 2021Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section.
The installed portable fire extinguishers and fixed fire detection systems inspections have expired and need to be serviced.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 October 2023
Resolution: Verified fire extinguishers and detection system have been serviced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 October 2021Resolved
Fixed fire-extinguishing systems must be inspected and tested, as required by table 142.240 of this section, in addition to the tests required by §§ 147.60 and 147.65 of subchapter N of this chapter.
The pressure switches on the fixed CO2 system were found inop during testing of shutdowns for ventilation and main machinery.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 October 2023
Resolution: Verified fixed-firefighting system had been inspected by an aproved servicing company.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 5 October 2021Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following:
(a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.(b) Storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable.
The STBD AFT fuel tank supplying the SSDG's is leaking and accumulating diesel fuel in the #4 STBD void space.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 October 2023
Resolution: Verified the leak in the aft fuel tank was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2021Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover.
The remote fuel shut-off valves outside the space were inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 October 2023
Resolution: Verified satisfactory operation of remote fuel shut-off valves.