MAURY USCG vessel records
← All vessels

J GENE CRUMP

J GENE CRUMP is a 1970 towing vessel. The Coast Guard has recorded 7 inspections since 2021, most recently in January 2026, along with 25 deficiencies.

Records from 2021 to 2026. Most recent: inspection, 19 January 2026.

Built
1970
Last inspected
19 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 19 January 2026
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2021–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1621680
Flag
UNITED STATES
Maury page id
psix-1621680

Documentation record

Tonnage as PSIX records it250 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

19 January 2026 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8288408
26 February 2025 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8085273
18 January 2024 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7850605
3 February 2023 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7631546
17 January 2023 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7621046
20 January 2022 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7383569
19 January 2021 COI Inspection · Deficiency Check · Initial Certification
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7170479

Deficiency record · 25

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 January 2023 Resolved
The fire detection system was last inspected by a certified technician on Jan 2021. System is required to be inspected/serviced IAW manufacturer's instruction.
Action required: 705 - Other - as specified
Due 24 January 2023
Resolved 26 January 2023
Resolution: Technician serviced the alarm system and placed a new tag on the panel. Email showed new tag and the Captain attested to it's servicing. -ZAP
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 17 January 2023 Resolved
Fire extinguisher located in the forward void space was found to be overdue for annual servicing.
Action required: 705 - Other - as specified
Due 24 January 2023
Resolved 26 January 2023
Resolution: Fire extinguisher was serviced with a new tag placed on it. Viewed email with picture showing new tag and the Captain attested to its servicing.-ZAP
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 January 2023 Resolved
First aid station was found to be expired upon inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2023
Resolved 2 February 2023
Resolution: New first aid kit was installed in place of the expired kit. Received email with picture showing the expiration date and installation of the new kit. -ZAP
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 January 2022 Resolved
Installed life rings were found with missing retro-reflective material.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 18 February 2022
Resolution: Vessel Owner replaced the retro on the life rings. Photos were sent to MSD Fort smith to prove that the def was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 January 2021 Resolved
Fire extinguishers need to be serviced fixed/portable
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Extinguishers were serviced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 January 2021 Resolved
Fixed bottles need hydro test
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 February 2021
Resolved 4 February 2021
Resolution: Bottles were hydro tested.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 19 January 2021 Resolved
Fixed bottles hydro test
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Station bill was posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 January 2021 Resolved
Properly mount extinguisher on bridge
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Properly mounted extinguisher on bridge
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 January 2021 Resolved
Pilot house smoke alarm
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Pilot house smoke alarm installed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 January 2021 Resolved
Professional Engineer letter for fire detection system
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Provided fire detection system approval.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 January 2021 Resolved
140.915 Items to be recorded. (a) The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: (1) Personnel records, in accordance with §140.400; (2) Safety orientation, in accordance with §140.410; (3) Record of drills and instruction, in accordance with §140.420; (4) Examinations and tests, in accordance with §140.615; (5) Operative navigational safety equipment, in accordance with §140.620; (6) Navigation assessment, in accordance with §140.635; (7) Navigation safety training, in accordance with §140.645; (8) Oil residue discharges and disposals, in accordance with §140.655; (9) Record of inspection of towing gear, in accordance with §140.820; and (10) Fire-detection and fixed fire-extinguishing, in accordance with §142.240.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Provided record keeping system to include required items, vessel shifted to online based system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 January 2021 Resolved
Floating Lights on life ring
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Installed floating Lights on life ring
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2021 Resolved
Instructions for fuel shutoff
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Instructions for fuel shutoff posted
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 January 2021 Resolved
Hull # stamped in E/R
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Hull # was stamped in E/R
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 19 January 2021 Resolved
Oil discharge Placards
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Oil discharge Placards posted
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 19 January 2021 Resolved
Garbage Placards
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Garbage Placards posted
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2021 Resolved
Non-conductive mat under switchboard
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Non-conductive mat installed under switchboard
08 - Alarms › N/A - No Subsystem › General alarm
Issued 19 January 2021 Resolved
General Alarm Light/sign
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: General Alarm Light/sign installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 January 2021 Resolved
Life jacket on bridge
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Life jacket stored on bridge
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 19 January 2021 Resolved
Fall overboard Prevention Procedure
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Provided Fall overboard Prevention Procedure
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 January 2021 Resolved
Alcohol test strips
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Provided alcohol testing procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 January 2021 Resolved
Expired distress signals
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Distress signals purchased
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2021 Resolved
Provide compressor safety relief valve setting
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Installed new compressor safety relief valve.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 19 January 2021 Resolved
Towing gear records 46 CFR 140.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Provided towing gear records
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 January 2021 Resolved
Health and Safety Manual
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 4 February 2021
Resolution: Provided Health and Safety Manual

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.