GAR is a 1978 offshore supply vessel. The Coast Guard has recorded 54 inspections since 1990, most recently in May 2026, along with 28 deficiencies and 1 casualty investigation in 2006.

Records from 1990 to 2026. Most recent: inspection, 18 May 2026.

Built
1978
Last inspected
18 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7832000 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH5167
162222
Flag
UNITED STATES
367625190
Maury page id
psix-162222

Inspections, by type

…with no type recorded8
Years with a record 32 calendar years (1990–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)71.5 ft × 48.6 ft × 6.8 ft
Registered tonnagegross 98 / net 74
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORS INC · HARVEY, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP9623MMSI 367625190 · active · compulsorily equipped · granted 15 January 2025, expires 15 January 2035
WDH5167MMSI 367625190 · expired · compulsorily equipped · granted 4 June 2014, cancelled 10 August 2024
WDC4888MMSI 367032380 · expired · compulsorily equipped · granted 9 April 2005, cancelled 13 June 2015
WDB7765MMSI 366947710 · expired · compulsorily equipped · granted 14 May 2004, cancelled 19 July 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

18 May 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8375891
28 January 2026 Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8303485
30 December 2025 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8286363
11 December 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8283507
26 February 2025 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8085269
26 March 2024 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7886912
13 December 2023 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7838744
12 September 2022 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7543226
2 June 2022 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7467413
10 January 2022 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7378039
8 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6638501
25 February 2019 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6632880
5 July 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6467938
11 August 2017 Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6243182
27 March 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6112048
28 September 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6011351
11 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5852201
24 November 2015 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5769768
24 November 2015 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6018466
6 March 2014 Annual Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4811067
30 June 2012 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4373183
2 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3643342
17 February 2009 Ballast Water Examination · Hull Examination · Examination of Repairs · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3425032
10 November 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3360458
7 August 2008 Administrative Inspection · Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3291518
26 July 2007 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3008098
24 July 2007 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3005991
14 March 2006 COI Inspection · Hull Examination · Examination of Repairs · Ballast Water Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2633678
21 February 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2592867
23 November 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539870
15 December 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2259999
29 January 2004 Hull Examination · Re-Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1996190
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972250
9 July 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1846068
24 April 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1608580
15 March 2001 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418862
12 April 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453734
28 January 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365030
22 December 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427597
30 October 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381053
28 December 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1094498
21 November 1996 COI Inspection · Hull Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354053
16 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1175468
25 January 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1135758
25 July 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422390
7 October 1993 Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461539
27 April 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 644260
25 April 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 120216
9 December 1992 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432640
2 September 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1270484
21 July 1992 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426717
25 July 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938961
24 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913887
18 July 1990 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900836

Deficiency record · 28

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 May 2026 Resolved
All observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel was mobilized for a backload operation with gasbuster that had Class 1 Div 1 zones over most of deck including where lights, electrical switches, engine room ventilation, escape hatch, etc were inside HAZ ZONE. 705 - Prior to backload operations.
Action required: 705 - Other - as specified
Resolved 17 June 2026
Resolution: Received email from [name withheld] stating backload was not done and equipment off. Vessel is currently working offshore doing other operations not associated with backload/flowback.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2026 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment. Vessel was observed with aft leg removed completing weld repairs to leg tower and leg pipe internal support structures. No notification to cognizant OCMI was made. Marine inspector to verify repairs and non destructive tests are complete before vessel departs from shipyard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2026
Resolution: Repairs completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2025 Resolved
The following piping systems must be hydrostatically leak tested in the presence of a marine inspector at a pressure of 1.5 times the maximum allowable working pressure of the system: Any Class I, I-L, II-L piping. Several jacking system hydraulic brake pressure and brake lines were being replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2025
Resolution: Vessel renewed hydraulic piping to leg brake systems on all three legs and were pressure tested to the satisfaction of the attending MI with satisfactory results.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 December 2025 Resolved
As appropriate for the intended voyage,all vessels must carry adequate and up-to-date (a) Charts. Vessel's charts were last updated 2022 and did not have an approved electronic chart display. 46 CFR § 185.20-35(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2025
Resolution: Vessel updated Rose Point electronic chart system to commercial version and MI observed declaration of conformity.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 December 2025 Resolved
At all inspections special attention shall be paid to insure that no fire hazards exist and that guards or protective devices are provided in all hazardous places. Both port and stbd gensets were covered in oil and had excessive accumulation of oil and oil soaked absorbent pads underneath. 46 CFR 176.25-10(7)(b).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2025
Resolution: Vessel removed excess oil from generators and generator bilges.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 December 2025 Resolved
All ducts shall be of rigid permanent construction of fire proof material and reasonably gastight from end to end. Both port and stbd main deck engine room vetilation closeures had wastage allowing air to enter space when closed. 46 CFR 182.20-45(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2025
Resolution: Vessel made necessary repairs to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 December 2025 Resolved
At each reinspection the firefighting equipment of all vessels shall be inspected and all deficiencies found shall be corrected. During fire pump test noted a leaking pipe nipple approx 12" above deck leading to port fire hose station. 46 CFR 176.25-25(a).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2025
Resolution: Fire main was operationally tested without leaks.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 December 2025 Resolved
At all inspections special attention shall be paid to insure that no fire hazards exist... the port engine room shaft rose box had excessive accumulation of oil. Note that there is an automatic bilge pump installed in this area used to accumulate water and pump directly overboard. Oil was observed discharging directly overboard from the overboard piping system. 46 CFR 176.25-10(7)(b).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2025
Resolution: Automatic float switch was removed, and the pump is piped into the zero discharge tanks.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 11 December 2025 Resolved
At each...inspection...the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: (1) Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. The MI observed significant deck plating and support station cracking in vicinity of the aft port leg brace. Vessel shall make proper structural and watertight hull (weather deck) plating repairs prior to departure. 46CFR176.25-5(a)(1)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2025
Resolution: The deficiency is cleared and re-issued as a 14-day deficiency as explained in ACT#
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 February 2025 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) and your Certificate of Inspection must be endorsed. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The COI anniversary date is September 12 and expires on September 12, 2027. The vessel was required to have an annual inspection no later than December 2024. The vessel failed to schedule an annual inspection until February 18, 2025, and operated for approximately 2 months without a valid COI. Vessel shall ensure that it does not operate without a valid COI.
Action required: 10 - Deficiency Rectified
Due 26 February 2025
Resolved 26 February 2025
Resolution: Completed annual inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2025 Resolved
Exhaust gas must not leak from the piping or any connections. The port side main engine exhaust manifold was missing a plug and exhausting directly into the space causing a hazardous environment. Vessel shall install required plug prior to departure to the satisfaction of the attending marine inspector.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 26 February 2025
Resolved 26 February 2025
Resolution: Vessel installed plug on exhaust manifold.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks…The exhaust stack of the port generator, constructed on the port-side main deck, had an approximately 3”x3” waste hole located less than 1” above the deck, compromising the watertight integrity of the hull. Vessel shall make necessary repairs to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 February 2025
Resolved 26 February 2025
Resolution: Vessel welded patch in place.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 February 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Test of machinery alarms including bilge high level alarms. The starboard rudder room bilge audible alarm was inoperable at time of inspection. Vessel shall make necessary repairs to bring alarm system in compliance with 46CFR182.530(a).
Action required: 10 - Deficiency Rectified
Due 26 February 2025
Resolved 26 February 2025
Resolution: Vessel installed new speaker for bilge alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 February 2025 Resolved
Each ring life buoy on a vessel must: Be stowed in a way that it can be rapidly cast loose. During the man overboard drill, the crew could not deploy the ring life buoy rapidly as the attached lifeline was improperly stowed. Vessel shall install all lifelines attached to lifebuoys are properly stowed to allow for rapid casting to the satisfaction of the attending marine inspector.
Action required: 10 - Deficiency Rectified
Due 26 February 2025
Resolved 26 February 2025
Resolution: Vessel untangled and reinstalled life buoy and line.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 February 2025 Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Permanent watertight coamings must be provided…The coaming for the weathertight door access to the galley on the main deck was cracked in vicinity of the lower knife edge preventing watertight integrity. Vessel shall make necessary repairs to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 26 February 2025
Resolved 26 February 2025
Resolution: Vessel rewelded knife edge.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected… The port-side shaft seal compartment contained excessive oily water. This compartment is equipped with a portable bilge pump connected to piping leading directly overboard. Since the shaft seal allows water to accumulate in the compartment and requires periodic operation to drain, the vessel must ensure no oil accumulates in the space to prevent discharging oil overboard.
Action required: 10 - Deficiency Rectified
Due 26 February 2025
Resolved 26 February 2025
Resolution: Vessel cleaned excess oil.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 February 2025 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”…The port side engine space was missing the required marking. Vessel shall properly mark the escape hatch area to the satisfaction of the attending marine inspector.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 26 March 2025
Resolved 26 February 2025
Resolution: Vessel labeled escape hatches.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2025 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. The fluorescent bulb lighting fixture installed above the starboard propulsion engine was missing its protect guard. Vessel shall install the protective guard/covering to the satisfaction of the attending marine inspector.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 26 March 2025
Resolved 26 February 2025
Resolution: Vessel installed light fixture cover.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 September 2022 Resolved
Fuel shutoff valves at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. The port remote fuel shutoff valve was broken & inoperable from the weather deck fitting. Vessel to replace/repair prior to getting underway. 46CFR182.20-40(b)(3) OLD T.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2022
Resolution: Vessel repaired broken reach rod for the port remote fuel shutoff valve and witnessed by USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 September 2022 Resolved
All fire main piping, valves, & fittings shall be in accordance with good marine practice & suitable for the purpose intended. Both port & starboard engine room fire station open/close valves were seized in the closed position & could not be operated. Vessel shall replace/repair valves prior to getting underway. 46CFR181.15-5(c) OLD T.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2022
Resolution: Vessel replaced port valve and repaired stbd valve as witnessed by USCG Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 8 March 2019 Resolved
Provide valid compass deviation table at operating station
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2019
Resolved 8 March 2019
Resolution: Vessel had star marine attend vessel to complete deviation
Construction/Loadline
Issued 15 March 2001 Resolved
PROVIDE THIRD PARTY REPORT OF NDT TESTING OF PADS AND LEG TO PAD WELDS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 April 2001
Resolved 10 April 2001
Documentation
Issued 28 January 1999 Resolved
PROVIDE FOR REVIEW TO MORMS DAPA OFFICER THE COMPANIES CHEMICAL TESTING ANDEMPLOYEE ASSISTANCE PROGRAM AS REQUIRED BY 46 CFR PART 16; PROVIDE TRAININGUPON APPROVAL.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Documentation
Issued 21 November 1996 Resolved
PROVIDE ONBOARD THE ORIGINAL OP MANUAL REVIEWED BY MSC AND STAMPED "APPROVED" BY MORMS.
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Fire Fighting
Issued 7 October 1993 Resolved
01. PROVIDE FIRE PUMP WHICH THROUGH INDEPENDENT OPERATION MEETS REQUIREMENTS OF CFR 46 181.10-(c). FURTHER USE OF VESSEL IS NOT AUTHERIZED UNTIL DISCREPANCY IS RESOLVED.
Condition: Unknown
Due 12 October 1993
Resolved 14 October 1993
Documentation
Issued 18 July 1990 Resolved
SUBMIT AN OPERATING MANUAL, MEETING THE APPLICABLE SECTION OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Documentation
Issued 18 July 1990 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE, ANDA STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Documentation
Issued 18 July 1990 Resolved
SUBMIT STABILITY CALCULATIONS TO THE COAST GUARD MARINE SAFETY CENTER FOR ISSUANCE OF A STABILITY LETTER.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990

Casualty record · 1

21 February 2006Routine · role: Involved in a Marine Casualty · activity 2592867
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.