Records from 2016 to 2025. Most recent: inspection, 8 August 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)38.8 ft × 14.0 ft × 5.6 ft
Registered tonnagegross 22 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS, INC. · LOREAUVILLE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Net Ton
22 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
11 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 11
8 August 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8205207
6 August 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7975413
16 April 2024
Simplified Stability Test
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7896298
31 May 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7689778
10 September 2021
Examination of Repairs · Drydock Exam · Damage Survey · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7309413
4 May 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7189191
17 June 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6979336
13 August 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6781881
27 June 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6451881
15 May 2017
COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6142867
18 May 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5878806
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 May 2022
Resolved
A hatch exposed to the weather must be watertight. Gasket material for the vessel's machinery space hatch covers was found to be degraded or missing.
46 CFR 179.360(a)
10c
Action required: 10 - Deficiency Rectified
Due 7 June 2022
Resolved 24 May 2022
Resolution: Owner rep replaced gasket material for machinery space hatch covers.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 24 May 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of the cognizant OCMI, except during an emergency. MI observed 03 cracked welds on aft starboard overhead longitudinal stiffener frame in machinery space.
46 CFR 176.700(a)
10c
Action required: 10 - Deficiency Rectified
Due 7 June 2022
Resolved 24 May 2022
Resolution: Owner rep provided photographs documenting satisfactory repair of found cracked welds.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2021
Resolved
Prior to getting underway, and at all other times necessary to ensure the safety of the vessel, the master or officer in charge of a navigational watch must determine whether the vessel complies with all stability requirements in the vessel's trim and stability book, stability letter, COI, and Load Line Certificate, as applicable. Your vessel was involved in a marine casualty as a result of Hurricane IDA. A thorough examination must be conducted to evaluate the watertight integrity of the vessel. Any damage identified hindering the vessels safety, must be reported to the CG and your TPO, if applicable, and all repairs necessary need to be completed to the satisfaction of TPO. Submit a repair proposal prior to conducting repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2022
Resolved 4 April 2022
Resolution: All repairs examined and water lance tested to satisfaction of Marine Inspector. See attached repair plan for details.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2019
Resolved
Found 01 exposed wire and one wire disconnected on the backside of panel on bridge, Repaired on the spot.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2019
Resolution: Repaired while on inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 August 2019
Resolved
Starboard running light was inoperable. Fixed during inspection.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2019
Resolution: Repaired while on inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2019
Resolved
Missing 03 fire-buckets. Remedied on spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 August 2019
Resolution: Resolved while on inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 August 2019
Resolved
Life-ring light inoperable. Fixed during inspection.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2019
Resolution: Remedied while on inspection.