Records from 2020 to 2025. Most recent: inspection, 10 September 2025.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 18.0 ft × 7.0 ft
Registered tonnagegross 13 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCARANO BOATBUILDING INC · ALBANY, NY, UNITED STATES · built 2020
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portJERSEY CITY, NJ
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 8 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
10 September 2025
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8231066
24 January 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8069382
20 November 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8037976
2 October 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8014419
6 September 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7786284
22 November 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7600404
9 November 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7591872
3 November 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7588502
8 January 2022
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 7377251
16 December 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7368935
15 December 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7366923
28 September 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7321987
8 March 2021
Simplified Stability Test · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7152358
18 September 2020
Examination of Repairs · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7058349
21 February 2020
Simplified Stability Test · Construction Oversight · Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7042548
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 September 2023
Resolved
11116 - A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals and
three hand orange smoke distress signals. One of the following may be substituted for any of the hand orange
smoke distress signals required this section: a hand red flare distress signal. The vessel only had 4 red hand flares on board.
46 CFR 180.68(b) and (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2023
Resolution: Received photographic evidence of new flares.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 6 September 2023
Resolved
09237 - The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. The alcohol testing swabs on board the vessel were expired and need to be replaced.
46 CFR 4.06-15(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
Resolution: Received photogrraphic evidence of the alcohol test strips.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 September 2023
Resolved
13104 - visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The visual indicators for the automatic bilge pump are not visible.
46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 November 2024
Resolution: Deficiency was corrected to the ssatisfaction of the attending CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 September 2023
Resolved
07199 - Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The bracket for the fuel shutoff on the starboard side is broken.
46 CFR 182.455(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 November 2024
Resolution: Deficiency was corrected to the ssatisfaction of the attending CG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 November 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is prohibited from operations until a drydock examination and an internal structural exam has been completed by a US Coast Guard Marine Inspector
46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2022
Resolution: Conducted DD examination.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 September 2020
Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of the vessel. The emergency instruction onboard are not specific to the vessel. 46CFR 185.420(a)(3).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 13 November 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 September 2020
Resolved
Automatic shutdown all ventilation and engines. Tested fire boy system generator did not shutdown. 46CFR181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2020
Resolution: Attending marine inspector verified proper repair.