DEL MONTE ROSE is a 2020 freight ship. The Coast Guard has recorded 11 inspections since 2020, most recently in February 2025, along with 6 deficiencies.

Records from 2020 to 2025. Most recent: inspection, 16 February 2025.

Built
2020
Last inspected
16 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 February 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2020–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9849655
V7A4829
1629562
Flag
MARSHALL ISLANDS
Maury page id
psix-1629562

Documentation record

Tonnage as PSIX records it27802 - Dead Weight, Metric Ton
21391 - Convention (Subpart B), Gross Ton
9200 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

16 February 2025 In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8080089
16 February 2025 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8083799
10 December 2024 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8045464
16 July 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7959371
8 July 2024 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7952938
30 March 2024 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7885858
22 December 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7371512
14 November 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7351052
22 March 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7160405
21 September 2020 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7062043
20 September 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7060258

Deficiency record · 6

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 February 2025 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP, IN ALL RESPECTS, WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. WHILE TRANSITING INBOUND ON THE DELAWARE RIVER, THE VESSEL EXPERIENCED A MAIN ENGINE COOLING WATER FAILURE LEADING TO AN ENGINE OVERHEAT ALARM. ENSURE THE VESSEL'S MAIN ENGINE COOLING WATER SYSTEM IS IN SATISFACTORY CONDITION AND THE VESSEL'S MAIN ENGINE IS FULLY OPERATIONAL AND FIT TO PROCEED TO SEA PRIOR TO DEPARTURE FROM HOLT MARINE TERMINAL.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2025
Resolved 17 February 2025
Resolution: See attached class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 December 2024 Resolved
The machinery, boilers and other pressure vessel, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. [name withheld] a report from the vessel that the #8 cylinder on the M/E suffered fuel leaks leaving the cylinder in operable. 17ac 74SOLAS(20) II-1 26.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2024
Resolution: Class report submitted (attached)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 July 2024 Resolved
74 SOLAS (20) I/11.A THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMIAN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED INJECTOR USED FOR FUEL SUPPLY TO BOILER WAS MALFUNCTIONING.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 16 July 2024
Resolution: Boiler burner replaced. Boiler was functionally tested with satisfactory results.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure it remains fit for sea. Vessel reported hull damage in 02 locations, one of which a full penetration of ship's hull.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 15 November 2021
Resolved 15 November 2021
Resolution: Provided adequate survey from class.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Remote activation for CO2 Room ventilation does not work.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 September 2020 Resolved
Main and emergency switchboards shall be suitably guarded. Where necessary, nonconducting mats or gratings shall be provided at the front and rear of the switchboard. Generator Switchboards did not have nonconducting mats or gratings.
Action required: 10 - Deficiency Rectified
Resolved 21 September 2020

Ownership record