This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it49091 - Convention (Subpart B), Gross Ton 63483 - Dead Weight, Metric Ton 91895 - Displacement, Metric Ton 14728 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
18 December 2020Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7113801
11 December 2020Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7110167
13 August 2020VRP Review · PSC A
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7031891
13 August 2020Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7031917
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 August 2020Resolved
WHERE NECESSARY, NONCONDUCTING MATS OR GRATINGS SHALL BE PROVIDED AT THE FRONT AND REAR OF THE SWITCHBOARD. VARIOUS STARTER PANELS (440V) IN BOTH ENGINE ROOMS AND MOTOR ROOMS FOUND LACKING ELECTRICAL NONCONDUCTING MATS IN FRONT OF STARTER PANELS. PANELS FOUND LACKING: NO.1, NO.3, NO.4, NO.7, NO.11, NO.12, NO.8A, NO.8B.
74 SOLAS (14) II-1/45.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 18 December 2020
Resolution: Received reciepts for mats ordered on 21AUG20.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 August 2020Resolved
SUITABLE INSTRUCTIONS AND COMPONENT SPARES FOR TESTING AND MAINTENANCE SHALL BE PROVIDED. VESSEL LACKS THE MEANS TO TEST FLAME DETECTORS IN ENGINE SPACES.
74 SOLAS (14) II-2/7.2.2
FSS 9.2.5.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 18 December 2020
Resolution: Received receipts of flame detector tester ordered 22AUG2020.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.