This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it26329 - Convention (Subpart B), Net Ton 41830 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
7 October 2022PSC A
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7563760
7 October 2022In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7585593
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 October 2022Resolved
02199 - AFTER ANY SURVEY HAS BEEN COMPLETED, NO CHANGES SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED COMPRESSOR WITH HOSE SET UP IN BOSUN STORES. THE HOSE OBSTRUCTED CLOSURE OF A RESTRICTED AREA DOOR. 74 SOLAS (20) CHAPTER I/REG 11(b) - 50a.c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2022
Resolved 27 October 2022
Resolution: Received confirmation from vessel's class society attesting to the rectification of the deficiency.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.