Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)47.7 ft × 11.5 ft × 4.2 ft
Registered tonnagegross 22 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRAFTON · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Gross Ton 15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 July 2005Resolved
Place covers on all electric junction boxes on bridge and in crew room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 2 June 2010
Resolution: No issues noted concerning electrical panels during exam.
Communications › Alarms/Indicators › General Alarm
Issued 7 February 2002Resolved
General alarm onboard vessel is missing the required labeling and weekly testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2004
Resolved 10 August 2004
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 February 2002Resolved
Vessels remote fuel shut off system is missing the required labels. LEGACY COMPONENT DESC: Labels
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2004
Resolved 10 August 2004
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 7 February 2002Resolved
Vessels fire detection control panel is missing the rquired labels that indicate the location/origin of fire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2004
Resolved 10 August 2004
Communications › Alarms/Indicators › General Alarm
Issued 7 February 2002Resolved
General alarm is missing its own contact maker. It is currently tied into the fire detection control panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2004
Resolved 10 August 2004
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 7 February 2002Resolved
Vessels fire detection control panel is missing its certification letter from a Registered Professional Engineer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2004
Resolved 10 August 2004