Records from 2020 to 2023. Most recent: inspection, 25 April 2023.
Inspection history · 13
25 April 2023
COC-CVE Annual · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7674490
24 April 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7675966
9 October 2022
COC-CVE Quarterly · Deficiency Check · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7574002
12 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7449191
11 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7448574
25 April 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7437458
24 April 2022
COC-CVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7434543
13 October 2021
Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7331656
8 October 2021
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7329386
4 October 2021
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7326329
25 September 2021
COC-CVE Initial
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7318944
26 July 2021
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7268043
27 August 2020
COC-CVE Initial Prep
Type not classified · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7043554
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 25 April 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Found approximately 2 meter by 2 meter window pane (external pane) smashed and covered by plywood. Window is located in the starboard side, deck 5 approximately 8 meters above the waterline at frames 83/85, penetrating the side shell.
74SOLAS(20)I/11(a)
action: 16 a c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 3 May 2023
Resolution: Vessel repaired window. Received Class Report satisfactory to clear the deficiecncy.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 25 April 2023
Resolved
Each administration shall ensure that the provisions of the regulation are complied with, in order to recognize by endoresement in accordance with regulation I/2, paragraph 7, a certificate issued by or under the authority of another party to a master, officer. At time of inspection/exam, flagstate (bahamas) endorsement for the 2nd engineer (reg III/2) was expired
STCW I/10.1
action: 10 c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 April 2023
Resolved 25 April 2023
Resolution: 3 month extension issued by Bahamas
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 9 October 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2022
Resolved 29 October 2022
Resolution: On 29OCT22, PSCO onboard verified that the vessel acquired and had onboard adequate number of flash hoods.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2022
Resolved
Not less than one half of the total number of lifebuoys shall be provided with self-igniting lights. Deck 8 forward life buoy light was inoperable.
74 SOLAS 20 III/7.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2022
Resolved 11 May 2022
Resolution: Received class report showing that a new life ring buoy was purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 24 April 2022
Resolved
A line throwing appliance complying with the requirements of section 7.1 of the Code shall be provided. Two of the four line throwing appliances were not operationally ready.
74 SOLAS (20) III/18
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2022
Resolved 11 May 2022
Resolution: Received class report that clears out the deficiency
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 24 April 2022
Resolved
Performance of crew members assigned fire-fighting duties shall be periodically evaluated. The fire team did not properly don fire fighting equipment. SCBA masks were not fitted and hanging off 02 fire team members and gloves were not worn by one fire team member.
74 SOLAS (20) II-2/15.2.2.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 April 2022
Resolution: Conducted 2nd drill
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2022
Resolved
A fixed fire-extinguishing system may be any of the following. A fixed pressure water-spraying system complying with the provisions of the FFS Code. Means shall be provided for testing the automatic operation of the pump on reduction of pressure in the system. Section valve #813V2133 guage was inoperable.
74 SOLAS (20)II-1/10.4.1.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 April 2022
Resolution: Crew replaced on the spot.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 24 April 2022
Resolved
Drills shall as far as practicable be conducted as if there were an actual emergency. Fire team did not adequately perform first fire drill or abandon ship drill. Crew was initially unable to start inboard lifeboat.
74 SOLAS (20) III/19.3.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 April 2022
Resolution: Conducted 2nd drill.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 13 October 2021
Resolved
The master, owner, operator, agent, or person in charge of a vessel subject to this subpart and this section must submit a ballast water report to the National Ballast Information Clearinghouse (NBIC). Report not submitted within 6 hours of arrival into U.S. Port.
Action required: 10 - Deficiency Rectified
Due 13 October 2021
Resolved 13 October 2021
Resolution: Report submitted to NBIC.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 September 2021
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The launching mechanism shall be so arranged that it may be actuated by one person from one position on the ship's deck. Port side lifeboat releasing gear is not rigged properly and is not capable of being operated from inside the survival craft. Releasing gear pulley system must be reconnected prior to departure from Port of Boston.
Cite: SOLAS(20) III/34, LSA 6.1.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2021
Resolved 29 September 2021
Resolution: USCG received class report
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 25 September 2021
Resolved
A Passenger Ship Safety Certificate shall be issued after an initial or renewal survey to a passenger ship which complies with the relevant requirements of chapters 11-1, 11-2, III, IV, and V and any other relevant requirements of the present regulations. Liferaft was deployed during the abandon ship drill and needs to be repacked or replaced prior to departure.
Cite: SOLAS(20) I/12.a.i
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2021
Resolved 29 September 2021
Resolution: USCG recieved class report
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 25 September 2021
Resolved
In ships carrying more than 36 passengers, the hull, superstructure and deckhouses shall be subdivided into main vertical zones by "A-60" class divisions. Watertight Door S103 was found with insulation missing behind it.
Cite: SOLAS(20)II-2/9.2.2.1.1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2021
Resolved 25 October 2021
Resolution: Received Satisfactory Class Report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 September 2021
Resolved
Galley roller shutter door must have means of remote (automatic) closure. Galley fire roller shutter cannot be closed from remote location.
Cite: SOLAS(20)II-2/9.4.1.1.5.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2021
Resolved 25 October 2021
Resolution: Received Satisfactory Class Report.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2021
Resolved
Means of escape from control stations, accommodation spaces and service spaces. Provide adequate signage indicating primary and secondary escape routes for all spaces throughout the ship.
Cite: SOLAS(20)II-2/13.3.2.5.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2021
Resolved 25 October 2021
Resolution: Received Satisfactory Class Report.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 September 2021
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. Emergency lighting aft of WTD S101 did not operate under batteries.
Cite: SOLAS(20)II-1/42.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2021
Resolved 25 October 2021
Resolution: Received Satisfactory Class Report.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 September 2021
Resolved
Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler, fire detection and fire alarm system of an approved type complying with the requirements of the Fire Safety Systems Code. A gauge indicating the pressure in the system shall be provided at each section stop-valve and at a central station. While testing sections valves for the water mist system. PSCO observed frozen/inoperable pressure gauges at multiple section valve stations.
Cite: SOLAS(20)II-2/10.6.1, FSS Code 2007 8.2.4.2.5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2021
Resolved 25 October 2021
Resolution: Received Satisfactory Class Report.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 September 2021
Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship. One liferaft on the starboard side was found with the painter rigged incorrectly. Crew rectified deficiency on the spot.
Cite: SOLAS(20)III/20.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 September 2021
Resolved 25 September 2021