MAURY USCG vessel records
← All vessels

ICARIAN STAR

ICARIAN STAR is a 2008 freight ship. The Coast Guard has recorded 28 inspections since 2020, most recently in May 2026, along with 5 deficiencies and 14 operational controls, 1 with no removal date recorded.

Records from 2020 to 2026. Most recent: inspection, 28 May 2026.

Built
2008
Last inspected
28 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 May 2026
…with no type recorded12
Operational controls 1 with no removal date recorded
Years with a record 7 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9437127
1644027
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1644027

Documentation record

Tonnage as PSIX records it18444 - Dead Weight, Ton
25253 - Displacement, Ton
15334 - Convention (Subpart B), Gross Ton
5983 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

28 May 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8383039
28 November 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8274807
27 May 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8144717
26 November 2024 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8039493
24 July 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8011790
16 May 2024 PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7912962
1 May 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7904793
17 April 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7896740
15 April 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7895269
3 April 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7889444
21 March 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7882745
20 March 2024 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7882645
20 March 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7885590
15 March 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7879617
28 December 2023 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7842229
29 September 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7800557
27 June 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7709760
7 June 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7706580
2 December 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7603062
17 November 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7596030
23 August 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7541458
9 August 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7528825
27 July 2022 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7517893
13 July 2022 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7505500
1 June 2022 PSC B · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7463875
17 May 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7452678
16 August 2021 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7288281
21 October 2020 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7078553

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 November 2024 Resolved
Fixed fire-extinguishing systems shall be installed having due regard to the fire growth potential of the protected spaces; and fire extinguishing appliances shall be readily available. PSCO observed 18 of 89 pneumatic CO2 cylinder valves in the fixed firefighting system were observed to have safety pins installed, while the remaining 71 valves were free of safety pins. 74 SOLAS (20) II-2/10.1.1.1-2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2024
Resolved 4 December 2024
Resolution: Class provided details on proper installation of pins in CO2 cylinders and manufacturer justification why safety pins are always installed. The vessel corrected poster with instruction and posted with the manual. crew training conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2024 Resolved
Vessel failed to submit a notice of arrival IAW 33 CFR 160.212(a)(4)(ii).
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 July 2024
Resolved 24 July 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 May 2024 Resolved
Access opening in bulkheads at ends of enclosed superstructures shall be fitted with doors...weathertight when closed. The means for securing these doors weathertight shall consist of gaskets and clamping devices...the doors shall be arranged that they can be operated from both sides of the bulkhead. PSCO observed worn gasket, corrosion, and observed daylight from within ship. Additionally the door was unable to be opened upon initial test of door. ICLL(88)II/12(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 4 June 2024
Resolution: Provided class report, see documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 March 2024 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Port state control officers were notified by vessel agent that the #5 cylinder fuel pump failed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2024
Resolved 21 March 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2020 Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liqufied gas as regulated in Table 4 of 46 CFR part 154 shall provide transfer procedures that meet the requirements of this part and part 156 of this chapter for transferring- (a) To or from the vessel, and (b) from tank to tank within the vessel. Vessel does not have transfer procedures as required by 33 CFR subpart C.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 August 2021
Resolution: Vessel Captain electronically provided transfer procedures and oil system line diagrams.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.