← All vessels
AURA M
AURA M is a 2020 tank ship. The Coast Guard has recorded 7 inspections since 2020, most recently in August 2025, along with 4 deficiencies and 1 operational control.
Records from 2020 to 2025. Most recent: inspection, 5 August 2025.
- Built
- 2020
- Last inspected
- 5 August 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9595333 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5XA2
1644623
Flag
LIBERIA
—
Maury page id
psix-1644623
Inspections, by type
…with no type recorded2
Years with a record
4 calendar years (2020–2025)
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it82374 - Convention (Subpart B), Gross Ton
149999 - Dead Weight, Metric Ton
51078 - Convention (Subpart B), Net Ton
149999 - Dead Weight, Metric Ton
51078 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
5 August 2025
COC-TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8196881
21 October 2023
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7811340
12 October 2023
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7808152
24 September 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7801854
6 February 2022
COC-TVE Annual · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7382317
20 November 2020
COC-TVE Renew · PSC A
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7096028
19 November 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7097268
Deficiency record · 4
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 August 2025
Resolved
IN TANKERS, ELECTRICAL EQUIPTMENT, CABLES, AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATION UNLESS IT CONFORMS WITH STANDARDS NOT INFERIORS TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED 02 CRACKED LENSES EXPLOSION PROOF LIGHT ON PORT SIDE LOCKER.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 24 September 2023
Resolved
Install and operate a ballast water management system (BWMS) that has been approved by the Coast Guard under 46CFRpart 162. The BWMS must be installe in accordance with 151.2035(b) of this subpart. Following installation, the master, owner, operator, agent or person in charge of the vessel subject to this subpartmust properly maintain the BWMS in accordance with all manufacturer specifications.
Vessels BWMS is inoperable.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 20 November 2020
Resolved
In cargo pump rooms a system for continuous monitoring of the concentration of hydrocarbon gases shall be fitted. Fixed gas detection for the pump room was found by the PSCO to be alarming due to a flow-fault failure that was preventing the system from continuously monitoring the atmosphere in the pump room. 74 SOLAS (09), Chapter II-2, Regulation 4.5.10.1.3
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 20 November 2020
Resolved
In tankers, cargo ships shall be fitted with temperature sensing devices for bulkhead shafts, nearings, and pump cases. While conducting the pump room exam, the PSCO found the lower bearing temperature sensor on the number 3 cargo pump disconnected and not able to measure bearing temperature. 74 SOLAS (09), Chapter II-2, Regulation 4.5.10.1.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.