DONGBANG GIANT NO. 3 is a freight ship. The Coast Guard has recorded 3 inspections since 2021, most recently in July 2025, along with 1 deficiency — 1 with no resolution recorded —.
Records from 2021 to 2025. Most recent: inspection, 24 July 2025.
The 3 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it12183 - Convention (Subpart B), Gross Ton 14006 - Dead Weight, Metric Ton 21721 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 3
24 July 2025PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8188015
11 January 2021PSC A · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7118615
4 January 2021Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7119222
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 24 July 2025No resolution recorded
DURING THE MACHINERY INSPECTION, THE TEAM FOUND VESSELS GENERAL CONDITION TO BE SUB-PAR, TO INCLUDE INOPERABLE SMOKE DETECTOR, BROKEN OUTLET BRACKETS, DAMAGED EXTINGUISHER MOUNTS, GROUNDING WIRES FOR LIGHTING, ETC.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.