Records from 2021 to 2025. Most recent: inspection, 3 November 2025.
Documentation record
Registered dimensions (L × B × D)33.0 ft × 10.4 ft × 7.0 ft
Registered tonnagegross 16 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INCORPORATED · ANAHEIM, CA, UNITED STATES · built 1991
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 8 May 2025 · expires 30 June 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 8
3 November 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8259296
22 April 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8106752
22 October 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8019259
26 October 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7809720
29 August 2023
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7776686
18 October 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7562774
15 July 2021
Deficiency Check · Plan Review "T" Boat · COI Inspection · Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7257168
22 April 2021
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7183674
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 November 2025
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Life ring buoy did not have retroreflective tape on it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2025
Resolved 7 November 2025
Resolution: O/O submitted photographic evidence that deficiency has been corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 October 2024
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel had a plastic trash can (waste receptacle) on board, must be replaced with a noncombustible material.
46 CFR 177.405(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 6 November 2024
Resolution: All waste receptacles have been permanently removed from the vessel.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 22 October 2024
Resolved
A vessel must comply with the applicable design, equipment, personnel, procedures, and record requirements of 33 CFR parts 151, 155, and 156. Vessel did not have garbage placard, must obtain and post garbage placard.
46 CFR 184.702
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 6 November 2024
Resolution: Garbage placard was installed on vessel's console.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 October 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel's first-aid kit had expired items inside, operator must replenish expired items.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 6 November 2024
Resolution: First-aid kit replenish with new items.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 October 2024
Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees. Vessel radio MMSI number did not match the MMSI number on the vessel's station license, numbers must match.
47 CFR 80.103(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 6 November 2024
Resolution: MMSI was installed on radio and matched the radio station cert.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 22 October 2024
Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made. Vessel did not have a passenger safety orientation instruction.
46 CFR 185.506(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 6 November 2024
Resolution: MI witness safety orientation.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 October 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Vessel have LED light for it's navigation light, must provide information showing that the LED lights meet the UL 1104 requirement outlined above.
46 CFR 183.420
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2024
Resolved 6 November 2024
Resolution: Rep provided LED specs that showed compliance with Inland Navigation Rules.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2021
Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Shutoff valve under the engine hatch is not shielded from flames, must install shield to adequately protect hands while reaching into space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Installed remote fuel shut-off, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The fuel racor filter is missing the metal flame shield. Must install flame shield.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Installed flame shield.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2021
Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. The fuel fill neck is not bonded to the tank. Must install suitable bonding strap from the tank to the fill neck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Installed bonding strap.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 July 2021
Resolved
Vessel required to have approved plans for the electrical, mechanical installation. Vessel approved drawings do not match installation. Make corrections, submit drawings for approval and conduct verification with attending marine inspection to demonstrate that installation matches the approved drawings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2021
Resolved 9 January 2023
Resolution: Verified all drawings approved and vessel mirrors drawings, see activity #7562774 for details