NIKE is a 2021 towing vessel. The Coast Guard has recorded 4 inspections since 2021, most recently in June 2025, along with 4 deficiencies.

Records from 2021 to 2025. Most recent: inspection, 4 June 2025.

Built
2021
Last inspected
4 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 4 June 2025
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2021–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9934967
WDM5064
1646882
Flag
UNITED STATES
Maury page id
psix-1646882

Documentation record

Registered dimensions (L × B × D)93.1 ft × 43.4 ft × 15.6 ft
Registered tonnagegross 299 / net 203
ITC dimensions (L × B × D)93.1 ft × 43.4 ft × 15.6 ft
ITC tonnagegross 484 / net 145
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2021
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT EVERGLADES, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 July 2025 · expires 31 August 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it484 - Convention (Subpart B), Gross Ton
299 - Regulatory (Subpart C or D), Gross Ton
145 - Convention (Subpart B), Net Ton
203 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 4

4 June 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8152241
15 October 2024 Administrative Inspection · Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8020680
28 June 2024 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7944247
4 February 2021 Administrative Inspection · Construction Oversight · Initial Certification · Plan Review (Other than "T") · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7333655

Deficiency record · 4

08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 18 October 2021 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or essential system develops problems that require attention. Alarms must be visible and audible at each operating station. System is in continuous alarm at the operating station, therefore MI's unable to verify proper audible alarm function at the operating station. 46 CFR 143.230(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2021
Resolution: Cleared on COI inspection
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 October 2021 Resolved
The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience, to comply with paragraphs (a)(1) through (6) of this section. MI's unable to verify system and its installation on the towing vessel certified and inspected by qualified entity, objective evidence was not available for verification. 46 CFR 142.330(a)(7)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2021
Resolution: Cleared on COI inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 18 October 2021 Resolved
A safety management system (SMS) which is fully compliant with the International Safety Management (ISM) Code requirements, implemented in 33 CFR part 96, will be deemed in compliance with TSMS-related requirements in this subchapter. Vessel does not have SMC. 46 CFR 138.225(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2021
Resolution: Cleared on COI inspection
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 18 October 2021 Resolved
If the cognizant OCMI has reasonable cause to believe that a vessel's survey program is deficient, that OCMI may; require an audit or survey of the vessel in the presence of a representative of the cognizant [name withheld] received survey report on 10/18/21 that the vessel had been surveyed on that date with no non-conformities. MI's attended same day for COI and found deficient items hours after TPO attendance and items on survey that were not accurate. 46 CFR 137.212(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2021
Resolution: Cleared on COI inspection

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.