This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it2897 - Convention (Subpart B), Gross Ton 4037 - Dead Weight, Ton 5964 - Displacement, Ton 1238 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
16 December 2020Deficiency Check · PSC A · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7109165
12 December 2020Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7110804
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 December 2020Resolved
The vapor collection system must have a means to drain condensation at a low point in the line. Vessel's VCS does not have a drain line.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 December 2020
Resolved 31 December 2020
Resolution: Class report submitted. Class Confirmed the installation of a drain line in the VCS.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 December 2020Resolved
There must be a manual isolation valve for the vapor collection system at the vapor connection with indication that the valve is open or closed. vessel does not have a manual isolation valve for VCS at the manifold.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 December 2020
Resolved 31 December 2020
Resolution: Class report submitted. Class Confirmed the installation of a isolation valve in the VCS.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 December 2020Resolved
Foreign vessels may submit certification by the classification society that certifies vapor collection systems are approved by 46 CFR 39. Vessel's approved VCS manual and system drawing do not match the constructed configuration of the VCS onboard.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 December 2020
Resolved 31 December 2020
Resolution: Class report submitted. Class Confirmed the correction of VCS drawings.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.