WENDY JO

Built
1978
Last inspected
11 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 11 February 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1995–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ3632
164979
Flag
UNITED STATES
Maury page id
psix-164979

Documentation record

Registered dimensions (L × B × D)71.2 ft × 26.0 ft × 10.2 ft
Registered tonnagegross 85 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAIN IRON WORKS INC · BAYOU BLUE, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLONG BEACH, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 13 November 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it85 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CP 45 Freight Barge · MISLE 497650 · 27 February 2016 · activity 5833238CP 45 Freight Barge · MISLE 497650 · 9 January 2006 · activity 2563785LMC DUMP SCOW 35 Freight Barge · MISLE 48320 · 4 March 1998 · activity 104701CP 40 Freight Barge · MISLE 50017 · 4 March 1998 · activity 104701

Inspection history · 22

11 February 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8265226
15 July 2025 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8186545
27 March 2025 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8100290
21 November 2024 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8026705
25 October 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024892
17 June 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7879241
30 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7694304
14 December 2022 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7609294
29 March 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7415610
22 July 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7380936
27 February 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5833238
20 July 2015 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5190504
2 July 2013 Industry Initiated Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4640010
1 March 2011 Industry Initiated Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3955096
8 January 2007 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2852529
9 January 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2563785
19 January 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2277179
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977702
21 April 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 6067
4 March 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 104701
16 June 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 195720
16 June 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754327

Deficiency record · 28

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 February 2026 Resolved
There must be an installed or portable bilge pump for emergency de-watering. Any portable pump must have sufficient hose length and pumping capability. Ships crew was unable to get Engine room aft bilge suction line to make suction due to faulty isolation valve. Make bilge line fully operational and make available to attending marine inspector. action code 705 Prior to towing operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2026
Resolved 12 February 2026
Resolution: Witness proper operation of AFT Bilge suction. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 February 2026 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. MI observed leak off the PORT MDE lube oil filter manifold. Fix leak and make available for inspection to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2026
Resolved 25 February 2026
Resolution: Ships crew replaced filter manifold. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 11 February 2026 Resolved
Each towing VSL operating in Oceans and coast wise service must have a line throwing appliance approved under approval series 160.040. MI observed line throwing device and auxiliary lines were expired. Procure new Line throwing devices.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2026
Resolved 12 February 2026
Resolution: O/O operator procurred new line throwing devices. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 February 2026 Resolved
Each towing vessel must be equiped with navigation lights, shapes, and sound signals in accordance with the international regulations for prevention of collisions at sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. MI observed anchor light inoperable. Repair or replace anchor light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2026
Resolved 25 February 2026
Resolution: Ships crew replaced anchor light. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 February 2026 Resolved
Safety orientations and other crew training must be documented in the TVR, or official logbook. Ship was unable to provide documentation on crew members required safety orientation and ship specific training. Provide documentation and attestation to crew members ship specific and required training as per 46CFR140.410(a)-(d).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2026
Resolved 25 February 2026
Resolution: O/O created crew training log and had all applicable crew members review and sign. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 February 2026 Resolved
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crew members. Station bill with required positions and emergency responsibilities was not posted anywhere on the VSL. Create and post emergency station bill in a conspicuous location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2026
Resolved 25 February 2026
Resolution: O/O created Station Bill with required positions for crew during emergencies. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 27 March 2025 Resolved
MI found several spots in hull plating of the engine room that had multiple clad welds. Provide a detailed drawing of the engine room bilge showing the locations of all clad weld. Also, provide a gauging report of the hull plating that contains clad weld to local OCMI.
Action required: 705 - Other - as specified
Resolved 14 July 2025
Resolution: MI attended vessel to look at repairs. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI identified leaks from the fuel oil filters on both port and starboard main engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 6 February 2025
Resolution: Fuel oil filter manifold was replace, no visible leaks when operating.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 November 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI identified minor leaks on the steering gear hydraulic rams.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 6 February 2025
Resolution: Vessel repaired one hydraulic ram and replaced the other, operating with no visible leaks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed the following unsafe electrical installations: The bridge breaker panel was missing proper labeling, and multiple dead-end exposed wiring were observed on 2nd deck exterior bulkhead above cylinders, under the bridge conning station and in battery charger in storage space under bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 6 February 2025
Resolution: All electrical was terminated or repaired properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2024 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. MI identified potable water pump plugged in to outlet rather than hardwired in enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 6 February 2025
Resolution: Water pump was hardwired to electrical recepticle.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2024 Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of § 142.225 of this subchapter. Plastic trash receptacles (03) were located in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 6 February 2025
Resolution: ALl trash cans in the engineering space have been replaced with non combustible trash cans.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 May 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. MI found Port and Stbd shaft seal leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 15 June 2023
Resolution: Recieved video. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. MI found Port and Stbd Main Diesel Engine with excessive lube oil leaking from the filter housing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 15 June 2023
Resolution: Recieved video. All sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 March 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Inspector identified a hydraulic leak from the aft deck port side steering unit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2022
Resolved 14 December 2022
Resolution: Operator submitted photo of new hydraulic fitting installed that does not leak.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 29 March 2022 Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Inspector found that the vessel lacked the required number of line throwing components as set forth by 160.040. The vessel had only one full complement of components. The following should be placed on board the vessel: Four Service Lines, Four Rocket Projectiles and Four Primer-Ejector Cartridges. A) At least four Rocket Projectiles; each projectile must have a fire resistant bridle and leader (two of the projectiles shall be buoyant). B) At least four primer-ejector cartridges fitting the chamber of the pistol, gun or launcher. C) At least four “Service Lines” of 4mm minimum diameter and 500 pounds breaking strength. The length of each “Service Line” is determined through testing and equipped by the manufacturer. Each line shall be coiled, faked, or reeled in its own faking box or reel. D) An “Auxiliary Line” of at least 1500 feet in length with a breaking strength of not less than 9,000 pounds and resistant to UV deterioration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Vessel submitted photo of rocket projectiles and 1500' auxiliary line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2022 Resolved
Relief valves must be tested in accordance with 143.245 (Twice every five years, with no more than three years elapsing since last test). Inspector found that relief valves had not been tested within the required time frame.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Vessel has replaced the relief valve with a new one that has been tested and calibrated.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 29 March 2022 Resolved
The owner, managing operator, master or officer in charge of a navigation watch of a towing vessel must ensure the strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. Inspector found that the airlines for the towing gear winch were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Vessel has replaced the deteriorated air line that now properly functions.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 29 March 2022 Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Inspector found that the protective globe for the top bunk light within the crews missing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Operator submitted photo of installed protective housing for light in crew berthing.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 March 2022 Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Inspector found that the electrical outlet within the crew head had reversed hot/neutral wires.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Vessel has re-wired and replaced faulty electrical outlet. Outlet now functions properly.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 March 2022 Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. Inspector found that not all crewmembers had participated in the required monthly schedule.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Vessel has submited satisfactory documentation that drills are being conducted as per requirements.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 29 March 2022 Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing duties during an emergency to include (1) abandoning the ship (2) recovering persons from the water, (3) responding to flooding, (4) responding to other threats to life, property or the environment. Inspector found that not all crewmembers had participated in the required drills/instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Vessel has submitted satisfactory documentation that the drills are being conducted as per the requirements.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 29 March 2022 Resolved
Closure devices must be provided for deckhouse or hull penetrations which open to the exterior or the vessel and which may allow water to enter the vessel. Inspector found nonfunctional dogs on the port holes within the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Inspector submitted photo of functioning dogs from porthole.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 29 March 2022 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards including safe food handling. Inspector found that a protective rail/guard was not installed on the stove-top to prevent the shifting of cooking ware (pots/pans,etc.) while underway.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Operator submitted photo of protective guard around stovetop.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 March 2022 Resolved
Each towing vessel must be equipped with navigation lights in accordance with COLGREGS or 33 CFR part 84 as appropriate to the area of operation. Inspector found a broken bulb installed in the lower tow light on the masthead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 29 March 2022
Resolution: Operator replaced the broken bulb.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 March 2022 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Grounding cable terminal for battery chargers was found sheared off from bulkhead in engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Operator submitted photo of repaired grounding cable terminal.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 March 2022 Resolved
Fire hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. Fire hoses onboard were not lined commercial fire hose.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Operator submitted photo of installed UL commercial lined fire hose.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 March 2022 Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. Fire alarm in engine room was damaged during testing rendering the fire detection system inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 14 December 2022
Resolution: Operator replaced fire detector in the engine room and verified that the system is now operable.

Recorded names · 1

LARCONA (2006–2021). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.