← All vessels
BAHAMAS PEARL
BAHAMAS PEARL is a freight ship. The Coast Guard has recorded 20 inspections since 2024, most recently in July 2026, along with 28 deficiencies and 6 operational controls.
Records from 2024 to 2026. Most recent: inspection, 3 July 2026.
- Built
- Not recorded
- Last inspected
- 3 July 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 28 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9356347
HOA5301
1650081
Flag
PANAMA
Maury page id
psix-1650081
Inspections, by type
…with no type recorded5
Years with a record
3 calendar years (2024–2026)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it949 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 20
3 July 2026
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8426759
22 February 2026
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8313964
17 January 2026
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8297698
15 January 2026
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8296935
12 December 2025
Deficiency Check · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8282062
6 June 2025
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8153443
23 May 2025
PSC A · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8140456
26 April 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8120439
9 April 2025
PSC A · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8108204
20 March 2025
PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8096677
10 January 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8060932
2 January 2025
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8056908
4 October 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8011703
24 September 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8008386
31 August 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7992031
10 June 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7929963
23 May 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7917590
3 May 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7906043
16 March 2024
PSC A · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7872647
11 March 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7877189
Deficiency record · 28
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 July 2026
Resolved
The following tests and inspections shall be carried out weekly and a report of the inspection shall be entered in the logbook: all engines in lifeboats and rescue boats shall be run for a total period of not less than 3 min provided the ambient temperature is above the minimum temperature required for starting and running the engine. PSCO's observed the fuel line broke to the rescue boat engine and crew was not conducting/recording weekly inspections.
74 SOLAS(20) III/20.6.2
Code 17
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 July 2026
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. Observed lube oil leaking from STBD main propulsion engine from the seal of the connected hydraulic steering pump.
74 SOLAS(04) II-1/26.1
Code 17
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 January 2026
Resolved
A main source of electrical power of sufficent capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. PSCO observed 1 of the 2 main DGs inop. Vessel in conjunction with the Flag placed a portable power pack onboard and implemented mitigation measures.
74 SOLAS (04) II-I/41.1.1
Code 16
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 12 December 2025
Resolved
Cargo ships shall carry at least one rescue boat complying with the requirements of section 5.1 of the Code.
PSCO observed an inoperable search light and missing thermal protective aids as required in all rescue boats. In addition, the inflated rescue boat is missing the required repair kit.
74 SOLAS (20) III/31.2
LSA 5.1.2.2
LSA 5.1.2.3
Code 16
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 12 December 2025
Resolved
Ad adequate system of ventilating crew accomodation shall be provided. PSCO observed inoperable ventillation in the water closet on the main deck.
46 USC 70002
ILO 147, pg. 33
Code 16
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 12 December 2025
Resolved
Ther machinery... associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended...PSCO observed excessi e leaking of hydraulic oil from foward mooring and ramp winches at hose connection points.
74 SOLAS (04) II-1/26.1
Code 16
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2025
Resolved
General arrangement plans shall be permanently exhibited... showing clearly for each deck the control stations, the carious fire sections enclosed by "A" class divisions, the sections enclosed by "B" class divisions... Plans... shall be kept up to date; any alternations thereto shall be recorded as soon as practicable. PSCO observed the two doors in the galley as well as the both doors in the stairwell between the main deck and the accomodation deck do not meet the "A" class boundary requirements as prescribed by the ship's fire control plan.
74SOLAS(20) II-2/15.2.4.1
Code 50
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 December 2025
Resolved
... launching and embarkation appliances complying with the requirements of section 6.1 of the Code shall be provided for all survival craft...PSCO observed that the rescue boat davit does not have a limit switch as required.
74 SOLAS (20) III/16.1
LSA 6.1.2.7
Code 50
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 May 2025
Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard paying to moving parts, hot surfaces, and other hazards. The design shall have regards to materials used in construction, the purpose for which the equipment is intended... PSCOs observed port engine failed to secure with stop switch.
74SOLAS(20) II-1/26.1
Code 17bc
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 May 2025
Resolved
It shall be possible to control the propulsion machinery locally, even in case of failure in any part of the remote control system. PSCOs observed local steering control on port azipod not operable.
74SOLAS(20) II-1/31.2.6
Code: 17bc
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 April 2025
Resolved
Where air pipes to ballast and other tanks extend above the freeboard or superstructure decks, the exposed parts of the pipes shall be of substantial contruction. PSCOs observed port side air pipes to fuel oil tanks to not be of substantial construction due to allision in last port.
ICLL 66 Annex I/Reg.20
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 March 2025
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the objective evidence in the below deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. PSCOs collected objective evidence that the vessel could not produce evidence that the company notified Flag Administration of the serious safety deficiencies, IBS acted on behalf of flag without administration approval. External audit required.
74 SOLAS (2020) IX/3.1
ISM Code A/10.1
Code 30bc
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 20 March 2025
Resolved
A certificate called a Cargo Ship Safety Construction Certificate shall be issued after an initial or renewal survey to a cargo ship which complies with the relevant requirements of Chapters II-1 and II-2 (other than those relating to fire safety systems and appliances and fire control plans) and any other relevant requirements of the present regulations. PSCOs found SOLAS Safety Construction Certificate expired on January 20, 2025.
74 SOLAS (2020) I/12(a(ii)
Code 30bc
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCOs observed an unauthorized power pack with portable fuel tank on the main deck. The crew stated the power pack is used as the vessel’s main service generator while in port.
74 SOLAS (2004) II-1/41.1.1
Code 17bc
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 March 2025
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. PSCOs observed 2nd generator set is inoperable.
74 SOLAS (2004) II-1/41.1.1
Code 17bc
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 March 2025
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCOs observed portable power pack from main deck feeding a live cable to the main service electrical swith board.
74 SOLAS (2004) II-1/45.1.3
Code 17bc
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 January 2025
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed broken piping on port side main deck exposing electrical wiring.
74 SOLAS 04 CH II/1/45.1.3
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 January 2025
Resolved
Electrictal services essential for safety will be ensured under various emergency conditions. PSCO observed broken latch used for operating ventilation in the emergency diesel generator space.
74 SOLAS 04 CH II-1/20.2
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 31 August 2024
Resolved
"A minimum of two inspections of the outside of the ship's bottom during any five-year period except where regulation 14(e) or (f) is applicable, this five-year period may be extended to coincide with the extended period of validity of the certificate. In all cases the interval between any two such inspections shall not exceed 36 months;"
PSCO observed last two inspections of the ship's bottom documented on the cargo ship safety construction certificate are 22MAY2020 and 16JAN2024, thus not meeting the requirement to be within 36 months of each other.
74SOLAS(20)Ch.I,Reg.10(a)(v)
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 10 June 2024
Resolved
Ships shall be provided with independently driven fire pumps as follows: in cargo ships of less than 1,000 gross tonnage at least two power driven pumps, one of which shall be independently driven.PSCO's observed emergency fire pump was not bulding pressure.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 10 June 2024
Resolved
Adequate information shall be provided to enable the equipment to be properly maintained, operated taking into action the recommendation of the organization. PSCO's observed the GMDSS log book didnt have entries sincde May 2024.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 1 April 2024
Resolved
A duplicate set of fire control plans or a booklet stored in a prominently marked weathertight enclosure outside the deckhouse for the assistance of shore- side fire fighting personnel. PSCOs observed no fire control plan stored in a weathertight enclosure outside the deckhouse.
74 SOLAS (04) II-2/15.2.4.2
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 April 2024
Resolved
Machinery spaces of category A containing internal combustion machinery shall be provided with one of the fixed fire-extinguishing systems in paragraph 4.1. PSCO's observed two internal combustion engines located outside of a category A machinery space. That are used for the main propulsion of the vessel. PSCO's observed no fixed fire-extinguishing system and no approved alternative design or arrangements.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 March 2024
Resolved
Every inflatable life raft...shall be serviced at intervals not exceeding 12 months...
PSCO's observed the rescue boat and all 04 liferafts have not been serviced in over 12 months. All servicing is expired.
74 SOLAS (20) III/20.8.1.1.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 March 2024
Resolved
Any main and auxiliary steering gear control system operable from the navigation bridge shall comply with the following... The system shall be capable of being brought into operation from a position on the navigation bridge...
PSCO's observed starboard main diesel engine/ steering drive gear inoperable from the navigation bridge.
74 SOLAS (20) II-1/29.8.2.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 16 March 2024
Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the following ballast water management methods: install and operate a ballast water management system that has been approved by the Coast Guard.... Use only water from the United States public water system...Perform complete ballast water exchange in an area 200NM from any shore prior to discharging ballast water...Do not discharge ballast water into the waters of the United States...Discharged a facility onshore or to another vessel for purposes of treatment....
PSCO's observed expired ballast water management certificate with inaccurate treatment methods.
33 CFR 151.2025
14 - Pollution Prevention › 148 - Ballast Water › Ballast water logs/records
Issued 16 March 2024
Resolved
...Maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible... To understand and follow the vessel's ballast water management strategy...
PSCO's observed vessel ballast water management plan was not specific to the vessel and did not accurately reflect ballast water treatment plan on board.
33 CFR 151.2050 (G)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2024
Resolved
Accumulator batteries shall be suitably housed.
PSCO's observed accumulator battery in emergency fire pump room on forward port side was not housed.
74 SOLAS (20) II-1/45.9.1.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.