ODYSSEY OF THE SEAS

ODYSSEY OF THE SEAS is a 2021 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2021, most recently in November 2025, along with 6 deficiencies and 1 operational control.

Records from 2021 to 2025. Most recent: inspection, 5 November 2025.

Built
2021
Last inspected
5 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2021–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9795737
1651206
Flag
BAHAMAS, THE
Maury page id
psix-1651206

Documentation record

Tonnage as PSIX records it167704 - Convention (Subpart B), Gross Ton
166807 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

5 November 2025 COC-CVE Annual · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8264284
17 November 2024 COC-CVE Annual · Administrative Inspection · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8034147
11 November 2023 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7820928
6 November 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7820887
15 December 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7609422
13 November 2022 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7593342
15 January 2022 PSC B · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7379899
18 July 2021 COC-CVE Initial · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7219338
7 June 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7218172
7 June 2021 Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7218216

Deficiency record · 6

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 November 2025 Resolved
The Load line ring, lines and letters shall be painted white or yellow on a dark background or in black on a light background. They shall also be permanently marked. PSCO observed the Load Line mark not painted in contrasting colors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2025
Resolved 10 November 2025
Resolution: Received pictures and documentation from Class attesting the rectification of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 November 2025 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they fitted. PSCO observed self-closing door leading to category 2 escape trunk not fully closed compromising the boundary.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 November 2025
Resolution: Door was adjusted to properly closed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 November 2025 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or wher it is possible to assgin two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed loose oxygen bottles in AC room adjacent to EDG room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 5 November 2025
Resolution: Oxygen bottles were moved to a moe suitable location.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 November 2025 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersectios. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additionaly, escape route signs and fire equipment location markings shall be of photoliminescent material or marked by lighting. PSCO observed defective low location lighting by crew barber P/S corridor on deck 3.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 November 2025
Resolution: Low location lighting section was fixed on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 July 2021 Resolved
Aids for escape shall be provided as necessary to ensure accessibility, clear marking, and adequate design for emergency situations. Inadequate emergency signage found in the boiler room and uniform shop to facilitate escape from the space. Additional exit signage required for both boiler and uniform shop.
Action required: 10 - Deficiency Rectified
Resolved 18 July 2021
Resolution: Vessel Safety Officer provided extra escape route signage for both spaces. PSCO's verified new signage was added.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 July 2021 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials...the following functional requirements shall be met: ignitability of combustible materials shall be restricted. Remove stowage of combustibles from the converter room.
Action required: 10 - Deficiency Rectified
Resolved 18 July 2021
Resolution: Engineering crew removed combustible materials from the converter room, PSCO verified.