GOLD RUSH

GOLD RUSH is a 1980 passenger vessel (inspected). The Coast Guard has recorded 4 inspections since 2022, most recently in April 2025, along with 5 deficiencies.

Records from 2022 to 2025. Most recent: inspection, 8 April 2025.

Built
1980
Last inspected
8 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 April 2025
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2022–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN5305
1652729
Flag
UNITED STATES
Maury page id
psix-1652729

Documentation record

Registered dimensions (L × B × D)52.0 ft × 16.5 ft × 8.1 ft
Registered tonnagegross 46 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT LLC · WESTPORT, WA, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 18 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

8 April 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8106835
18 September 2024 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8003681
23 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7899859
13 July 2022 Plan Review "T" Boat · Deficiency Check · Simplified Stability Test · Initial Certification · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7505764

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 April 2024 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. The vessel did not have trash cans on board made out of noncombustible material.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 23 April 2024
Resolution: Vessel sent satisfactory photo showing metallic trash can onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2024 Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. The life ring buoy on board was splitting at the seam and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 2 May 2024
Resolution: Vessel rep sent satisfactory evidence of new life ring buoy on board.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 April 2024 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. The container on board was not a bright color. Replace to the satisfaction of the marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 23 April 2024
Resolution: Vessel sent satisfactory photos showing bright orange flare container.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of each portable fire extinguisher. The vessel had 01 portable fire extinguishers on board not maintained with an expired servicing tag. Removed in the presence of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 April 2024
Resolution: Vessel removed expired portable fire extinguisher in the presence of the marine inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 April 2023 Resolved
Independent fuel tanks over four hundred gallons must be designed with a factor of safety of four. In lieu of fuel tanks meeting a factor of safety of four, vessel must install; amended sounding stick, electronic fuel gauge and safety placard at fueling station as described in approval of special consideration. Prior to installation vessel shall not refuel and is approved to carry passengers until 14APR23. 46 CFR 182.440(a)(1)note 2
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 May 2023
Resolution: Attended to inspect fuel gauge. All sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.